APC by Schneider Electric
SKU: APDU10250SM
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU11250SM is a 0U three-phase rack PDU engineered for high-density data center and network equipment rooms where per-outlet switching, outlet-level metering, and remote management are non-negotiable. Rated at 11.5 kW across a 415V, three-phase input, it handles serious power loads — the kind you encounter in fully loaded rack PDU deployments running blade servers, storage arrays, or dense networking infrastructure. With 42 outlets spanning four outlet types and five Ethernet management ports, this unit is built for environments where power visibility and remote control matter as much as raw capacity.
The NMC3 management platform sets the APDU11250SM apart from basic metered PDUs: you get per-outlet switching, real-time outlet-level metering, and remote management through a dedicated out-of-band network interface — so a misbehaving server can be power-cycled without touching the rack or dispatching a technician. That capability translates directly to reduced mean-time-to-recovery in co-location environments and remote edge deployments where hands-on access is expensive or impossible.
The APDU11250SM integrates with APC by Schneider Electric's EcoStruxure IT infrastructure management ecosystem via the NMC3 platform, enabling centralized monitoring, alerting, and automated load management across multiple PDUs. The five Ethernet ports support integration into existing SNMP-based data center infrastructure management (DCIM) platforms. The C13, C15, C19, and C21 outlet mix accommodates standard IEC power cords used across server, storage, and network switch hardware from virtually all major vendors. At 400V three-phase input, the unit requires appropriate three-phase power infrastructure — verify your rack's power feed matches before specifying this model in single-phase environments.
Q: What outlet types does the APDU11250SM provide?
A: The APDU11250SM provides 42 total outlets across four IEC connector types: C13, C15, C19, and C21. This mix covers standard servers and switches (C13/C19) as well as higher-temperature-rated applications (C15/C21), allowing a single PDU to serve a mixed-equipment rack without adapter cables.
Q: What is the input voltage and phase requirement for the APDU11250SM?
A: The APDU11250SM requires a three-phase input at 400V nominal (415V rated) with a maximum current of 60A. It accepts both 50 Hz and 60 Hz input frequencies. This unit is not compatible with single-phase power feeds — confirm your rack's power infrastructure before ordering.
Q: How does the NMC3 management platform differ from basic PDU management?
A: NMC3 provides per-outlet switching and metering over a dedicated out-of-band network interface with support for SNMPv3, HTTPS, and modern authentication protocols. Unlike basic metered PDUs that only report aggregate load, NMC3 enables remote power cycling of individual outlets, real-time per-outlet current monitoring, and integration with DCIM platforms — without requiring physical access to the rack.
Q: Does the APDU11250SM occupy rack units (U) inside the cabinet?
A: No. The APDU11250SM is a 0U (zero rack unit) PDU, meaning it mounts vertically along the side or rear of the rack and does not consume any horizontal rack unit slots. All 42U of equipment space in the cabinet remains available for compute or network hardware.
Q: Is the APDU11250SM RoHS compliant?
A: Yes. The APDU11250SM carries RoHS certification, confirming it meets EU restrictions on hazardous substances. This is relevant for EU deployments and for organizations with environmental or sustainability-based procurement policies.
Q: Can the APDU11250SM be used with single-phase power distribution?
A: No. This PDU is designed exclusively for three-phase power infrastructure at 400–415V. If your facility uses single-phase distribution or North American 208V three-phase, a different PDU model in the APC Netshelter family would be required.

When I look at the APDU11250SM, the spec that immediately stands out is the 34,600 VA load capacity at 60A across a 415V three-phase input. That's not a PDU you spec for a light-duty equipment closet — that's a unit for high-density compute racks where every outlet is loaded and every watt is accounted for. The combination of 42 switched metered outlets and NMC3 makes this a serious infrastructure management tool, not just a power strip.
Technical Highlights:
Deployment Considerations:
The APDU11250SM is the right call for international co-location facilities, enterprise data centers running European power infrastructure, or any high-density rack environment where remote outlet-level control and per-outlet metering need to coexist in a zero-U footprint.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price