Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric APDU10250ME is an 11.5kW, three-phase advanced metered rack power distribution unit designed for high-density data center and server room deployments running 415V infrastructure. With 42 output receptacles fed by a 20A 520P6 inlet, it delivers the outlet density and metered visibility that IT and facilities teams need when managing power loads across fully populated racks. The vertical mounting profile keeps the PDU flush in the rack column, preserving U-space for active equipment rather than consuming valuable rack real estate. For environments built on European or international 415V three-phase power — including enterprise data halls, broadcast facilities, and industrial compute rooms — the APDU10250ME is sized to match the load demands of modern high-density server and networking gear.
Explore the full APC by Schneider Electric catalog for complementary infrastructure products, or browse the broader range of rack PDUs to compare inlet configurations and outlet counts across the portfolio.
The APDU10250ME is designed for installation in APC NetShelter rack enclosures and is mechanically compatible with standard EIA-310 rack systems that include vertical PDU mounting channels. The 520P6 inlet requires a matching three-phase 415V circuit — confirm your power infrastructure matches this inlet type and voltage before deployment. For network infrastructure deployments where per-outlet switching or remote reboot capability is required, evaluate higher-tier PDUs in the APC Switched or Switched Metered families. If your environment runs 208V or 120V North American power, this unit is not the correct choice — the 415V three-phase input is specific to international and European power grids.
Pair the APDU10250ME with rack enclosures that include dedicated vertical PDU mounting brackets for a clean, tool-free installation. For environments requiring a complete data center power planning approach — including UPS sizing, PDU selection, and branch circuit design — consult the APC by Schneider Electric infrastructure guide to match PDU capacity to UPS output ratings and rack load calculations.
Q: What input plug type does the APDU10250ME use?
A: The APDU10250ME uses a 520P6 inlet connector rated for 20A at 415V three-phase. Verify your facility's power whips or floor-level distribution terminate in a compatible 520P6 receptacle before installation.
Q: How many outlets does the APDU10250ME provide?
A: The APDU10250ME provides 42 output receptacles, supporting high-density rack configurations with near 1:1 outlet-per-U availability in a standard 42U rack.
Q: What is the total power capacity of the APDU10250ME?
A: The APDU10250ME delivers 11.5kW of rack power from a 415V three-phase 20A input, suitable for fully populated high-density server and networking racks.
Q: How does the APDU10250ME mount in a rack?
A: The APDU10250ME is designed for vertical rack mounting in standard EIA-310 enclosures, including APC NetShelter racks with vertical PDU mounting channels. At 58.66 inches (149.0 cm), it spans a standard 42U rack column without consuming any U-space.
Q: Is the APDU10250ME suitable for North American 120V or 208V power infrastructure?
A: No. The APDU10250ME is configured for 415V three-phase input — the voltage standard common in European and international data centers. It is not compatible with 120V or 208V North American power circuits. Select an APC PDU with the appropriate input voltage and NEMA connector if deploying in a North American environment.
Q: What is the cord length on the APDU10250ME?
A: The APDU10250ME ships with a 5.9 ft (1.8 m) power cord, providing adequate reach from overhead busway or floor-level power taps to the rack inlet in most standard rack row configurations.

The APDU10250ME is a straightforward specification decision if your site runs 415V three-phase infrastructure and you need 42 outlets per rack column — the 11.5kW capacity at 20A is well-matched to fully populated 1U/2U server rows without requiring a higher-amperage circuit that complicates floor-level power planning.
Technical Highlights:
Deployment Considerations:
The APDU10250ME fits cleanest in a purpose-built European or international colocation cage or enterprise data hall where 415V three-phase is the site standard, rack density is high, and the operations team wants inlet-level metering without the added cost and complexity of full switched-outlet control.