Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology STV-FB624HA-532P6/B Switched 2U Rack PDU

Overview

The STV-FB624HA-532P6/B is a Switched PRO2 rack power distribution unit (PDU) built in a 2U form factor with 24 HDOT (High Density Outlet Technology) outlets, configured as 18x C13 and 6x CX outlets. It carries Server Technology's POPS (Per Outlet Power Sensing) and PIPS (Per Inlet Power Sensing) monitoring along with input amp meters, making it a candidate for data center and server room racks where per-outlet control and visibility into load matter more than a basic power strip. For buyers already standardizing on Server Technology power distribution, the STV-FB624HA-532P6/B fits into that same switched PDU family.

Key Features

  • 24 HDOT Outlets (18x C13 + 6x CX): the C13/CX mix covers standard server power cords and higher-draw equipment from a single unit, so mixed-load racks don't need a second PDU just for oddball connectors.
  • 2U Form Factor: keeps the outlet count high without giving up more than two rack units of vertical space — a real consideration in racks already tight on room for switches, patch panels, and cable management.
  • Switched Outlets: individual outlets can be power-cycled remotely, which matters when a hung server or network device needs a reboot and a technician isn't standing in front of the rack.
  • POPS (Per Outlet Power Sensing): per-outlet load data lets you catch an overloaded circuit or a failing power supply before it takes down the rack, rather than finding out after a trip.
  • PIPS (Per Inlet Power Sensing): inlet-level monitoring gives a whole-unit read on total draw, useful for capacity planning across multiple PDUs feeding the same panel.
  • Input Amp Meters: a local, at-a-glance amperage readout means staff can verify load without pulling up a management interface — helpful during a quick walkthrough or initial commissioning.

Integration & Compatibility

As a switched, monitored PDU, the STV-FB624HA-532P6/B is intended for racks where power state and load data need to be visible alongside the rest of the infrastructure — commonly paired with rack mount accessories and cabinet hardware already in place. Buyers planning a multi-PDU deployment should review a power and PoE planning guide before finalizing outlet counts and circuit assignments across a row of racks. STV-FB624HA-532P6/B (often searched as STV FB624HA 532P6/B) is the exact configuration covered here — confirm the outlet mix (18x C13 + 6x CX) matches your cable inventory before ordering, since C13 and CX connectors are not interchangeable.

Frequently Asked Questions

Q: What outlet types does the STV-FB624HA-532P6/B have?

A: It has 24 HDOT outlets total: 18x C13 and 6x CX.

Q: What rack space does the STV-FB624HA-532P6/B require?

A: It is a 2U rack-mount unit.

Q: Does the STV-FB624HA-532P6/B support remote outlet switching?

A: Yes, it is a Switched PRO2 model, allowing individual outlet control.

Q: Does the STV-FB624HA-532P6/B monitor power at the outlet level?

A: Yes, it includes POPS (Per Outlet Power Sensing) and PIPS (Per Inlet Power Sensing).

Marty Allison
Marty Allison

The outlet mix on the STV-FB624HA-532P6/B is what stands out to me — 18x C13 plus 6x CX in a single 2U chassis, so you're not stuck running a second strip for equipment that needs the CX connector. That's the detail I check first on any switched PDU spec sheet.

Technical Highlights:

  • 24 HDOT Outlets (18x C13 + 6x CX): high-density layout gets you 24 controllable outlets without exceeding 2U, which matters when rack space is already spoken for.
  • POPS + PIPS Monitoring: per-outlet and per-inlet sensing means you can isolate a problem outlet instead of guessing which device on the strip is pulling excess load.
  • Input Amp Meters: a local readout lets you sanity-check total draw during install without logging into a management console first.

Deployment Considerations:

  • Verify your cable inventory against the 18xC13/6xCX split before rollout — CX-terminated equipment cords aren't interchangeable with C13 gear.
  • Full voltage, amperage, and input plug specs weren't available in the evidence reviewed for this listing — confirm those ratings against the unit's nameplate or manufacturer documentation before sizing it to your circuit.

This is a fit for a data center or server room rack that's already standardized on Server Technology's Switched PRO2 line and needs outlet-level power cycling and load visibility across a mixed C13/CX equipment set, model STV-FB624HA-532P6/B specifically for that 18+6 outlet split.

Specifications
Form Factor: 2U
Outlet Configuration: 24 HDOT Outlets (18x C13 + 6x CX)
Features: Switched, POPS, PIPS, Input Amp Meters
Brand: Server Technology
MPN: STV-FB624HA-532P6/B
Outlet Types: 18x C13 + 6x C19
Input Metering: Amperage
Q&A
Reviews

Server Technology Switched PRO2 Pops Pips - STV-FB624HA-532P6/B

$2,803.00
$2,711.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources