Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology STV-FB624HA-L2130 Switched 2U Rackmount PDU
Overview
The STV-FB624HA-L2130 is a Switched PRO2 POPS PIPS power distribution unit from Server Technology built for data center racks that need outlet-level control and 3-phase input capacity in a compact 2U footprint. With 24 total outlets — 18x IEC C13 plus 6x C13/C19 combo (CX) receptacles — this PDU is sized for dense server or network racks where mixed C13/C19 power cords are common and rack space is at a premium. The STV-FB624HA-L2130 pulls 30A at 208V through a NEMA L21-30P input plug, delivering 8.6kW of input power capacity to the rack, and includes input amp meters so staff can read draw at a glance during commissioning or load audits.
Key Features
- 24 total outlets (18x C13 + 6x CX): The 6 combo CX outlets accept either C13 or C19 cords, giving you flexibility to mix standard servers with higher-draw switches or storage arrays on the same strip without pre-planning cord types outlet by outlet.
- Switched outlet control: Individual outlets can be powered on, off, or cycled remotely — useful for rebooting a hung device without a trip to the data center floor, and for staging sequenced power-up on circuits with inrush concerns.
- 3-phase input: Spreads load across three phases instead of one, which matters when a single 2U strip is feeding 24 outlets — it keeps per-phase current balanced and avoids overloading a single leg of the panel.
- 30A NEMA L21-30P input, 4m cord: A locking twist-lock plug rated for 30A keeps the cord seated under rack vibration and cable movement, and the 4-meter length gives enough reach to route to overhead or underfloor power whips without an extension.
- 208V input, 8.6kW capacity: At 208V 3-phase, 8.6kW of headroom covers a fully loaded rack of servers and network gear — plan your actual connected load against this ceiling before populating all 24 outlets.
- Input amp meters: Local digital readout of input current lets a technician verify actual draw against the 30A/8.6kW rating during commissioning, instead of estimating from nameplate wattage alone.
- 2U rackmount form factor: Fits a standard 19-inch rack using just 2U of vertical space, leaving the rest of the rack for compute and network equipment rather than power infrastructure.
Integration & Compatibility
The STV-FB624HA-L2130 is built to mount in standard 19-inch server racks alongside the servers, switches, and storage it powers — see rack-mount power distribution units for compatible rack power gear. Because outlets are individually switched, this PDU pairs well with remote power management workflows already common in colocation and enterprise data center environments. Before ordering, confirm your facility has 208V 3-phase service terminating in a NEMA L21-30P receptacle at the rack location — this unit is not a drop-in replacement for single-phase 120V strips. For guidance on matching PDU capacity to rack load, see the PDU and power planning guide. Pair this unit with the broader Server Technology power distribution line when standardizing PDU models across multiple racks, and review rack cabinets and enclosures if you're speccing a new rack build around it. For sites managing dozens of racks, coordinating outlet-level switching across units is worth planning into your data center infrastructure guide before rollout.
Frequently Asked Questions
Q: How many outlets does the STV-FB624HA-L2130 have?
A: 24 total outlets: 18x IEC C13 and 6x combo C13/C19 (CX) receptacles.
Q: What input voltage and current does the STV-FB624HA-L2130 require?
A: It requires a 208V 3-phase circuit at 30A, connecting via a NEMA L21-30P locking plug.
Q: How much rack space does the STV-FB624HA-L2130 take up?
A: It is a 2U rackmount unit, designed to fit a standard 19-inch server rack.
Q: Can outlets on the STV-FB624HA-L2130 be controlled individually?
A: Yes, it is a switched PDU, allowing individual outlet-level power control.
Q: What is the maximum input power capacity of the STV-FB624HA-L2130?
A: 8.6kW at 208V 3-phase input.
Q: How long is the input power cord on the STV-FB624HA-L2130?
A: The input cord is 4 meters long.

The STV-FB624HA-L2130 crosses my desk whenever a customer is trying to fit high outlet density into a short rack unit budget. Twenty-four outlets across 18x C13 and 6x combo CX in 2U is a tight package, and the 3-phase 30A input is what makes that outlet count workable without tripping a breaker.
Technical Highlights:
- 8.6kW input capacity at 208V 3-phase: That headroom is what lets you actually populate all 24 outlets with mixed server and network loads rather than half-loading the strip to stay under a lower single-phase ceiling.
- 6x combo CX outlets: Each of those six accepts either a C13 or C19 cord, so a rack with a mix of 1U servers and higher-draw switches or storage shelves doesn't need a separate outlet plan for each cord type.
- Input amp metering: Reading actual input current locally, at the unit, during commissioning is how you catch a miscalculated load before it becomes a 3am page.
Deployment Considerations:
- Confirm the rack location actually has a 208V 3-phase circuit terminating in a NEMA L21-30P receptacle before ordering — this is not a unit you adapt onto single-phase 120V power.
- The 4m input cord is generous for overhead or underfloor whips, but measure your actual run first on rows with tight cable trays — twist-lock cords aren't something you want to extend with an adapter.
This is the unit I'd spec for a colocation cage or enterprise server room row where you're standardizing on 3-phase power and need outlet-level remote control across a dense mix of C13 and C19 equipment, not for a single-server closet on 120V.
Compare with similar
Server Technology Switched PRO2 Pops Pips 2U - STV-FB624HA-L2130
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology