Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric APDU11250ME is a three-phase, metered rack power distribution unit rated at 11.5kW and 415V, designed for high-density data center racks and network equipment rooms where you need real-time power visibility without deploying a full switched or outlet-monitored PDU. With a 20A maximum current draw and 40 mixed-format AC outlets across four outlet types, this unit handles the power distribution requirements of dense compute, storage, and networking stacks in a zero-U form factor — saving every rack unit for revenue-generating equipment.
The APDU11250ME lands squarely in the rack PDU category for facilities engineers who need three-phase load balancing in European and international 415V environments, managed through the NMC3 network management platform via five onboard RJ-45 Ethernet ports. It is RoHS-compliant and carries UKCA, CE, and EN 62368-1 certifications — making it a straightforward fit for UK and EU deployments subject to those regulatory requirements.
The NMC3 management card is compatible with APC's EcoStruxure IT and Data Center Expert platforms for centralized power monitoring across multiple racks and facilities. The APDU11250ME integrates into existing power management software environments that support SNMP, Modbus TCP, or REST API — check your DCIM or EPMS software's NMC3 compatibility list before deployment. The 520P6 input plug type must match your facility's whip or in-row PDU output receptacle; confirm connector compatibility at the panel or upstream distribution point before installation.
Q: What input plug does the APDU11250ME use?
A: The APDU11250ME uses a 520P6 input connector, which is a standard IEC three-phase plug used in European and international 415V/400V three-phase distribution. Verify that your facility's power whip or in-row distribution unit has a matching receptacle before installation.
Q: How many outlets does the APDU11250ME have, and what types?
A: The unit provides 40 AC outlets across four IEC connector types: C13 (standard server/networking loads), C15 (higher-temperature-rated loads), C19, and C21 (high-current equipment up to 16A per outlet). The product name references 42 outlets — verify the exact outlet count and mix against the manufacturer's current datasheet for your specific revision.
Q: Is the APDU11250ME compatible with North American 208V three-phase systems?
A: No. The APDU11250ME is rated for 400V/415V three-phase input. It is not suitable for North American 208V three-phase environments. APC offers separate NetShelter PDU models rated for 208V input — select the appropriate model based on your site's distribution voltage.
Q: What management capabilities does the NMC3 platform provide?
A: The NMC3 (Network Management Card 3) provides network-based monitoring of input current, power load, and environmental thresholds. It supports SNMP, Modbus TCP, and REST API protocols and integrates with APC EcoStruxure IT and Data Center Expert platforms for centralized DCIM visibility. This is a metered PDU — it provides input-level measurements, not per-outlet switching or per-outlet metering.
Q: What certifications does the APDU11250ME carry?
A: The APDU11250ME carries UKCA (UK market), CE (EU market), EN 62368-1 (audio/video and IT equipment safety standard), and RoHS (hazardous substances restriction) certifications. These make it compliant for deployment in EU and UK data center environments subject to these regulatory requirements.
Q: Does the APDU11250ME take up rack unit space?
A: No. The APDU11250ME is a 0U device designed to mount vertically in the rack's side channel, preserving all horizontal rack unit space for computing equipment. Its 56mm width fits standard vertical PDU mounting positions in most server rack cabinets.

The APDU11250ME is the unit I'd specify for a European colocation build-out where you're running 415V three-phase distribution and need rack-level power visibility without paying for switched or outlet-metered overhead you won't use. The 11.5kW / 20A three-phase rating gives you meaningful headroom in a dense rack — and the five RJ-45 ports on the NMC3 card make daisy-chained management across a multi-PDU cabinet genuinely practical rather than a workaround.
Technical Highlights:
Deployment Considerations:
The APDU11250ME is the right fit for UK and EU data center racks running 415V three-phase where the facility team wants NMC3 integration into an existing EcoStruxure or SNMP monitoring stack, and outlet-level control is not a requirement. It's a clean, no-overhead metered PDU for environments that already have robust upstream power monitoring and just need reliable in-rack distribution with basic visibility.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price