Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP8681 Metered-by-Outlet Switched 0U Rack PDU

Overview

The APC AP8681 is an 11kW, 230V vertical zero-U rack PDU built for data center and IT closet deployments where per-outlet switching and real-time power metering are requirements, not options. Rated at 16A maximum input current on a 400V three-phase feed, it delivers 230V output across 24 outlets — a mix of 21 C13 and 3 C19 receptacles — without consuming a single rack unit of usable space. If you're managing dense compute or power distribution infrastructure where every U matters and you need outlet-level control, the AP8681 is purpose-built for that scenario.

APC's broader APC by Schneider Electric power management line spans basic rack strips through intelligent metered and switched PDUs; the AP8681 sits at the capable end of that range, combining metered-by-outlet visibility with full per-outlet switching — a combination that matters for reducing truck rolls when you need to remotely cycle a locked-up device at 2 AM.

Key Features

  • Per-Outlet Switching with Four Control Modes: Each outlet supports turn on, turn off, recycle, and lock-out commands independently. Lock-out prevents accidental power cycling on critical loads — useful in mixed-tenant or managed service environments where one team's equipment shares a cabinet with another's.
  • Metered-by-Outlet Monitoring: Current, voltage, and power are tracked at the individual outlet level, not just the PDU aggregate. That granularity lets you identify which specific device is drawing anomalously — no guesswork, no clamp meter required during a capacity audit.
  • 11,040W / 11,040VA Load Capacity at 16A: At full 16A draw on a 230V feed, you're getting genuine 11kW delivered — enough headroom for high-density blade, GPU, or storage workloads. Pair this with a rack power management strategy that keeps per-PDU utilization under 80% and you have comfortable margin before tripping the upstream breaker.
  • Zero-U Vertical Mounting: The AP8681 mounts vertically in the side channel of a standard rack, preserving all 42U (or whatever your rack height) for equipment. The 1.83m cable reach gives you enough run to dress the power cord cleanly without a tangle.
  • 24 Outlets — C13 and C19 Mix: Twenty-one C13 receptacles cover standard 1U and 2U servers; three C19 outlets handle higher-draw devices like high-end storage controllers or larger UPS loads. Having both types on a single PDU eliminates the need for adapter tails that create points of failure.
  • 400V Input, 50–60Hz Compatibility: Designed for European and international three-phase infrastructure. If your facility runs 400V distribution (common in EU data centers and purpose-built colocation), the AP8681 connects directly without step-down transformers.
  • RoHS Compliant: Meets RoHS environmental compliance requirements — relevant for enterprise procurement teams with environmental standards in supplier contracts or for deployments in the EU where RoHS compliance is a regulatory baseline.

Integration and Compatibility

The AP8681 integrates into data center infrastructure management (DCIM) platforms via APC's network management card ecosystem. The PDU's outlet-level data — current draw per port, power factor, voltage — feeds into capacity planning dashboards that help infrastructure teams prevent overloads before they become outages. The C13/C19 outlet layout is compatible with standard IEC power cords used across server, storage, and networking equipment from all major OEMs. No proprietary connectors, no adapters required for mainstream rack equipment.

Frequently Asked Questions

Q: What is the maximum load the AP8681 can handle?

A: The AP8681 supports a maximum load of 11,040W (11,040VA) at 16A on a 230V output. Input is rated at 400V with a maximum input current of 16A per phase at 50–60Hz.

Q: Can individual outlets be switched independently on the AP8681?

A: Yes. Each outlet on the AP8681 supports independent control: turn on, turn off, recycle (power cycle), and lock-out. Lock-out prevents a specific outlet from being accidentally cycled.

Q: What outlet types does the AP8681 provide?

A: The AP8681 provides 24 total outlets: 21 IEC C13 receptacles for standard server and networking equipment, and 3 IEC C19 receptacles for higher-draw devices requiring the larger connector format.

Q: Does the AP8681 take up rack unit space?

A: No. The AP8681 is a zero-U (0U) PDU that mounts vertically in the side channel of a standard rack. It does not consume any of the rack's usable 1U equipment slots.

Q: What parameters does the AP8681 monitor?

A: The AP8681 monitors current, power, and voltage — tracked at the individual outlet level (metered-by-outlet), giving granular visibility into per-device power consumption rather than just PDU-level aggregate draw.

Q: Is the AP8681 RoHS compliant?

A: Yes. The AP8681 carries RoHS compliance certification, meeting the EU Restriction of Hazardous Substances directive requirements.

Specifications
PDU types: Metered, Metered-by-outlet, Switched
Rack capacity: 0U
Mounting: Vertical
Product colour: Black
AC outlets quantity: 24 AC outlet(s)
AC outlet types: C13 coupler, C19 coupler
Cable length: 1.83 m
Monitoring: Current, Power, Voltage
Outlet control: Lock-out, Recycle, Turn off, Turn on
Nominal input voltage: 400 V
AC input frequency: 50 - 60 Hz
Maximum current: 16 A
Nominal output voltage: 230 V
Load capacity: 11040 VA
Maximum input current per phase: 16 A
Maximum total current draw per phase: 16 A
Maximum power: 11040 W
Compliance certificates: RoHS
Q&A
Reviews
Have Questions?

APC by Schneider Electric Rack PDU 2G Metered by Outlet with Switching Zerou 11.0KW 230V - AP8681

$4,670.00
$3,004.99

RELATED PRODUCTS

Save $1,464.01
APC by Schneider Electric Rack PDU 2G Metered-by-outlet Zerou 11.0KW 230V (21) C
Add to Cart The item has been added

APC by Schneider Electric AP8481

APC by Schneider Electric Rack PDU 2G Metered-by-outlet Zerou 11.0KW 230V (21) C13 & (3) - AP8481

0U vertical rack PDU delivering 11.0kW at 230V across 24 outlets — 21 IEC C13 and 3 IEC C19 — with per-outlet current, power, and voltage metering

    Usually Ships in 2-3 Weeks Free shipping over $499
    $4,180.00 $2,715.99 Save $1,464.01
    The item has been added Add to quote
    $4,180.00 $2,715.99 Save $1,464.01
    Save $1,464.01 Add to cart Add to quote
    Save $1,437.01
    APC by Schneider Electric Rack PDU 2G Metered by Outlet with Switching Zerou 32A 230V (21) - AP8653
    Add to Cart The item has been added

    APC by Schneider Electric AP8653

    APC by Schneider Electric Rack PDU 2G Metered by Outlet with Switching Zerou 32A 230V (21) - AP8653

    2G Metered-by-Outlet with Switching (MbOS) rack PDU engineered for data center operators and infrastructure teams who need granular power visibility

      Usually Ships in 2-3 Weeks Free shipping over $499
      $4,030.00 $2,592.99 Save $1,437.01
      The item has been added Add to quote
      $4,030.00 $2,592.99 Save $1,437.01
      Save $1,437.01 Add to cart Add to quote
      Save $1,394.01
      APC by Schneider Electric Rack PDU 2G Metered-by-outlet with Switching Zerou 30A - AP8632US
      Add to Cart The item has been added

      APC by Schneider Electric AP8632US

      APC by Schneider Electric Rack PDU 2G Metered-by-outlet with Switching Zerou 30A - AP8632US

      2G Metered-by-Outlet Rack PDU with Switching, designed for data center and network closet environments

        Usually Ships in 2-3 Weeks Free shipping over $499
        $3,915.00 $2,520.99 Save $1,394.01
        The item has been added Add to quote
        $3,915.00 $2,520.99 Save $1,394.01
        Save $1,394.01 Add to cart Add to quote
        Save $930.01
        APC by Schneider Electric Rack PDU 2G Metered-by-outlet Zerou 1 - AP8459WW
        Add to Cart The item has been added

        APC by Schneider Electric AP8459WW

        APC by Schneider Electric Rack PDU 2G Metered-by-outlet Zerou 1 - AP8459WW

        Rack power distribution unit from APC by Schneider Electric built specifically for high-density, space-constrained deployments where per-outlet power

          Usually Ships in 2-3 Weeks Free shipping over $499
          $2,670.00 $1,739.99 Save $930.01
          The item has been added Add to quote
          $2,670.00 $1,739.99 Save $930.01
          Save $930.01 Add to cart Add to quote
          Save $950.01
          APC by Schneider Electric Rack PDU 2G Metered-by-outlet Zerou 1 - AP8459EU3
          Add to Cart The item has been added

          APC by Schneider Electric AP8459EU3

          APC by Schneider Electric Rack PDU 2G Metered-by-outlet Zerou 1 - AP8459EU3

          Zero-rack-unit (0U), vertically mounted, metered-by-outlet rack power distribution unit delivering 24 outlets at 16A/230V via an IEC309 input

            Usually Ships in 2-3 Weeks Free shipping over $499
            $2,730.00 $1,779.99 Save $950.01
            The item has been added Add to quote
            $2,730.00 $1,779.99 Save $950.01
            Save $950.01 Add to cart Add to quote

            System Design, Deployment & Technical Support

            Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

            Fixed scope • Fixed price

            System Design Assistance

            • Get help validating product compatibility
            • Coverage requirements
            • Storage planning and deployment architecture before you buy.
            Request Design Help

            Deployment & Configuration Support

            • Access fixed-scope support for rollout planning
            • User setup guidance
            • Migration and system standardization across single-site or multi-site deployments
            View Support Services

            Guides, Tools & Calculators

            • PoE requirements
            • Storage retention
            • Camera selection and deployment methodology
            Open Technical Resources