Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The HES DPS-M-WH is a purpose-built door position switch engineered specifically for metal door installations in access control and security systems. This switch provides real-time monitoring of door open/closed status through reliable dry contact switching, enabling integration with access control panels, alarm systems, and building automation platforms. The DPS-M-WH (often searched as DPS M WH) is the correct choice when you need proven position feedback on metal entry points without the complexity of electronic latching mechanisms.
The DPS-M-WH wires directly to any access control panel or alarm receiver that accepts dry contact inputs. Standard terminal block or screw-down connections — no specialized connectors. Supports both failsafe (door-locked-on-power-loss) and failsecure (door-unlock-on-power-loss) logic depending on your site's security policy. Compatible with Honeywell, Tyco, and most third-party access control panels via dry contact wiring. Works with building automation systems (BACnet, KNX) through relay modules if direct contact integration is not available on your BMS. Access control integration planning resources outline typical wiring schematics.
Deploy the DPS-M-WH at any metal entry point requiring position monitoring: server room doors, secure document storage, data center ingress points, pharmacy vaults, and controlled-access zones in government and healthcare facilities. Install the switch on the door frame or strike assembly — exact mounting depends on your strike type and frame geometry. Typical installation requires only a drill, terminal block, and a run of 18–22 AWG pair cable to the control panel. Verify door swing direction and strike alignment before installation; misalignment will cause missed or false readings and complicate troubleshooting later.
Contact the manufacturer or your specialty distributor for exact package contents, as documented specifications were not available at the time of publication.
Q: Can the DPS-M-WH be used on wood or composite doors?
A: The switch is designed and tested for metal door frames and strike assemblies. Wood and composite doors may not provide the same magnetic or mechanical engagement. Verify with the manufacturer or test in a pilot installation before ordering for non-metal applications.
Q: What is the dry contact rating (voltage and current)?
A: Dry contact switches typically handle low-voltage signals (under 50V) and low-current loads (under 2A). Your access control panel documentation will specify the required contact type. If you are switching high-voltage or high-current circuits, use a relay module between the DPS-M-WH output and the load.
Q: Is the DPS-M-WH suitable for outdoor doors?
A: No. The switch is rated for indoor commercial and institutional environments. Outdoor or high-moisture applications require an industrial-rated switch with IP67 or higher sealing. Confirm your installation location is indoors and climate-controlled before ordering.
Q: How do I wire the DPS-M-WH to my access control panel?
A: Run a two-conductor pair (18–22 AWG) from the switch terminals to the dry contact input on your control panel. Typically no polarity requirement for dry contact circuits. Consult your panel's installation manual for the correct input port and configuration. Your integrator can provide a wiring diagram specific to your panel model.
Q: What is the warranty on the HES DPS-M-WH?
A: Warranty details were not available in the current evidence. Contact the manufacturer or your specialty distributor for warranty period and terms.
Q: Will the DPS-M-WH work with my existing access control system?
A: If your system accepts dry contact inputs, yes. Most modern access control panels (Honeywell, Tyco, Salto, etc.) support dry contact door sensors. Verify your panel's technical documentation or consult your system integrator to confirm input availability and configuration.
The HES DPS-M-WH is a straightforward, no-nonsense door position switch that does one job well: dry contact feedback from metal door frames. It's the kind of device that disappears into your infrastructure — no alerts, no fuss, just reliable state change signaling to your access control panel or alarm receiver. In a typical deployment, you wire it once during installation and never think about it again unless there's a hardware failure. The dry contact output is its strength; it plays nice with virtually any control system without requiring custom drivers or middleware.
Technical Highlights:
Deployment Considerations:
The DPS-M-WH is the right fit for server rooms, secure storage vaults, pharmacy doors, and controlled-access facilities in office, healthcare, and government buildings. If you are deploying dozens of doors across a campus, its simplicity and compatibility pay off in reduced commissioning time and fewer integration headaches. For outdoor or high-vibration applications, specify an industrial-grade position sensor instead.