Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv ADX-2YGLD-MP1000 Digital Infrastructure Management Appliance

Overview

The Vertiv ADX-2YGLD-MP1000 is a purpose-built digital infrastructure appliance designed for environments where power continuity and management access cannot be an afterthought. With dual 350W power supplies and a dedicated management port, this unit targets data center edge deployments, server rooms, and critical facility infrastructure stacks where a failed PSU should never mean a failed system.

If you're evaluating the Vertiv infrastructure line for a high-availability rack deployment, the ADX-2YGLD-MP1000 (often searched as ADX 2YGLD MP1000) positions itself as the management and power layer in a converged infrastructure stack — not a standalone compute node.

Key Features

  • Dual 350W Redundant Power Supplies: Two independent 350W PSUs mean a single power supply failure doesn't drop the appliance. For 24/7 operational environments — colocation, NOC infrastructure, or always-on access control servers — this eliminates the single-point-of-failure that plagues single-PSU alternatives. Budget for two power feeds from separate circuits to get full benefit.
  • Dedicated Management Port: A dedicated out-of-band management interface keeps administrative access alive even when the data plane is under load or misconfigured. This is the port your team should connect to the management VLAN on day one — separating management traffic from production traffic is standard practice in any hardened deployment.
  • 2x 1 Gigabit Network Interfaces: Dual 1G ports support link aggregation or network segmentation without adding an external NIC. For managed switch environments, configure one port for production traffic and one for a dedicated monitoring or backup VLAN — the hardware is already there.
  • 2x USB 3.0 Ports: USB 3.0 connectivity supports fast local media access for firmware updates, configuration backups, or log offloads. USB 3.0's throughput ceiling is orders of magnitude above what you'd need for those tasks — practically, it means no waiting on a slow USB 2.0 transfer during a maintenance window.
  • 1x DB9 Serial Port: The RS-232 DB9 serial interface provides console access that doesn't depend on the network stack being healthy. If you've ever had to recover a misconfigured network appliance with no out-of-band path, you'll appreciate having serial as a guaranteed fallback. Keep a USB-to-DB9 adapter in your on-site kit.
  • VGA Connector: Direct local display output lets technicians connect a monitor for on-site diagnostics or initial configuration without relying on remote KVM or network connectivity. Useful during commissioning and post-incident recovery.
  • 3-Fan Active Cooling: Three internal fans maintain thermal stability across the 10–35°C operating range. In a rack environment running at the upper end of that range, three fans distribute airflow more evenly than a single large fan and offer redundancy against individual fan failures.
  • 10–80% RH Operating Envelope (max 29°C dew point): The humidity specification includes an explicit dew point ceiling — not just a relative humidity percentage. This matters in environments with rapid temperature swings (loading docks, facilities with seasonal HVAC variance) where RH alone doesn't tell the full condensation risk story.

Integration and Compatibility

The ADX-2YGLD-MP1000 integrates into existing digital infrastructure stacks via its dual 1G interfaces and dedicated management port. The DB9 serial console port ensures compatibility with traditional console servers and serial terminal aggregators — a practical consideration for sites already running Lantronix, Opengear, or similar out-of-band management platforms. VGA output is compatible with standard KVM switches for centralized local access management.

Agency approvals are documented in the manufacturer's data sheet — reference that document directly for compliance requirements specific to your jurisdiction or procurement process. Operating temperature range of 10–35°C (50–95°F) aligns with ASHRAE A1/A2 data center thermal guidelines, making this unit compatible with most enterprise server room environments without special cooling provisions.

For facilities teams planning rack layouts, note the 3.5-inch form factor — confirm rack unit height from the manufacturer's data sheet before ordering mounting accessories. Pair with appropriate power distribution hardware to fully leverage the dual PSU architecture.

Frequently Asked Questions

Q: Does the ADX-2YGLD-MP1000 support redundant power input from two separate circuits?

A: The dual 350W power supply configuration supports connection to two independent power sources. For true redundancy, connect each PSU to a separate circuit or UPS feed — the hardware supports it, but the benefit depends on how the feeds are provisioned upstream.

Q: What is the operating temperature range for the ADX-2YGLD-MP1000?

A: The unit is rated for 10–35°C (50–95°F) operating temperature, aligning with standard enterprise server room and data center environments under ASHRAE A1/A2 guidelines.

Q: What connectivity ports are included on the ADX-2YGLD-MP1000?

A: The appliance includes 2x USB 3.0 ports, 1x dedicated management port, 2x 1G network interfaces, 1x DB9 serial port, and 1x VGA output.

Q: What is the humidity tolerance for the ADX-2YGLD-MP1000?

A: Operating humidity is rated 10–80% relative humidity with a maximum dew point of 29°C. The dew point ceiling is an important spec for environments with rapid temperature transitions where condensation risk exists.

Q: Can the ADX-2YGLD-MP1000 be managed out-of-band if the network is down?

A: Yes. The dedicated management port provides out-of-band access independent of the production network interfaces. The DB9 serial port provides an additional console access path that does not rely on network connectivity.

James Everett
James Everett

The ADX-2YGLD-MP1000 is the kind of appliance that earns its place in a rack by being the thing that doesn't fail when everything else is under stress. The dual 350W PSU configuration is the headline spec here — not because 700W total is unusual, but because a live-swappable redundant PSU on an infrastructure management appliance means your maintenance window for a failed power supply doesn't have to be a downtime event.

Technical Highlights:

  • Dual 350W PSUs: True hardware redundancy at the power layer — each supply is independently capable of sustaining the appliance load, so a single PSU failure is a scheduled replacement, not an emergency.
  • Dual 1G Network + Dedicated Management Port: Three network-capable interfaces let you segment production, monitoring, and out-of-band management traffic at the hardware level — no shared interface bottleneck between data plane and management plane.
  • DB9 Serial Console: Hardware-level console access independent of TCP/IP — the access path that works when nothing else does. Critical for recovery scenarios in remote or lights-out facilities.

Deployment Considerations:

  • The 10–35°C operating range is standard for conditioned server rooms but is not suitable for unconditioned edge deployments or outdoor enclosures — verify ambient temperature before specifying in any non-climate-controlled space.
  • The 3.5-inch dimension listed is likely a height reference, but confirm the exact rack unit footprint from the manufacturer data sheet before ordering rack accessories or planning dense 1U/2U deployments.

The ADX-2YGLD-MP1000 is a strong fit for NOC infrastructure racks, colocation deployments, and enterprise server rooms where power continuity and out-of-band management access are non-negotiable requirements — and where a single failed PSU needs to be a non-event, not a crisis.

Specifications
Type: Digital Infrastructure
Ports: 2 x USB, 1 x Management
Power: 2 x 350W
Connectors: VGA
Operating Humidity: 10-80% Relative Humidity with 29° C max dew point
Power Supply(S: Dual
Network Interfaces: 2 x 1G Ports
Serial Ports: 1 x DB9
Usb Ports: 2 x USB 3.0
Operating Temperature: 10 - 35° C (50-95° F)
Fans: 3
Agency Approvals: Please reference Data Sheet for Agency Approvals
Dimensions: 3.5 in
Storage Temperature: -40 to -65° C (-40 to -149° F)
Q&A
Reviews

Vertiv ADX MP1000 - ADX-2YGLD-MP1000

$2,492.00
$1,708.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources