Door Hardware & I/O
Sub categories
Showing Results for Door Hardware & I/O
-
HES
SKU: DK-CPSS
HES DK-CPSS Digital Keypad CoverPlate
Protective coverplate for HES digital keypad access control systems
- Wiegand communication ensures drop-in compatibility with existing access control panels.
- Operates on 24VDC input, aligning with standard electric strike power infrastructure.
- Supports up to 92-door deployments, scaling to mid-to-large commercial installations.
$48.00 $47.99 Save $0.01 -
HES
SKU: DL-1
HES DL-1 Door Loop 18 inch .250 ID
18" door loop with .250" ID for HES electromechanical access systems
- 18-inch length fits standard hollow metal and wood frames with no extension splicing.
- .250" ID precision-matched to HES 5000/7000 series hardware, eliminating mechanical slop.
- Plastic end caps resist corrosion and block water intrusion at frame termination points.
$31.00 $17.99 Save $13.01 -
HES
SKU: DL-2
HES DL-2 Door Loop 18 Long .375 ID Metal End Caps
18" door loop with .375" ID metal end caps for HES strike systems
- 18-inch length fits standard commercial door frames without custom fabrication.
- .375-inch ID provides universal pin compatibility with HES electric strike systems.
- Metal end caps resist deformation through repeated actuations in high-traffic installations.
$40.00 $22.99 Save $17.01 -
HES
SKU: DL-2ELECTRO
HES DL-2ELECTRO Armored Door Loop 18in
18" armored door loop for HES Electrolynx access control systems
- 18-inch armored metal construction withstands mechanical stress at high-traffic entryways.
- Metal end caps resist corrosion, maintaining structural integrity in demanding environments.
- Electrolynx-compatible design enables direct integration with HES electronic strike systems.
$91.00 $90.99 Save $0.01 -
HES
SKU: DL-30
HES DL-30 Armored Cable 30 Feet
30-foot armored cable for HES DL-2 locks in high-risk areas
- Armored construction resists cutting and abrasion in vandalism-prone zones
- 30-foot length spans extended runs between controller and electrified lock
- Rated for indoor and outdoor deployment in high-traffic installations
$97.00 $96.99 Save $0.01 -
HES
SKU: DL-36
HES DL-36 Electric Strike with Armored Cable
36" armored cable electric strike for 12/24VDC access control
- Integrated DL-2 strike with armored sheathing resists cutting and vandalism
- Works indoors and outdoors; compatible with standard 12VDC and 24VDC systems
- 36-inch cable spans typical frame-to-panel distances in commercial installations
$109.00 $108.99 Save $0.01 -
HES
SKU: DL-48
HES DL-48 48ft Armored Cable Assembly
48ft armored cable assembly for DL-2 security systems
- 48-foot length with armored construction resists vandalism and abrasion
- DL-2 compatible connectors integrate directly into existing installations
- Maintains signal integrity across indoor and outdoor deployments
$127.00 $126.99 Save $0.01 -
HES
SKU: DL-60
HES DL-60 60ft Armored Cable Assembly
60ft armored cable for HES DL-2 strikes in tough outdoor environments
- 60-foot length supports extended cable runs with cut-resistant armoring
- Armored construction protects against tampering, rodent damage, and UV
- Rated for interior and exterior deployments in high-security installations
$140.00 $139.99 Save $0.01 -
HES
SKU: DL2EC
HES DL2EC DL-2 End Caps Set of 2
Protective end caps for HES DL-2 series devices, indoor/outdoor
- Set of 2 OEM-spec caps seals both DL-2 endpoints in a single replacement kit.
- Outdoor-rated construction blocks moisture and dust from internal connectors.
- Drop-in fit eliminates modification across rack, wall-mount, and cabinet installs.
$24.00 $13.99 Save $10.01 -
HES
SKU: DPS-C-38G
HES DPS-C-38G A100 Door Position Switch
Real-time door status monitoring for HES access control systems
- 24VDC input aligns with standard access control power infrastructure, no added PSU.
- Wiegand protocol enables drop-in integration with HES A100 and third-party platforms.
- Two mounting orientations support both new construction and retrofit door installations.
$50.00 $24.99 Save $25.01 -
HES
SKU: DPS-M-BK
HES DPS-M-BK Door Position Switch for Metal Doors
Magnetic door position switch for metal doors with dry contact output
- Reed switch design eliminates mechanical wear, reducing maintenance in high-traffic door installations.
- Dry contact output integrates voltage-free into any access control panel or alarm receiver.
- Compact 1.6 x 1 x 0.1 in profile with black finish for discreet mounting on metal door frames.
$43.00 $23.99 Save $19.01 -
HES
SKU: DPS-M-GY
HES DPS-M-GY Door Position Switch Metal
Metal door position switch for HES/ASSA ABLOY access control
- Engineered for metal frames—eliminates EMI false signals on steel and aluminum doors.
- Integrates natively with HES, ASSA ABLOY, and Securitron—no custom drivers needed.
- Compact 2.4 × 2.4 × 2.4 in form factor simplifies installation in tight door frames.
$43.00 $23.99 Save $19.01 -
HES
SKU: DPS-M-WH
HES DPS-M-WH Door Position Switch for Metal Doors
Dry contact door position switch for metal doors and access control
- Dry contact output integrates with any third-party access control panel or alarm receiver.
- Purpose-built for metal door frames, reducing false reads common with generic switches.
- Real-time open/closed status feedback supports accurate alarm response and audit logging.
$43.00 $23.99 Save $19.01 -
HES
SKU: DPS-W-BK
HES DPS-W-BK Door Position Switch for Wood Doors
Surface-mount door position switch for wood frames, no drilling
- Door position switch engineered for wood doors (black)
- Surface-mount install - no drilling or routing required
- Cuts install labor on wood door retrofit projects
$33.00 $17.99 Save $15.01 -
HES
SKU: DPS-W-GY
HES DPS-W-GY Door Position Switch for Wood Doors
Real-time door position switch for wood doors, surface or frame mount
- Door position switch engineered for wood doors (gray)
- Wood-substrate bracket reduces false triggers vs generic
- Surface or frame mount for standard commercial doors
$33.00 $17.99 Save $15.01 -
HES
SKU: DPS-W-WH
HES DPS-W-WH Door Position Switch for Wood Doors
Wood door position switch with dry contact output for access control
- Engineered for wood door frames, eliminating retrofit fitment issues at installation.
- Delivers dry-contact open/closed binary feedback directly to access control panels.
- Lightweight at 0.05 lb, minimizing door hardware load on standard wood frame assemblies.
$33.00 $17.99 Save $15.01
Door Hardware & I/O
Door hardware and I/O components connect physical doors to your access control system. From electric strikes and magnetic locks to exit devices and relay modules, proper hardware selection ensures safe, compliant, and reliable operation.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type (wood, metal, glass, storefront)
- Request-to-exit (REX) device requirements
- Power supply and voltage compatibility
- Local life-safety and fire code compliance
Door Hardware & I/O — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 532 working models of door hardware & i/o sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| Resolution | 8MP, 2MP |
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, Battery |
| Type | Accessory, Controller, Cable, Switch, Power Supply, Access Card, Contact, Lock/Strike |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.




