Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: APDU10250SW
UPC: 731304439691
Condition: New
Write a Review 32% OFF

APC Netshelter Rack PDU Advanced Switched 11.5KW 3PH 415V 20A 520P6 42 OU - APDU10250SW

APC by Schneider Electric APDU10250SW Advanced Switched 3-Phase Rack PDUOverviewThe APC by Schneider Electric APDU10250SW is an 11.5KW, 3-phase, 415V …

$4,055.00 $2,747.99 SAVE $1307
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter Rack PDU Advanced Switched 11.5KW 3PH 415V 20A 520P6 42 OU - APDU10250SW

$4,055.00
$2,747.99

Overview

SKU: APDU10250SW
UPC: 731304439691
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU10250SW Advanced Switched 3-Phase Rack PDU

Overview

The APC by Schneider Electric APDU10250SW is an 11.5KW, 3-phase, 415V switched rack PDU built for high-density data center and server room deployments where per-outlet power control is not optional — it is operational infrastructure. The 520P6 input plug and 42-outlet configuration make it a natural fit for fully loaded enterprise racks carrying compute, storage, or networking gear that cannot tolerate uncontrolled restarts or shared-circuit ambiguity. At 149.0 cm (58.66 in), this is a full-length 0U vertical unit designed to mount in the rear channel of a standard EIA-310 cabinet, keeping outlet density high without consuming rack units. Browse the full APC by Schneider Electric power management catalog for complementary infrastructure options.

Key Features

  • Switched PDU Architecture — Per-Outlet Remote Control: As a switched PDU, each outlet can be independently energized, de-energized, or power-cycled remotely. For a data center operator managing servers across multiple racks, this eliminates the need for a technician on the floor to hard-reboot a hung device — a measurable reduction in mean time to restore during off-hours incidents.
  • 11.5KW / 3-Phase / 415V Input — Dense Rack Support: Three-phase power distribution at 415V keeps per-phase current lower than single-phase equivalents at the same wattage, reducing conductor heating and improving load balancing across the facility's panels. At 11.5KW total capacity, a fully loaded rack of 1U servers or blade infrastructure can draw confidently without approaching the circuit breaker threshold.
  • 20A Input Rating with 520P6 Plug — Direct Panel-Feed Compatibility: The 520P6 input connector matches standard 3-phase 20A feeds common in European and international data center builds. Verify your facility's whip termination before ordering — this is not a C19/C20 or L21-20 input device.
  • 42 Outlets — High-Density Device Population: 42 outlets across a single PDU supports a fully-populated rack without daisy-chaining or adding a second PDU. Each outlet under switched control means 42 independently controllable power points — relevant for mixed-role racks running cameras, NVRs, edge compute, and storage in a converged security infrastructure.
  • 1.8m (5.9 ft) Cord Length — Flexible Top-of-Rack or Bottom-Feed Routing: A 1.8-meter input cord provides enough slack to reach a PDU whip or floor-level power strip from either end of a standard 42U or 45U cabinet without strained connectors or forced cable routing around adjacent equipment.
  • 50/60 Hz Dual-Frequency Acceptance — Multi-Region Deployability: The unit accepts both 50 Hz and 60 Hz input, allowing procurement teams to standardize on one SKU across facilities in North America, Europe, and Asia-Pacific without frequency-specific procurement splits.
  • 7.2 kg (15.9 lb) — Tool-Assisted Install Recommended: At 149 cm and 7.2 kg, this PDU requires a second person or a lift during vertical rail installation. Plan the install sequence — mount the PDU before populating the rack for easiest positioning.

Integration and Compatibility

The APDU10250SW is part of APC's NetShelter rack PDU line, engineered to integrate with APC's EcoStruxure IT infrastructure management platform for monitoring, alerting, and remote switching via network interface. For full remote management, a separately purchased network management card (NMC) or the integrated network port (verify per SKU configuration) connects the PDU to your DCIM or BMS. Pair with a compatible UPS uninterruptible power supply upstream to complete a protected, remotely-managed power chain. For rack builds requiring structured cable management alongside high-density power, review the rack accessories category for blanking panels and cable managers that complement 0U vertical PDU installations. If you are designing a complete rack power strategy, the power distribution planning guide covers load calculations, phase balancing, and PDU selection criteria for mixed-voltage environments.

Frequently Asked Questions

Q: What input plug does the APDU10250SW use?

A: The APDU10250SW uses a 520P6 input plug — a 3-phase, 20A connector. Confirm your facility's power whip termination matches before ordering. This is not compatible with standard single-phase NEMA or IEC C20 feeds.

Q: Can outlets be controlled individually on the APDU10250SW?

A: Yes. As a switched PDU, each of the 42 outlets supports independent remote on/off/reboot control, which is the primary differentiator versus metered or basic PDU variants in the NetShelter line.

Q: Does the APDU10250SW work at both 50 Hz and 60 Hz?

A: Yes. The unit accepts both 50 Hz and 60 Hz input, making it deployable across facilities in North America, Europe, and other regions without frequency-specific variants.

Q: How long is the power cord on the APDU10250SW?

A: The input cord is 1.8 meters (5.9 feet), providing enough reach for standard top-of-rack or bottom-feed routing within a full-height cabinet.

Q: What is the physical length of the APDU10250SW and how does it mount?

A: The unit is 149.0 cm (58.66 in) long and installs vertically in the rear 0U channel of an EIA-310 standard cabinet. It does not consume front rack units.

Q: What does the APDU10250SW weigh, and are there installation requirements?

A: It weighs 7.2 kg (15.9 lb). Given the length and weight, a two-person install or use of a lift is recommended, and mounting before rack population simplifies positioning.

Marty Allison
Marty Allison

The APDU10250SW is the unit I reach for when a customer is running a 3-phase international facility and needs 42 independently-controlled outlets in a single rear-channel vertical mount — specifically because the 520P6 input and 415V/20A rating line up with standard European data center panel feeds without adaptation. If you are speccing this for a North American 208V environment, stop and confirm your panel voltage before quoting — the 415V input rating is not universal.

Technical Highlights:

  • 11.5KW 3-Phase Capacity: At 11.5KW distributed across three phases, this PDU can carry a fully-loaded high-density rack without pushing any single phase past safe utilization thresholds — load balancing is built into the 3-phase architecture, not an afterthought.
  • 42 Switched Outlets: Per-outlet switching at 42 positions means you can reboot a single hung edge server or NVR at 2 AM without dispatching a technician — direct operational cost savings in multi-site security and compute deployments.
  • Dual-Frequency 50/60 Hz Input: A single SKU that ships to Geneva or Chicago without a frequency-specific variant order — useful for global enterprise procurement teams standardizing rack infrastructure across regions.

Deployment Considerations:

  • Confirm the facility power whip is terminated with a 520P6 connector before the unit ships — field adapter solutions for 3-phase plugs are not trivial, and a mismatch delays commissioning by days, not hours.
  • At 149 cm and 7.2 kg, schedule a two-person install window and mount the PDU on the vertical rails before any servers go in — trying to slide a full-length PDU past populated rack equipment is a common field mistake that damages both the PDU and adjacent gear.

The APDU10250SW is purpose-built for international enterprise data centers and converged security infrastructure rooms running 3-phase 415V panel feeds — if your facility matches that profile, this is the correct unit. If your rack room runs single-phase or North American 208V 3-phase, a different NetShelter variant is the right call.

Specifications
Color: Black
Product Or Component Type: PDU
Pdu Type: Switched
Cord Length: 5.9 ft (1.8 m)
Dimensions: 58.66 in (149.0 cm)
Output Voltage: 240 V
Weight: 15.9 lb (US) (7.2 kg)
Input Frequency: 50/60 Hz
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources