APC by Schneider Electric
SKU: APDU11350SM
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU10350SM is APC's three-phase vertical rack PDU built for high-density data center and network equipment rooms where per-outlet switching and metering are non-negotiable. Rated at 17.3 kW and drawing up to 32A from a 415V IEC 60309 three-phase input, it delivers 230V nominal output across 48 outlets — covering C13, C15, C19, and C21 receptacle types in a single 0U vertical form factor. If your deployment involves mixed compute, storage, and high-draw switching loads sharing the same rack column, the APDU10350SM handles that variety without requiring separate PDU runs for different plug types.
This unit sits in APC's APC by Schneider Electric rack power lineup alongside basic metered and monitored models — but the 'Advanced Switched Metered Outlet' designation specifically means you get both real-time per-outlet current metering and the ability to remotely cycle or cut power at the individual outlet level. That combination matters operationally: you can reboot a locked server without touching the floor, and you can identify which outlets are drawing anomalous current before a breaker event occurs.
The APDU10350SM is designed for installation in standard rack PDU environments using 19" or 600mm-wide cabinets with vertical mounting channels. The IEC 60309 inlet requires a matching facility-side whip or busway connection — confirm your power distribution infrastructure supports 3P+N+E at 32A before ordering. The four outlet coupler types (C13, C15, C19, C21) are compatible with the standard IEC 60320 appliance cords used across server, storage, and networking hardware from virtually all major equipment vendors. For deployments integrating with data center infrastructure management (DCIM) platforms, verify network management card compatibility with your DCIM vendor prior to deployment, as management card selection determines the telemetry and control protocol options available.
Q: What is the difference between the APDU10350SM and a basic metered PDU?
A: The APDU10350SM is a switched metered outlet PDU — each of the 48 outlets can be individually powered on or off remotely, and each outlet is metered for real-time current draw. A basic metered PDU only reads total inlet current with no per-outlet switching capability. The 'Advanced' designation adds outlet-level control on top of outlet-level metering.
Q: How many outlets does the APDU10350SM have, and what types?
A: The APDU10350SM has 48 total AC outlets, distributed across IEC C13, C15, C19, and C21 coupler types. This mix accommodates standard server loads (C13/C19), higher-temperature-rated equipment (C15), and high-amperage devices (C21).
Q: What input plug and voltage does the APDU10350SM require?
A: The APDU10350SM uses an IEC 60309 3P+N+E input plug rated at 32A, accepting 415V three-phase input at 50–60 Hz. This is the standard international three-phase connector found in European and international data center power distribution infrastructure.
Q: What is the maximum load capacity of the APDU10350SM?
A: The APDU10350SM is rated at 22,100 VA (approximately 17.3 kW). In practice, it is advisable to plan rack loads at no more than 80% of rated capacity — roughly 17,680 VA — to maintain safe operating headroom.
Q: Does the APDU10350SM take up rack unit space?
A: No. The APDU10350SM is a 0U vertical PDU that mounts in the side channel of a rack cabinet. It consumes no rack units, leaving all available U-space for compute, storage, and networking equipment.
Q: What certifications does the APDU10350SM carry?
A: The APDU10350SM is certified to CE, UKCA, FCC Part 15 Subpart B, UL 62368-1, CSA C22.2 No. 62368-1, and EN 62368-1 — covering North American, European Union, and United Kingdom market safety and electromagnetic compatibility requirements.

When I review the APDU10350SM for a deployment, the spec I look at first is the 22,100 VA load rating against the actual rack manifest. The 32A three-phase input via IEC 60309 gives you a solid power budget, but three-phase PDU planning requires confirming that your facility's branch circuit is balanced across all three phases — if you are loading heavily on one leg and lightly on others, you are not getting the full rated capacity. This is the most common commissioning mistake I see with units like the APDU10350SM.
Technical Highlights:
Deployment Considerations:
The APDU10350SM is the right call for high-density European-standard data center racks — particularly colocation environments where tenants need per-outlet billable metering and remote reboot without dispatching hands to the floor. It is not the right unit for North American NEMA-plug facilities or deployments where a physical master cutoff is a code requirement.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →