Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PBRGXT5X-48VBAT PRO Refresh Plus Multi GXT5 48V Battery Service Plan

Overview

The Vertiv PBRGXT5X-48VBAT is a 2-year PRO Refresh Plus battery service plan engineered specifically for the Liebert GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL 48V UPS systems. Rather than waiting for a battery failure to interrupt a critical load, this plan pairs scheduled replacement with the GXT5's built-in battery health management — giving facilities teams predictable maintenance windows instead of unplanned downtime. If you manage UPS runtime in a server room, edge datacenter, or critical infrastructure rack, this is the structured approach to battery lifecycle management that most sites should be running but aren't. For the broader Vertiv UPS and power protection catalog, the GXT5 family sits in the online double-conversion tier — the topology that delivers zero-transfer-time protection for sensitive equipment.

Key Features

  • Intelligent Battery Health Monitoring: The Liebert GXT5 UPS continuously tracks battery health status and projects replacement dates — so the PBRGXT5X-48VBAT service plan aligns scheduled replacements to actual battery condition rather than arbitrary calendar intervals. You avoid both premature swaps and the risk of running degraded cells into a real power event.
  • Auto-Detection of External Battery Cabinets: The GXT5 platform auto-detects attached external battery cabinets, meaning the health monitoring and replacement date prediction extend across the full battery string — not just the internal pack. Larger runtime configurations stay fully visible to the management layer.
  • Valve-Regulated Lead Acid (VRLA) Chemistry: The 48V string uses 2 × 4 × 12V × 9.0Ah valve-regulated, non-spillable lead acid cells. VRLA chemistry requires no electrolyte maintenance and poses no spillage risk in a rack environment — relevant for deployments in occupied spaces or facilities without hazmat protocols for flooded cells.
  • UL 1778 4th Edition and CSA 22.2 No. 107.1 Listed: Both the UPS platform and associated service components carry UL 1778 (the UPS safety standard) and CSA 22.2 No. 107.1 listings. For projects requiring code-compliant installations in the US and Canada, these listings satisfy the authority having jurisdiction without additional waivers.
  • +32 to +104°F (0 to 40°C) Operating Range: The 40°C upper limit covers most conditioned equipment rooms and wiring closets. Note that VRLA battery life degrades above 25°C — if your room runs consistently warm, factor ambient temperature into expected service intervals beyond what this plan covers.
  • Targeted Platform Compatibility: This plan is scoped exclusively to the GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL. That specificity matters — battery service contracts that span incompatible SKUs create fulfillment problems at replacement time. Verify your UPS model before purchasing. For related UPS systems outside the GXT5 1500/2000VA 48V range, a different service SKU applies.

Integration and Compatibility

The PBRGXT5X-48VBAT (often searched as PBRGXT5X 48VBAT) integrates directly with the GXT5 platform's battery management firmware — no additional software or communication modules are required to enable health status reporting. The auto-detection capability for external battery cabinets means multi-module runtime extensions are supported without manual configuration. This service plan is designed to work alongside standard power management practices in environments running the Liebert GXT5 in 2U rackmount configurations. For sites also running network-connected UPS monitoring, the GXT5's communication card slots remain unaffected by the battery service scope — UPS accessories and communication cards should be sourced separately based on your SNMP or USB monitoring requirements. When planning a full rack power strategy, pairing this service plan with a structured PDU deployment ensures both distribution and runtime protection are on coordinated maintenance cycles.

Frequently Asked Questions

Q: Which UPS models does the PBRGXT5X-48VBAT cover?

A: The PBRGXT5X-48VBAT is compatible exclusively with the Liebert GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL UPS systems. It is not applicable to other GXT5 variants or different voltage configurations.

Q: What battery type is covered under this service plan?

A: The plan covers the 48V battery string consisting of 2 × 4 × 12V × 9.0Ah valve-regulated, non-spillable lead acid (VRLA) cells used in the compatible GXT5 UPS models.

Q: Does the PBRGXT5X-48VBAT support external battery cabinet configurations?

A: Yes. The GXT5 UPS platform includes auto-detection of external battery cabinets, so the battery health monitoring and replacement date prediction extend to the full battery string including external runtime expansions.

Q: What safety certifications apply to this service plan and the associated UPS platform?

A: The Liebert GXT5 UPS platform is listed to UL 1778 4th Edition and CSA 22.2 No. 107.1, covering both US and Canadian safety requirements.

Q: What is the operating temperature range for the GXT5 UPS systems covered by this plan?

A: The operating temperature range is +32 to +104°F (0 to 40°C). Keep in mind that VRLA battery longevity is sensitive to sustained temperatures above 25°C — consistently warm environments will shorten effective battery service life.

Marty Allison
Marty Allison

The PBRGXT5X-48VBAT addresses a gap that bites a lot of facilities teams: the GXT5 UPS is doing continuous battery health tracking and projecting replacement dates, but without a structured service plan, that prediction just becomes a notification that nobody acts on until runtime degrades. Pairing this plan with the GXT5's built-in intelligence means you're scheduling replacement on real battery condition data — not a wall calendar.

Technical Highlights:

  • 2 × 4 × 12V × 9.0Ah VRLA string: Eight cells total in the 48V configuration — VRLA chemistry means no venting, no electrolyte checks, and no spill containment requirements in the rack. That simplifies install in occupied IT closets where flooded cell handling would be a compliance issue.
  • Replacement date prediction: The GXT5 firmware doesn't just flag a battery as bad — it predicts the replacement date ahead of failure. That lead time is what makes a proactive service plan actually actionable rather than reactive.
  • Auto-detection of external cabinets: If the GXT5 installation includes external battery modules for extended runtime, the platform detects them automatically. This service plan's scope needs to align with your full battery string — confirm with your Vertiv rep if external cabinets are in play.

Deployment Considerations:

  • This plan is hard-scoped to GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL. Pulling the UPS model number before purchasing is non-negotiable — other GXT5 VA ratings or voltage configs use different service SKUs.
  • The 40°C operating ceiling is adequate for most conditioned rooms, but VRLA cells degrade faster above 25°C ambient. If your equipment room runs warm without precision cooling, actual service intervals under this plan may be shorter than anticipated.

This plan is the right fit for edge datacenter and server room deployments running the GXT5 1500 or 2000VA in a 2U rackmount where the facilities team needs a defensible, documented battery maintenance cycle — particularly in regulated environments (healthcare, finance, government) where equipment maintenance records are subject to audit.

Specifications
Interface Options: Auto-detection of external battery cabinets
Protocols: Liebert GXT5 UPS provides battery health status and replacement date prediction for intelligent battery health management
Operating Temperature: +32 to +104 °F (0 to 40 °C)
General: Compatible with the GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL Liebert GXT5 UPS systems
Listings: UL 1778 4th edition and CSA 22.2 No. 107.1
UPS Topology: Battery type: Valve-regulated, non-spillable, lead acid; Battery quantity × V × rating: 2 × 4 × 12V × 9.0Ah
Q&A
Reviews

Vertiv GXT5 48VBAT - PBRGXT5X-48VBAT

$3,785.00
$2,595.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services