Overview
DMP 1112 Water and Temperature Detector
DMP 1112 Water and Temperature DetectorThe DMP 1112 is a combined water and temperature detection sensor designed for facility protection and environm…
DMP 1112 Water and Temperature Detector
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
DMP 1112 Water and Temperature Detector
The DMP 1112 is a combined water and temperature detection sensor designed for facility protection and environmental monitoring in security and building automation applications. This dual-function detector identifies both water intrusion and temperature anomalies, making it suitable for deployment in data centers, server rooms, mechanical spaces, and other critical infrastructure environments where environmental conditions require continuous oversight.
Overview
Water damage and temperature excursions represent significant operational risks in facilities housing sensitive equipment, cabling infrastructure, and climate-controlled spaces. The DMP 1112 addresses both threats with a single integrated sensor platform. Detection signals can be integrated into existing security control panels and building management systems, enabling automated response protocols when water or temperature thresholds are breached.
Key Features
- Dual-function detection: simultaneous water and temperature sensing in a single compact device
- Water detection capability identifies pooling, pipe leaks, condensation overflow, and other moisture intrusion scenarios
- Temperature monitoring alerts facility operators to HVAC failures, equipment overheating, or freeze conditions
- Integration with standard security control panels and BMS platforms via conventional alarm signaling
- Compact form factor for discreet installation in rack spaces, under-floor deployments, or above ceiling areas
- Low-voltage operation suitable for distributed sensor architectures in multi-zone facilities
- Reliable solid-state sensing with minimal false-alarm rates in stable environmental conditions
- Extended cable connectivity allows remote placement away from control equipment
Integration & Compatibility
The DMP 1112 functions as a conventional zone input device, connecting to any control panel equipped with supervised or unsupervised alarm inputs. Installers can assign water detection and temperature detection outputs to separate zones, allowing independent alarm response logic. This flexibility supports tiered alerting—for example, a water-detect alarm may trigger an immediate facility notification, while a temperature threshold may log data for trend analysis or trigger HVAC restart sequences.
In security-first deployments, the DMP 1112 can be incorporated into broader environmental monitoring strategies alongside motion detectors, door contacts, and other facility sensors. In building automation contexts, the device feeds data to HVAC and facility management software, automating equipment shutdown or containment measures in response to detected threats.
Deployment Considerations
Proper placement of the DMP 1112 is critical for effective water detection. Position sensors in areas prone to moisture: beneath water supply lines, around HVAC condensate drains, under hot water heaters, and in equipment room floors. For temperature monitoring, locate the unit in the space whose conditions are most representative of the environment being protected. Cable runs should be rated for the installation environment and protected from physical damage in accessible areas.
The 1112 supports both hardwired and extended-run installations, accommodating facility layouts where control panels are distant from monitored zones. Standard security wiring practices and supervision protocols apply.

I've specified the DMP 1112 in several server and data center refresh projects where environmental monitoring was mandated but existing infrastructure lacked comprehensive sensing. The 1112's dual-function design eliminated the need to deploy separate water and temperature devices, reducing panel inputs and installation complexity.
Technical Highlights:
- Dual Detection: Single sensor addresses both water intrusion and temperature deviation, simplifying commissioning and reducing false-alarm vectors
- Panel Agnostic: Works with any control system accepting conventional alarm zone inputs—no proprietary gateways or special modules required
Deployment Considerations:
- Water detection sensitivity can be field-verified before final installation; place test drops to confirm alarm behavior at intended thresholds
- Temperature offset tuning may be necessary if the 1112 is mounted in a location that doesn't accurately represent the monitored space; account for radiant heat or draft exposure during sensor placement
The DMP 1112 delivers straightforward, reliable environmental protection without vendor lock-in. It's particularly valuable in retrofit scenarios where adding smart building integration is desirable but existing control architecture must be preserved.
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology