Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv SN-L1 Leak Detection Sensor

Overview

The Vertiv SN-L1 is a purpose-built water leak detection sensor designed for data center and critical infrastructure environments where moisture intrusion is an existential threat to uptime. The SN-L1 (often searched as SN L1) ships with a 1-foot leak detection cable and is intended to slot directly into Vertiv's environmental monitoring ecosystem — specifically Unity and RPC2 controllers — without requiring a dedicated power supply or additional wiring beyond the communications cable. If you're managing under-floor spaces, raised computing environments, or mechanical rooms adjacent to data halls, this sensor closes a monitoring gap that thermal or humidity sensing alone cannot cover.

Unlike standalone water alarms that only alert locally, the SN-L1 feeds real-time leak status into your existing Vertiv monitoring infrastructure, enabling centralized alerting and event logging alongside your other environmental data points. That integration path is what separates this from a commodity detector — the value is in the ecosystem, not the cable.

Key Features

  • Bus-powered via communications cable: The SN-L1 draws power directly through its communications cable, eliminating the need for a local power supply or outlet near the sensor. In raised-floor environments where AC power is scarce at floor level, this matters — you run one cable, not two.
  • Single leak cable input: The sensor accepts one leak detection cable, keeping the installation footprint compact. For perimeter detection or spot-checking a single at-risk zone (under a CRAC unit, near a condensate drain, adjacent to a plumbing chase), one cable is exactly what you need. Multi-zone coverage calls for multiple SN-L1 units.
  • Operating range of 41°F to 131°F (5°C to 55°C): This covers the full span of mechanical rooms and data halls — from a cold aisle running at 65°F to a hot utility space pushing into the upper range. The sensor won't false-trip or fail in either extreme within that envelope.
  • Flexible mounting via supplied bracket or cable tie: No special tools or surface prep required. The supplied bracket handles permanent wall or floor attachment; a cable tie works for temporary placement or rapid repositioning during infrastructure changes. Either approach gets the sensor in place quickly.
  • Direct integration with Unity and RPC2 platforms: Native support for Vertiv Unity and RPC2 means no driver installation, no protocol translation, and no custom scripting. The SN-L1 appears in the controller's device list and starts reporting immediately. If you're already running environmental monitoring on Unity or RPC2, this sensor adds leak coverage with minimal configuration.
  • Compact 70mm form factor: At 70mm, the sensor head is small enough to fit in tight spaces — under raised floor tiles, in cable trays, or behind equipment rows — without requiring clearance planning.

Integration & Compatibility

The SN-L1 is designed for native use with Vertiv Unity and RPC2 environmental monitoring controllers. If your monitoring architecture runs one of these platforms, the sensor integrates without custom configuration. For facilities running a broader network management or DCIM platform that polls Vertiv controllers via SNMP or Modbus, leak events from the SN-L1 will surface through whatever upstream alerting chain you've already built — the controller handles protocol translation.

This is not an ONVIF or IP-addressed device. It does not connect independently to a network switch or VMS. Its communication is through the Vertiv controller bus, so it operates only within that specific ecosystem. If your site runs a competing environmental monitoring platform, verify controller compatibility before ordering. Consult your Vertiv controller documentation to confirm the SN-L1 is listed as a supported peripheral for your specific Unity or RPC2 revision.

For facilities expanding rack-level monitoring, pairing the SN-L1 with additional power and cooling sensors on the same Unity controller builds a more complete environmental picture without adding separate monitoring infrastructure.

Frequently Asked Questions

Q: Does the SN-L1 require a separate power supply?

A: No. The SN-L1 is powered through its communications cable — no local power outlet or separate power supply is needed at the sensor location.

Q: Which Vertiv monitoring platforms does the SN-L1 integrate with natively?

A: The SN-L1 is designed for direct integration with Vertiv Unity and RPC2 environmental monitoring controllers. Compatibility with other platforms depends on whether they support the Vertiv sensor bus protocol through those controllers.

Q: How many leak detection zones can one SN-L1 sensor cover?

A: The SN-L1 has a single leak cable input, so it monitors one zone or run of leak detection cable. For multi-zone coverage, deploy multiple SN-L1 units — one per zone.

Q: What is the operating temperature range of the SN-L1?

A: The SN-L1 is rated for 41°F to 131°F (5°C to 55°C), covering standard data center, mechanical room, and utility space temperature ranges.

Q: Can the SN-L1 be mounted without tools?

A: Yes. The sensor ships with a mounting bracket for permanent installation or can be secured with a cable tie for temporary or flexible placement — no special tools required for either method.

Q: What is the physical size of the SN-L1 sensor?

A: The SN-L1 sensor measures 70mm, keeping the footprint small enough for placement in tight spaces like under raised floor tiles or within cable pathways.

Ted Perry
Ted Perry

The SN-L1 is the sensor I recommend when a site already runs Vertiv Unity or RPC2 and needs to close out the leak detection gap without adding a parallel monitoring platform. The bus-powered design is the detail that makes it practical — in raised-floor data halls where pulling an AC circuit to sensor level is a half-day job, running a single comms cable from the controller to the SN-L1 is the faster, cleaner path.

Technical Highlights:

  • Bus-powered communications cable: Eliminates local power requirements entirely — one cable run handles both data and power, which is a real installation simplification in dense floor environments.
  • 41°F–131°F operating envelope: Wide enough to span both a cold aisle set at 65°F and a utility room that climbs in summer — no environmental conditioning needed at the sensor location.
  • Native Unity and RPC2 integration: Appears in the controller device list without custom configuration, meaning leak alerts flow through the same SNMP/Modbus chain as the rest of your environmental data.

Deployment Considerations:

  • The SN-L1 has a single leak cable input — if you're monitoring a perimeter rather than a spot, plan your unit count before purchasing. One sensor, one detection run.
  • This sensor only communicates through Vertiv controller infrastructure. If your site doesn't run Unity or RPC2, the SN-L1 has no independent network connectivity and won't integrate without one of those controllers in the chain.

Best fit: a colocation or enterprise data center running Vertiv environmental monitoring on Unity or RPC2, adding spot leak coverage under CRAC units, near condensate drain lines, or at mechanical room perimeters — without expanding the monitoring platform stack.

Specifications
Type: Sensor
Mounting: Supplied bracket or cable tie
Power Supply: Through communications cable
Ports: Single leak cable input
Operating Environment: 41 to 131 degree F
Environmental Sensors: Leak Detection Sensor
Direct Integration: Unity and RPC2
Dimensions: 70 mm
Q&A
Reviews
Have Questions?

Vertiv SN Sensor - Leak Detection 1FT - SN-L1

$597.00
$409.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources