Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric AP4432A is a 2U rackmount power distribution unit built for high-density server and network enclosures where reliable, metered AC distribution at 180–220V is the baseline requirement. Rated at 30A input with 18 total AC outlets — 16x IEC 60320 C13 and 2x IEC 60320 C19 — the AP4432A is sized for racks carrying a mix of 1U servers, network switches, and other IEC-connected equipment without forcing you to compromise on outlet count. If you're building out a datacenter row, a telecom equipment room, or a surveillance head-end rack, this unit is worth a close look within the APC by Schneider Electric power distribution lineup.
The AP4432A fits standard 19-inch EIA/ECA-310 rack enclosures and operates on 50–60 Hz AC supply, covering both 50Hz international grids and 60Hz North American feeds at the supported voltage range. Its IEC 60320 outlet standard ensures compatibility with virtually any rack-mount server, switch, NVR, or storage appliance shipping with a standard IEC power cord. For deployments requiring per-outlet switching, outlet-level metering, or remote monitoring via SNMP, consider a managed PDU variant within the rackmount PDU category — the AP4432A is a basic distribution unit and does not include network management or metering functions. Pair it with an upstream UPS for runtime protection if your application cannot tolerate unplanned power interruptions; the AP4432A distributes conditioned power from a UPS but does not provide battery backup or surge suppression on its own. For rack and enclosure selection, confirm your rack's horizontal cable management depth accommodates a 2U PDU with IEC cords routed cleanly toward equipment.
Q: What input voltage range does the AP4432A support?
A: The AP4432A operates on 180–220V AC input at 50–60 Hz, making it suitable for international single-phase feeds and 208V US datacenter environments.
Q: How many outlets does the AP4432A provide, and what types?
A: It provides 18 total outlets: 16x IEC 60320 C13 (standard server/switch connections) and 2x IEC 60320 C19 (for higher-draw equipment). Output voltage runs 200–208V.
Q: Does the AP4432A include network management or outlet metering?
A: No. The AP4432A is a basic (non-managed) rackmount PDU. It provides LED power indicators but no SNMP management, per-outlet switching, or remote monitoring capabilities. If those features are required, evaluate a managed PDU variant in the APC lineup.
Q: What certifications does the AP4432A carry?
A: The AP4432A holds REACH, RoHS, WEEE, PSE, TÜV-C, and TÜV-NURTL certifications, covering environmental compliance (EU), safety verification for North American and international markets, and Japanese PSE requirements.
Q: What is the rack space requirement for the AP4432A?
A: The AP4432A occupies 2U of standard 19-inch rack space in a horizontal rackmount orientation.
Q: What is the operating temperature range for the AP4432A?
A: Operating temperature range is -5°C to 45°C. Storage temperature range extends from -25°C to 65°C.

The AP4432A lands in a specific sweet spot: you need 18 IEC outlets across 2U, your facility runs 180–220V single-phase (208V US or European), and you don't need per-outlet switching or SNMP metering to complicate a straightforward distribution job. At 30A input with a C13/C19 outlet mix, this unit is sized for racks running moderate-density server or NVR-heavy surveillance head-end builds where the upstream UPS is handling the protection layer.
Technical Highlights:
Deployment Considerations:
For a surveillance head-end rack running 8–12 NVR appliances plus a managed PoE switch stack on a 208V feed, the AP4432A handles the distribution layer cleanly without the overhead of a managed PDU you won't actually use. It's a straightforward fit for facilities where the UPS upstream is already handling protection and monitoring.