APC Netshelter Rack PDU Advanced Switched Metered Outlet 17.3KW 3PH 415V 30 - APDU10350SM

APC by Schneider Electric APDU10350SM Advanced Switched Metered Outlet Rack PDUOverviewThe APDU10350SM is APC's three-phase vertical rack PDU built fo…

$6,825.00 $4,541.99 SAVE $2283
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter Rack PDU Advanced Switched Metered Outlet 17.3KW 3PH 415V 30 - APDU10350SM

$6,825.00
$4,541.99

Overview

SKU: APDU10350SM
UPC: 731304439745
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU10350SM Advanced Switched Metered Outlet Rack PDU

Overview

The APDU10350SM is APC's three-phase vertical rack PDU built for high-density data center and network equipment rooms where per-outlet switching and metering are non-negotiable. Rated at 17.3 kW and drawing up to 32A from a 415V IEC 60309 three-phase input, it delivers 230V nominal output across 48 outlets — covering C13, C15, C19, and C21 receptacle types in a single 0U vertical form factor. If your deployment involves mixed compute, storage, and high-draw switching loads sharing the same rack column, the APDU10350SM handles that variety without requiring separate PDU runs for different plug types.

This unit sits in APC's APC by Schneider Electric rack power lineup alongside basic metered and monitored models — but the 'Advanced Switched Metered Outlet' designation specifically means you get both real-time per-outlet current metering and the ability to remotely cycle or cut power at the individual outlet level. That combination matters operationally: you can reboot a locked server without touching the floor, and you can identify which outlets are drawing anomalous current before a breaker event occurs.

Key Features

  • 48 Outlets Across Four IEC Coupler Types: C13, C15, C19, and C21 outlets on a single unit means you are not forced into per-form-factor PDU planning. C15 covers higher-temp-rated loads (fan trays, some switches), C19/C21 handle high-amperage devices. In a mixed rack, this eliminates the need for pigtail adapters that introduce failure points.
  • 32A / 415V Three-Phase Input via IEC 60309: The IEC 60309 3P+N+E plug is the standard for European and international three-phase distribution — it mates directly with in-row or overhead busway without bespoke cabling. At 32A three-phase, this PDU can sustain a 22,100 VA load — enough headroom for a fully populated high-density rack without derating concerns in most deployments.
  • 22,100 VA Load Capacity: Translating the 22.1 kVA rating into practical terms — a rack of 1U servers drawing 500W each gives you 44 devices before you approach the ceiling. In hyperconverged or GPU-dense environments where per-node draw runs 800–1,200W, plan rack layouts accordingly and use the per-outlet metering to track actual vs. budgeted consumption in real time.
  • 0U Vertical Mounting: The zero-rack-unit vertical form factor preserves every rack unit for revenue-generating equipment. The PDU mounts in the side channel of standard 19" rack enclosures, including APC's own NetShelter SX and SV cabinets, without occupying any shelf space.
  • LCD Display: An onboard LCD gives local visibility into load status — useful during initial commissioning when you want immediate confirmation of per-phase draw without needing network access. During an outage or network isolation event, local read is the fallback.
  • No On/Off Master Switch: This PDU has no master on/off switch — outlet switching is handled per-port via the management interface, not at the PDU level. This is a deliberate design for data center environments where an accidental master shutoff would be catastrophic. Do not confuse this with a switched PDU that lacks control; individual outlet control is present, but there is no single-point kill switch.
  • -5°C to 60°C Operating Range: The 60°C ceiling covers hot-aisle/cold-aisle containment scenarios where ambient temperatures inside enclosed aisles can run significantly above standard room temperature. Down to -5°C covers warehouse distribution and edge sites that experience seasonal cold without full climate control.
  • Broad Certification Stack: CE, UKCA, FCC Part 15 Subpart B, UL 62368-1, CSA C22.2 No. 62368-1, and EN 62368-1 certifications cover North American, European Union, and UK market requirements. For multi-region enterprise rollouts, this avoids sourcing separate PDU SKUs per geography — one model qualifies across all three markets.
  • 50–60 Hz Input Frequency Compatibility: Accepts both 50 Hz (European/Asian grid standard) and 60 Hz (North American standard), which matters for international facilities or generator-backed power plants that may not hold frequency tightly under load.

Integration & Compatibility

The APDU10350SM is designed for installation in standard rack PDU environments using 19" or 600mm-wide cabinets with vertical mounting channels. The IEC 60309 inlet requires a matching facility-side whip or busway connection — confirm your power distribution infrastructure supports 3P+N+E at 32A before ordering. The four outlet coupler types (C13, C15, C19, C21) are compatible with the standard IEC 60320 appliance cords used across server, storage, and networking hardware from virtually all major equipment vendors. For deployments integrating with data center infrastructure management (DCIM) platforms, verify network management card compatibility with your DCIM vendor prior to deployment, as management card selection determines the telemetry and control protocol options available.

Frequently Asked Questions

Q: What is the difference between the APDU10350SM and a basic metered PDU?

A: The APDU10350SM is a switched metered outlet PDU — each of the 48 outlets can be individually powered on or off remotely, and each outlet is metered for real-time current draw. A basic metered PDU only reads total inlet current with no per-outlet switching capability. The 'Advanced' designation adds outlet-level control on top of outlet-level metering.

Q: How many outlets does the APDU10350SM have, and what types?

A: The APDU10350SM has 48 total AC outlets, distributed across IEC C13, C15, C19, and C21 coupler types. This mix accommodates standard server loads (C13/C19), higher-temperature-rated equipment (C15), and high-amperage devices (C21).

Q: What input plug and voltage does the APDU10350SM require?

A: The APDU10350SM uses an IEC 60309 3P+N+E input plug rated at 32A, accepting 415V three-phase input at 50–60 Hz. This is the standard international three-phase connector found in European and international data center power distribution infrastructure.

Q: What is the maximum load capacity of the APDU10350SM?

A: The APDU10350SM is rated at 22,100 VA (approximately 17.3 kW). In practice, it is advisable to plan rack loads at no more than 80% of rated capacity — roughly 17,680 VA — to maintain safe operating headroom.

Q: Does the APDU10350SM take up rack unit space?

A: No. The APDU10350SM is a 0U vertical PDU that mounts in the side channel of a rack cabinet. It consumes no rack units, leaving all available U-space for compute, storage, and networking equipment.

Q: What certifications does the APDU10350SM carry?

A: The APDU10350SM is certified to CE, UKCA, FCC Part 15 Subpart B, UL 62368-1, CSA C22.2 No. 62368-1, and EN 62368-1 — covering North American, European Union, and United Kingdom market safety and electromagnetic compatibility requirements.

Jerry Tildsen
Jerry Tildsen

When I review the APDU10350SM for a deployment, the spec I look at first is the 22,100 VA load rating against the actual rack manifest. The 32A three-phase input via IEC 60309 gives you a solid power budget, but three-phase PDU planning requires confirming that your facility's branch circuit is balanced across all three phases — if you are loading heavily on one leg and lightly on others, you are not getting the full rated capacity. This is the most common commissioning mistake I see with units like the APDU10350SM.

Technical Highlights:

  • 48 Mixed-Type Outlets (C13/C15/C19/C21): Having all four IEC 60320 coupler formats on a single vertical PDU eliminates the need for adapter chains or secondary PDU runs for high-amperage or high-temp-rated connections — each outlet type is present at the source.
  • Switched + Metered Per Outlet: The combination of individual outlet switching and per-outlet current metering is what separates this from a basic metered unit. Remote reboot capability and granular consumption data per port are the two operational capabilities that justify the cost delta over a monitored-only PDU.
  • -5°C to 60°C Operating Range: The 60°C upper limit is meaningful in hot-aisle containment environments where a poorly sealed containment system can push ambient temperatures well above 40°C inside the aisle. This unit will keep operating where a lower-rated PDU would be out of spec.

Deployment Considerations:

  • The IEC 60309 3P+N+E inlet at 32A requires a matching facility whip — this is not a NEMA-plug unit. Confirm your power infrastructure before the PDU arrives on-site; rewiring a whip mid-installation is a project delay you do not want.
  • There is no master on/off switch. Outlet control is per-port via the management interface only. If you are in an environment where a physical master cutoff is required for safety or compliance, this design will require a supplemental upstream means of isolation.

The APDU10350SM is the right call for high-density European-standard data center racks — particularly colocation environments where tenants need per-outlet billable metering and remote reboot without dispatching hands to the floor. It is not the right unit for North American NEMA-plug facilities or deployments where a physical master cutoff is a code requirement.

Specifications
PDU types: Metered, Metered-by-outlet, Switched
Type: Three-phase
Rack capacity: 0U
Mounting: Vertical
Product colour: Black
Display: LCD
On/off switch: No
AC outlets quantity: 48 AC outlet(s)
Power plug: IEC 60309
AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler
Nominal input voltage: 400 V
AC input frequency: 50 - 60 Hz
Maximum current: 32 A
Nominal output voltage: 230 V
Output voltage: 230 V
Load capacity: 22100 VA
Certification: CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Operating temperature (T-T: -5 - 60 °C
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources