Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology STV-FB636A-532P6/B 0U Switched Rack PDU
The Server Technology STV-FB636A-532P6/B is a 0U vertical switched power distribution unit built for three-phase data center racks that need per-outlet control across a large, mixed-connector load. With 36 total outlets — 24x IEC 60320 C13 and 12x IEC 60320 C19 arranged in alternating phase HDOT layout — this PRO2 Switched POPS unit is sized for dense server and network equipment racks where you're mixing standard servers, switches, and higher-draw devices like blade chassis or storage arrays on a single strip.
Overview
This is a Primary PRO2 Switched unit, meaning it's designed as the primary distribution strip in an A/B redundant power setup, or as a standalone switched strip where remote outlet control matters more than metering granularity alone. The STV-FB636A-532P6/B pulls 400/415V AC three-phase input through an IEC 60309 3P+N+PE connector rated for 32A input current, delivering a total power capacity of 22.9 kW per unit — enough headroom for a fully populated 42U rack running mixed 1U/2U servers plus a couple of higher-draw network appliances.
Key Features
- 36 total outlets (24x C13 + 12x C19): covers standard server power cords (C13) and higher-current devices like switches and blade enclosures (C19) from one strip — no need to run a second PDU for mixed-load racks.
- HDOT alternate phase outlet sequencing: outlets are arranged so adjacent sockets pull from different phases, which balances load across the three-phase input and reduces the chance of overloading a single phase when techs plug in equipment without checking a phase map.
- 22.9 kW total power capacity: gives you real headroom for a densely populated rack — plan your actual load against this ceiling rather than guessing, since exceeding it trips the input breaker.
- 32A input current at 400/415V 3-phase: matches standard European and international three-phase data center feeds, and the higher voltage means lower current draw per kW delivered compared to single-phase 208V setups.
- 0U vertical rackmount, 68.9" height: mounts in the rear rack channel without consuming any horizontal U space — critical when every 1U counts for compute or network gear, not power infrastructure.
- Switched (POPS) outlet control: per-outlet switching lets you remotely power-cycle a hung server or network device without a physical trip to the rack, and lets you sequence equipment power-up to avoid inrush current spikes on a shared circuit.
- 13.1 ft input cord length: reaches from a rack-mounted PDU position back to overhead or under-floor power whips without requiring an extension, simplifying cable management in a raised-floor data hall.
- 50/60 Hz frequency support: works on both North American 60Hz and international 50Hz power infrastructure, useful if this unit is standardized across a multi-region deployment.
- 230V AC output per outlet: matches the standard IEC voltage most rack-mount servers, switches, and storage controllers expect from their C13/C19 power inputs.
Integration & Compatibility
The STV-FB636A-532P6/B fits into the same PRO2 Switched POPS family used across Server Technology power distribution units, so racks already standardized on PRO2 switched or metered strips can add this unit without introducing a new management interface. As a 0U vertical unit at 2.17" wide and 2.95" deep, it mounts in the rear rack channel alongside cable management arms without competing for front-of-rack space. Pair it with a compatible rack-mount power infrastructure plan and appropriately rated network switches when building out a full rack power and connectivity map — and review a PoE and power planning guide before finalizing outlet-to-device assignments across a multi-rack deployment.
What's in the Box
Server Technology STV-FB636A-532P6/B (often searched as STV FB636A 532P6/B) ships as the 0U switched PDU unit configured with its IEC 60309 3P+N+PE input connector and 13.1 ft power cord attached.
Frequently Asked Questions
Q: How many outlets does the STV-FB636A-532P6/B have?
A: 36 total outlets: 24x IEC 60320 C13 and 12x IEC 60320 C19, arranged in an alternating phase HDOT layout for load balancing.
Q: What input power does this PDU require?
A: 400/415V AC three-phase input at 32A through an IEC 60309 3P+N+PE connector, with a total power capacity of 22.9 kW.
Q: Does the STV-FB636A-532P6/B take up rack space?
A: No — it's a 0U vertical rackmount unit at 68.9" tall, 2.17" wide, and 2.95" deep, mounting in the rear rack channel without consuming horizontal U space.
Q: What output voltage do the outlets deliver?
A: 230V AC per outlet across all 36 C13/C19 positions.
Q: Is this a switched or metered PDU?
A: This is a Switched POPS (Primary PRO2) unit, providing per-outlet remote power control.
Q: What power cord length does it ship with?
A: A 13.1 ft input cord.

The STV-FB636A-532P6/B is one of the higher-outlet-count switched strips I spec for mixed-equipment racks — 36 total outlets on one 0U unit means you're rarely running out of drops before you run out of rack space.
Technical Highlights:
- 24x C13 + 12x C19 outlet mix: covers the bulk of standard 1U/2U server power cords (C13) plus higher-draw C19 devices like blade chassis and core switches, without needing a second strip for the heavy stuff.
- 22.9 kW total capacity at 32A/400-415V 3-phase: that's real capacity for a fully loaded rack — I check actual nameplate draw against this ceiling before final outlet assignment, not just estimated load.
- HDOT alternate phase sequencing: outlets alternate phases down the strip, so a tech plugging in equipment left to right naturally balances the three-phase load instead of stacking it all on one leg.
Deployment Considerations:
- At 68.9" tall this is a full-height 0U vertical unit — measure your rear rack channel clearance before ordering, especially in racks already running cable management arms or a second PDU.
- The 32A/three-phase input means you need 400/415V 3-phase infrastructure at the rack position — this isn't a drop-in replacement for a 208V single-phase strip, so confirm your facility's power plan before specifying.
This is the right call for a data center rack standardizing on Server Technology's switched PRO2 platform and running a mixed C13/C19 load — think a colo cage with core switches, blade servers, and standard 1U compute all sharing one three-phase circuit.
Compare with similar
Server Technology Switched Pops Primary - STV-FB636A-532P6/B
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology