Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PBRGXT5X-192VBAT PRO Refresh Plus Battery Service for Liebert GXT5 192V UPS

Overview

The Vertiv PBRGXT5X-192VBAT is a factory-new 192V battery replacement service under the PRO Refresh Plus program for the Vertiv Liebert GXT5 UPS line. This 2-year base service plan (BAS2YR) covers proactive battery replacement for GXT5 units running external 192V battery string configurations — the kind deployed in data closets, server rooms, and edge compute sites where unplanned downtime from a failed battery is simply not acceptable. If you're managing GXT5 UPS units at scale and want to get ahead of battery end-of-life before it becomes an incident, this is the plan designed for that workflow.

PBRGXT5X-192VBAT (often searched as PBRGXT5X 192VBAT) targets the 5kVA through 10kVA GXT5 models running extended-runtime 192V external battery cabinets — a common configuration in facilities that need 15–30+ minutes of runtime at full load.

Key Features

  • Valve-Regulated Lead Acid (VRLA) Chemistry: The replacement batteries are valve-regulated, non-spillable, and flame-retardant — meaning they can be installed in occupied IT spaces and equipment rooms without special ventilation requirements or hazardous materials handling. This matters when your maintenance window is tight and your electrician isn't available.
  • Auto-Detection of External Battery Cabinets: The GXT5 UPS automatically recognizes newly installed external battery modules without manual configuration. Technicians don't need to re-enter battery capacity or runtime data post-swap — the UPS recalibrates runtime estimates on its own, reducing the chance of misconfiguration after a maintenance event.
  • Intelligent Battery Health Management: The Liebert GXT5 provides continuous battery health status and replacement date prediction as part of its built-in management layer. Rather than running on a fixed calendar replacement schedule (which either replaces batteries too early or too late), you get data-driven alerts that flag actual degradation — so you replace on condition, not on assumption.
  • Rated Operating Temperature +32°F to +104°F (0°C to 40°C): The 40°C upper ceiling aligns with typical data closet and server room temperature ranges. Note that VRLA battery life degrades above 25°C at roughly 50% per 10°C rise — if your room consistently runs warm (above 77°F), factor that into your replacement interval expectations regardless of this service plan's coverage window.
  • 2-Year Base Service Coverage: The BAS2YR term provides a structured replacement cycle with Vertiv's PRO Refresh Plus service backing — relevant for sites that need documented maintenance records for compliance audits or facilities management sign-off.

Integration & Compatibility

The PBRGXT5X-192VBAT is validated for use with the following Vertiv Liebert GXT5 UPS models in their 192V external battery cabinet configurations:

  • Liebert GXT5-5000HVRT5UXLN — 5kVA rack/tower UPS
  • Liebert GXT5-6KL630RT5UXLN — 6kVA rack/tower UPS
  • Liebert GXT5-8000HVRT5UXLN — 8kVA rack/tower UPS
  • Liebert GXT5-10KHVRT5UXLN — 10kVA rack/tower UPS

Compatibility is confirmed for these four SKUs only. Do not apply this service plan to GXT5 models outside this list or to non-192V battery string configurations — incorrect battery voltage matching creates both a safety risk and a warranty issue. If you're running a different GXT5 variant, consult Vertiv's power protection service catalog for the matching refresh plan SKU.

Frequently Asked Questions

Q: Which Liebert GXT5 UPS models does the PBRGXT5X-192VBAT support?

A: This service plan is validated for four specific GXT5 models: GXT5-5000HVRT5UXLN, GXT5-6KL630RT5UXLN, GXT5-8000HVRT5UXLN, and GXT5-10KHVRT5UXLN — all in 192V external battery cabinet configurations. It is not compatible with GXT5 models outside this list or with different voltage configurations.

Q: What battery chemistry does the PBRGXT5X-192VBAT use?

A: The replacement batteries are valve-regulated, non-spillable, flame-retardant lead acid (VRLA). This chemistry is suitable for installation in occupied IT spaces without special ventilation requirements.

Q: Does the GXT5 UPS automatically recognize the new batteries after a PRO Refresh Plus replacement?

A: Yes. The Liebert GXT5 includes auto-detection of external battery cabinets, so the UPS reconfigures runtime estimates automatically after a battery swap — no manual recalibration required.

Q: What is the operating temperature range for this battery service plan?

A: The rated operating range is +32°F to +104°F (0°C to 40°C). Keep in mind that VRLA battery lifespan degrades at elevated temperatures, so facilities running consistently above 77°F (25°C) should plan for shorter effective battery life.

Q: How does the GXT5 predict battery replacement dates under this plan?

A: The Liebert GXT5 UPS provides battery health status monitoring and replacement date prediction as part of its onboard management. Rather than a fixed calendar schedule, the system flags degradation based on actual battery condition — allowing condition-based maintenance instead of time-based guesswork.

Jerry Tildsen
Jerry Tildsen

The PBRGXT5X-192VBAT is one of those service SKUs that looks simple on the surface but carries real operational weight — particularly the GXT5's onboard battery replacement date prediction, which changes how you staff and schedule UPS maintenance across a multi-site deployment. Instead of dispatching a tech on a fixed 3-year calendar and replacing batteries that still have capacity, you're responding to actual degradation signals. That's fewer wasted batteries and fewer surprise failures.

Technical Highlights:

  • VRLA Non-Spillable Chemistry: Flame-retardant, valve-regulated construction means these batteries can be serviced in occupied data closets and wiring rooms without triggering hazmat protocols — relevant when your maintenance windows happen during business hours.
  • Auto-Detection Post-Swap: The GXT5 recalibrates runtime estimates automatically after new batteries are installed. No manual capacity entry, no risk of a tech entering wrong Ah values and leaving the UPS reporting incorrect runtime to DCIM or SNMP monitoring.
  • 40°C Operating Ceiling: Aligns with most server room and edge compute temperature envelopes, but VRLA chemistry loses roughly half its rated life for every 10°C above 25°C — if your site runs warm, this is the number to track against your ambient temperature logs.

Deployment Considerations:

  • Confirm your GXT5 serial number maps to one of the four supported models (GXT5-5000HVRT5UXLN, GXT5-6KL630RT5UXLN, GXT5-8000HVRT5UXLN, or GXT5-10KHVRT5UXLN) before ordering — applying this plan to an out-of-scope GXT5 variant voids the service coverage.
  • The 192V string configuration is specific to extended-runtime setups; don't conflate this SKU with internal battery replacement plans for standard-runtime GXT5 units.

The PBRGXT5X-192VBAT is the right fit for facilities teams managing multiple GXT5 units across distributed edge sites — the kind of environment where condition-based battery monitoring and auto-detection after a swap materially reduce the per-site maintenance labor cost.

Specifications
Interface Options: Auto-detection of external battery cabinets
Protocols: Liebert® GXT5 provides battery health status and replacement date prediction for intelligent battery health management
Operating Temperature: +32 to +104 °F (0 to 40 °C)
General: Compatible with Liebert® GXT5-5000HVRT5UXLN, Liebert® GXT5-6KL630RT5UXLN, Liebert® GXT5-8000HVRT5UXLN and Liebert® GXT5-10KHVRT5UXLN, Liebert GXT5 UPS
UPS Topology: Battery Type: Valve-regulated, non-spillable, flame-retardant, lead acid
Q&A
Reviews

Vertiv GXT5 192VBAT - PBRGXT5X-192VBAT

$6,065.00
$4,158.99

RELATED PRODUCTS

Save $2,383.01
Vertiv PRO Refresh Plus GXT5 192VBAT BAS2YR - PBRGXT5-192VBAT
Add to Cart The item has been added

Vertiv PBRGXT5-192VBAT

Vertiv PRO Refresh Plus GXT5 192VBAT BAS2YR - PBRGXT5-192VBAT

N external battery cabinet designed to significantly extend the runtime of compatible Liebert GXT5 Uninterruptible Power Supply (UPS) units

    Usually Ships in 2-3 Weeks Free shipping over $499
    $7,583.00 $5,199.99 Save $2,383.01
    The item has been added Add to quote
    $7,583.00 $5,199.99 Save $2,383.01
    Save $2,383.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources