Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv ADX-1YSLV-MP1000 Digital Workspace Media Player Appliance

Overview

The Vertiv ADX-1YSLV-MP1000 is a compact digital infrastructure appliance designed for deployment at the endpoint side of Vertiv's ADX KVM-over-IP and virtual desktop delivery architecture. Purpose-built to serve as the client node in centralized computing environments, it puts the processing and display capability where the user sits — without requiring a full-size workstation at every desk. If you're extending virtual desktop access to operator stations, control rooms, or secure network zones, this is the appliance that bridges the gap between your hosted infrastructure and the physical workspace.

The ADX-1YSLV-MP1000 ships in a 2U-class compact chassis (3.5 in height dimension) with a redundant dual 350W power supply configuration — an often-overlooked detail that matters in 24/7 operations where a single PSU failure shouldn't take a workstation offline. It belongs squarely in the category of digital infrastructure endpoint appliances, and its port complement reflects serious integration intent: dual 1G network ports, two USB 3.0 ports, a VGA display connector, and a DB9 serial management port.

Key Features

  • Dual 350W Redundant Power Supplies: Each PSU operates at 350W, and the redundant pair means a supply failure doesn't interrupt operations. For control rooms and NOC environments running 24/7 shifts, this eliminates the single point of failure that trips up less hardened endpoint appliances.
  • 2x 1G Network Interfaces: Two independent Gigabit Ethernet ports give you flexibility to separate management traffic from the primary data path, bond for throughput, or connect to isolated network segments — a practical advantage in segmented IT/OT environments where network zoning is enforced.
  • 2x USB 3.0 Ports: USB 3.0 delivers up to 5 Gbps per port, which means high-speed peripheral handoff — smart card readers, CAC authentication tokens, high-resolution cameras, and storage devices — all operate without the bottleneck that plagues USB 2.0-equipped thin clients on the same tasks.
  • 1x DB9 Serial Management Port: The RS-232 serial port gives you out-of-band console access to the appliance itself. In environments where the network is down or you're troubleshooting a misconfigured unit, this is how you get in without a crash cart — a real advantage over appliances that rely entirely on IP management.
  • VGA Display Output: VGA provides broad compatibility with existing monitor infrastructure. In brownfield deployments where display budgets are constrained or existing VGA monitors are already in place, this avoids a forced display refresh cycle just to deploy the appliance.
  • 3-Fan Cooling: A 3-fan active cooling array handles thermal management across the dual power supplies and compute components. For continuous-duty deployments where ambient temperatures may approach the 35°C upper operating limit, active cooling maintains component longevity without thermal throttling.
  • Dedicated Management Port: A separate 1x management interface isolates administrative access from production traffic. This means firmware updates, configuration changes, and monitoring happen on a dedicated path — reducing risk of management traffic saturating a production NIC during high-load sessions.
  • 10–35°C Operating Range: The 50–95°F operating band is standard data center and office range, meaning no special HVAC engineering is required for typical deployments. The -40 to -65°C storage temperature rating means units can be warehoused or shipped through cold climates without damage to components.

Integration & Compatibility

The ADX-1YSLV-MP1000 is built for the Vertiv Avocent ADX ecosystem, pairing with ADX switching, management, and virtual desktop infrastructure components. The dual 1G network ports support integration into VLAN-segmented environments common in enterprise IT and operational technology deployments. The DB9 serial port accommodates integration with serial console servers for centralized out-of-band management. For organizations running network management platforms, the dedicated management interface provides a clean separation between production and administrative planes.

The USB 3.0 ports support peripheral redirection for use cases requiring local smart card readers, biometric devices, or USB-attached storage — common requirements in secure government, finance, and critical infrastructure environments. Note that VGA is the sole display interface documented in available specifications; buyers requiring DisplayPort or HDMI connectivity should verify display compatibility before deployment or consider alternative ADX endpoint models.

Frequently Asked Questions

Q: Does the ADX-1YSLV-MP1000 support redundant power supply operation?

A: Yes. The ADX-1YSLV-MP1000 ships with dual 350W power supplies configured for redundancy. A single PSU failure will not interrupt appliance operation, making it suitable for 24/7 environments where uptime is critical.

Q: What display interfaces does the ADX-1YSLV-MP1000 support?

A: Based on available specifications, the ADX-1YSLV-MP1000 includes a VGA display output. If your deployment requires DisplayPort or HDMI, verify compatibility with Vertiv before ordering.

Q: How many network ports does the ADX-1YSLV-MP1000 have?

A: The appliance includes two 1G network interfaces plus a dedicated management port, giving you three separate network connection points total. This supports traffic separation between production and management networks.

Q: What are the operating temperature limits for the ADX-1YSLV-MP1000?

A: Operating temperature is rated 10–35°C (50–95°F) with humidity tolerance of 10–80% RH (max dew point 29°C). Storage temperature extends to -40°C, so cold-climate warehousing and shipping are not a concern.

Q: What type of serial port does the ADX-1YSLV-MP1000 include?

A: The appliance includes one DB9 RS-232 serial port for out-of-band console management, allowing direct access to the unit independent of network availability.

Q: What USB specification does the ADX-1YSLV-MP1000 use?

A: The ADX-1YSLV-MP1000 includes two USB 3.0 ports, supporting up to 5 Gbps per port — suitable for CAC readers, smart cards, high-speed storage, and other peripherals requiring fast USB throughput.

Jerry Tildsen
Jerry Tildsen

The spec that stands out to me on the ADX-1YSLV-MP1000 is the dual 350W redundant power supply configuration — that's not a feature you see on every endpoint appliance, and it's exactly what separates a serious 24/7 deployment from a device that creates a new single point of failure at the operator station. If you're commissioning this for a NOC, control room, or secure operations environment, that PSU redundancy is load-bearing for your uptime SLA.

Technical Highlights:

  • Dual 350W Redundant PSU: 700W total capacity across two supplies means one can carry full load if the other fails — zero-downtime PSU swap in environments that run continuous shifts.
  • 2x USB 3.0 + DB9 Serial: USB 3.0 at 5 Gbps per port handles CAC readers and biometric peripherals without throughput compromise; the DB9 gives you a console lifeline when IP management is unavailable.
  • Dual 1G NICs + Dedicated Management Port: Three discrete network attachment points let you enforce traffic segmentation without a managed switch doing the heavy lifting — the appliance handles it natively.

Deployment Considerations:

  • The 3.5 in chassis height and 10–35°C operating range mean this unit fits standard rack or desktop deployments without special environmental conditioning, but confirm your ambient doesn't exceed 35°C at the equipment level — not the room thermostat.
  • VGA is the only documented display output. If the target operator stations have already migrated to DisplayPort or HDMI-only monitors, you'll need active adapters or need to re-evaluate the display interface before committing to a large deployment.

The ADX-1YSLV-MP1000 is the right call for centralized compute environments — government ops centers, financial trading floors, industrial control rooms — where peripheral redirection, out-of-band management, and PSU redundancy at the endpoint are non-negotiable requirements, not nice-to-haves.

Specifications
Type: Digital Infrastructure
Ports: 2 x USB, 1 x Management
Power: 2 x 350W
Connectors: VGA
Operating Humidity: 10-80% Relative Humidity with 29° C max dew point
Power Supply(S: Dual
Network Interfaces: 2 x 1G Ports
Serial Ports: 1 x DB9
Usb Ports: 2 x USB 3.0
Operating Temperature: 10 - 35° C (50-95° F)
Fans: 3
Agency Approvals: Please reference Data Sheet for Agency Approvals
Dimensions: 3.5 in
Storage Temperature: -40 to -65° C (-40 to -149° F)
Q&A
Reviews

Vertiv ADX MP1000 - ADX-1YSLV-MP1000

$1,246.00
$854.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources