Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP6N20A1 is a 0U vertical rack PDU built for data center and server room deployments where per-outlet current visibility is non-negotiable. Rated at 20A on a three-phase 120/208V WYE input (NEMA L21-20P plug), it delivers up to 5.7kW of usable power across 24 IEC C13 locking outlets — enough to handle a full rack of 1U servers or a mixed load of network and compute gear without a separate metering unit. If you've ever had a circuit trip mid-shift because nobody was watching outlet-level draw, the VP6N20A1 is the answer to that problem.
This unit fits the power distribution tier of a well-designed rack infrastructure, slotting into a vertical 0U position so it consumes zero rack units while still providing real-time monitoring data back to your DCIM or BMS platform over dual Ethernet.
The VP6N20A1 integrates with any SNMP-based DCIM, IPAM, or NMS platform — including SolarWinds, PRTG, Nagios, and Vertiv's own Vertiv Avocent DSView and Trellis management software. Modbus TCP support extends compatibility to building management systems from Johnson Controls, Schneider EcoStruxure, and similar BMS platforms. The LDAP/RADIUS/TACACS+ stack supports Active Directory and TACACS+ servers used in enterprise and government network environments. For deployments using a structured rack cabling approach, the 0U vertical form factor pairs with standard 2-post or 4-post open-frame and enclosed racks — verify your rack rail system supports vertical PDU mounting hardware before ordering.
Q: What input plug does the VP6N20A1 use, and what panel breaker does it require?
A: The VP6N20A1 uses a NEMA L21-20P input plug, which requires a 20A three-phase 120/208V WYE circuit. Per NEC 80% continuous load rule, plan your panel breaker for a 25A three-phase circuit to stay within code for continuous loads.
Q: Does the VP6N20A1 support per-outlet switching, or is it monitoring only?
A: The VP6N20A1 is a monitored outlet-level unit — it provides per-outlet current, voltage, power, and temperature monitoring but does not offer remote outlet switching (power cycling individual outlets remotely). If you need remote outlet switching, look at Vertiv's switched PDU variants in the same family.
Q: How many PDUs can be daisy-chained together on a single IP address?
A: The VP6N20A1 supports daisy-chaining via its dual RJ-45 Ethernet ports. Consult Vertiv's configuration guide for the maximum chain length supported per firmware version — typically up to 8–16 units per chain depending on the platform, but verify against the current Vertiv documentation for your firmware revision.
Q: What network protocols does the VP6N20A1 support for enterprise integration?
A: The VP6N20A1 supports DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP v1/v2c/v3, Syslog, TACACS+, and Modbus TCP. This covers SNMP-based NMS platforms, enterprise AAA via Active Directory/LDAP, and BMS integration via Modbus TCP.
Q: What outlet type does the VP6N20A1 use, and are the outlets locking?
A: All 24 outlets are IEC C13 locking connectors (C13 coupler). The locking mechanism prevents accidental disconnection under cable tension — important in high-density racks.
Q: What is the total power capacity of the VP6N20A1?
A: The VP6N20A1 delivers up to 5.7kW at 20A on a 120/208V three-phase WYE input. Derate to 80% (4.56kW) for continuous loads per NEC guidelines.

The VP6N20A1 sits in a specific niche: you need outlet-level visibility on a three-phase 20A feed, you want the PDU to speak SNMP v3 natively, and you need it to integrate with existing AAA infrastructure without creating a fleet of locally-managed credentials. The dual RJ-45 ports for daisy-chaining are underrated — in a 10-rack row, you can manage the entire PDU fleet from two switch ports instead of ten, which matters when your OOB management VLAN switch has limited port count.
Technical Highlights:
Deployment Considerations:
The VP6N20A1 is the right unit for enterprise IT closets, colocation cage deployments, and mid-density server rooms where three-phase power is already in place, outlet-level current data feeds into a DCIM or NOC dashboard, and the management team requires SNMP v3 with centralized AAA — not a consumer-grade PDU with a web UI and local accounts.