APC by Schneider Electric
SKU: APDU11250SM
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU10250SM is a 0U vertical rackmount power distribution unit designed for high-density, three-phase data center and enterprise rack environments running on 415V infrastructure. Delivering 11.5KW of managed three-phase power through 48 individually switched and metered AC outlets, this PDU gives operations teams the granular visibility and remote control they need to eliminate truck rolls for simple outlet-level power cycling and to catch over-loaded circuits before they take down a rack. If you're managing a colocation cage, a dense virtualization row, or a critical comms rack where power events are expensive, this is the class of device that belongs in the deployment.
The APDU10250SM ships in black and mounts vertically in a 0U footprint — it lives in the side channel of the rack rather than consuming rack units, preserving every U for compute. The integrated LCD display gives local operators instant current, voltage, and load readings without pulling up a browser session, which matters during an incident when every second counts.
The APDU10250SM integrates into APC by Schneider Electric's EcoStruxure IT management ecosystem, supporting centralized monitoring through APC's network management infrastructure. The dual Ethernet ports and daisy chain architecture are designed for rack PDU deployments in environments already running APC network management cards or compatible DCIM platforms. For facilities building out a complete power management strategy, pair this unit with upstream UPS systems sized to the 11.5KW load. If your data center power management framework requires per-outlet energy reporting for chargeback or capacity planning, the per-outlet metering here feeds that workflow directly without additional current transducers or submetering hardware. Consult your data center infrastructure documentation for phase load balancing requirements before commissioning — 415V three-phase installations require qualified electrical work and proper phase assignment planning.
Q: What input plug type does the APDU10250SM use?
A: The APDU10250SM uses an IEC 60309 input plug, the international industrial-grade connector standard widely specified in purpose-built data centers and colocation facilities operating on 415V three-phase infrastructure.
Q: How many outlets does the APDU10250SM provide, and what types?
A: The unit provides 48 AC outlets across four coupler types: C13, C15, C19, and C21. The mix supports everything from standard 1U servers (C13/C15) to high-draw blade chassis and storage controllers (C19/C21).
Q: Can multiple APDU10250SM units be managed under a single IP address?
A: Yes. The APDU10250SM supports daisy chaining via its dual RJ-45 Ethernet ports, allowing multiple units to be linked and managed centrally without requiring a dedicated switch port per PDU.
Q: Does the APDU10250SM allow remote power cycling of individual outlets?
A: Yes. As a switched, metered-by-outlet PDU, each of the 48 outlets can be individually switched on, off, or power-cycled remotely through the network management interface.
Q: What rack space does the APDU10250SM consume?
A: The APDU10250SM is a 0U device designed for vertical mounting in the side channel of a standard rack, so it consumes no rack unit space.
Q: What regulatory certifications does the APDU10250SM hold?
A: The APDU10250SM carries CE, CSA C22.2 No 62368-1, EN 62368-1, FCC Part 15 Subpart B, UKCA, and UL 62368-1 certifications, covering North American, European, and UK compliance requirements.

The APDU10250SM is the unit I specify when a customer needs per-outlet switched control and individual outlet metering at 11.5KW three-phase — specifically in 415V colocation and enterprise data hall environments where per-tenant or per-application chargeback reporting is a hard requirement. The 48-outlet count at this wattage class is the key reason this lands on the shortlist: you're not sacrificing outlet density to get metering granularity.
Technical Highlights:
Deployment Considerations:
The APDU10250SM is the right specification for European and APAC colocation deployments, purpose-built data halls, or enterprise data centers running 415V three-phase infrastructure where per-outlet remote switching and energy metering are non-negotiable requirements for operations and finance teams.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price