Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PBRGXT5-48VBAT-LF GXT5 48V Battery Replacement Service Plan

Overview

The Vertiv PBRGXT5-48VBAT-LF is a PRO Refresh Plus service plan that covers battery replacement for the Liebert GXT5 UPS systems — specifically the GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL. If you're running either of those 2U rack UPS units in a data center, server room, or network closet, battery degradation is a when-not-if situation. This plan addresses that directly by bundling a scheduled battery swap with the GXT5's built-in health-monitoring intelligence, so you're not reacting to a low-battery alarm at 2 AM — you're ahead of it. The PBRGXT5-48VBAT-LF (often searched as PBRGXT5 48VBAT LF) is designed for operations that need predictable maintenance windows, not unplanned downtime events.

Key Features

  • Intelligent Battery Health Management: The Liebert GXT5 UPS continuously monitors battery health status and generates replacement date predictions — not just a capacity percentage, but an actual forecast. That means facilities teams can schedule this service during a planned maintenance window rather than scrambling after an unexpected failure flags on the UPS front panel or SNMP trap.
  • Valve-Regulated Lead Acid (VRLA) Chemistry: The replacement batteries are valve-regulated, non-spillable lead acid — the standard for rack UPS deployments where spill containment and orientation flexibility matter. No electrolyte maintenance, no venting requirements beyond standard rack ventilation. Two battery strings of 4 × 12V × 9.0Ah cells means the 48V nominal bus is maintained with redundancy across the string pairs.
  • Auto-Detection of External Battery Cabinets: The GXT5 platform supports auto-detection of external battery cabinet attachments, and this service plan is designed within that architecture. If your deployment has grown to include extended runtime cabinets, the UPS's battery management layer recognizes the full string automatically — no manual capacity entry or firmware tricks required.
  • UL 1778 (4th Edition) and CSA 22.2 No. 107.1 Listed: Both the UPS platform and associated battery service meet UL 1778 4th edition and CSA 22.2 No. 107.1 requirements. For facilities requiring compliance documentation — healthcare, financial services, data centers under SOC 2 audit — this listing covers the battery replacement work within the same certified system boundary.
  • Operating Temperature Range +32°F to +104°F (0°C to 40°C): The service plan covers operation within a standard commercial temperature envelope. At the high end — 40°C ambient — battery life accelerates its decline, so facilities running warm aisles should factor that into replacement cycle planning. This range is consistent with typical server room and network closet environments, but edge deployments with less climate control warrant closer monitoring intervals.
  • Targeted Compatibility — GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL Only: This plan is explicitly scoped to two SKUs. If you're running a different GXT5 variant or a GXT3/GXT4 unit, this service does not apply. Verify your UPS model number before ordering — mismatched service plans create fulfillment delays and coverage gaps.

Integration and Compatibility

The PBRGXT5-48VBAT-LF service plan integrates directly with the Liebert GXT5 UPS management layer. The GXT5 platform exposes battery status via its built-in monitoring interface, and the predictive replacement date feature feeds into SNMP-capable NMS platforms and the Vertiv Environet Alert monitoring ecosystem. If your data center runs a centralized infrastructure monitoring stack — whether Vertiv-native or a third-party NMS via SNMP MIB — the battery health data flows through the same channel as the rest of your UPS telemetry. No separate monitoring agent or secondary hardware is required for the health prediction feature to function. The 2 × 4-cell, 48V battery architecture means the replacement procedure is a defined, repeatable task that trained facilities staff can execute within a planned outage window. Pair this plan with a review of your power and UPS infrastructure to ensure all critical loads are covered under a consistent maintenance schedule. For teams managing larger Vertiv deployments, the Vertiv product catalog includes the full GXT5 line alongside compatible accessories and monitoring hardware.

Frequently Asked Questions

Q: Which UPS models does the PBRGXT5-48VBAT-LF battery service plan cover?

A: The PBRGXT5-48VBAT-LF is compatible exclusively with the Liebert GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL UPS systems. It is not applicable to other GXT5 variants or earlier GXT-series units.

Q: What battery type is replaced under this service plan?

A: The plan covers valve-regulated, non-spillable lead acid (VRLA) batteries configured as 2 strings of 4 × 12V × 9.0Ah cells, maintaining the 48V nominal battery bus used by the GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL.

Q: Does the GXT5 UPS provide advance notice before battery replacement is needed?

A: Yes. The Liebert GXT5 platform includes intelligent battery health management that monitors battery condition and generates a replacement date prediction — giving facilities teams advance notice to schedule maintenance proactively rather than reacting to a failure event.

Q: What certifications apply to this service plan and the associated UPS platform?

A: The Liebert GXT5 UPS platform, within which this battery service operates, is listed to UL 1778 4th edition and CSA 22.2 No. 107.1.

Q: What is the operating temperature range for the GXT5 UPS covered under this plan?

A: The covered UPS systems operate within a +32°F to +104°F (0°C to 40°C) ambient temperature range. Environments consistently running near the upper limit will accelerate battery wear and may warrant more frequent health checks.

Q: Does this plan support UPS deployments with external battery cabinets?

A: The GXT5 platform supports auto-detection of external battery cabinets. The PBRGXT5-48VBAT-LF service is designed within that architecture, though coverage scope for extended-runtime configurations should be confirmed with Vertiv support at time of service scheduling.

Eden Phillips
Eden Phillips

The PBRGXT5-48VBAT-LF stands out from generic battery replacement programs because it pairs the physical swap with the GXT5's predictive health monitoring layer — specifically the replacement date forecasting built into the Liebert GXT5 firmware. That distinction matters operationally: instead of calendar-based guesswork or waiting for a capacity alarm, the UPS itself tells you when the 2 × 4 × 12V × 9.0Ah VRLA string is approaching end-of-life, giving your team a real scheduling window.

Technical Highlights:

  • VRLA Battery Configuration (2 × 4 × 12V × 9.0Ah): Non-spillable construction means no special containment or orientation restrictions in the rack — important in dense 2U deployments where airflow and cable management already constrain physical access.
  • Predictive Replacement Date: The GXT5 battery health management engine generates an actual date estimate, not just a percentage readout. For teams managing dozens of rack UPS units across a facility, this is the difference between proactive scheduling and reactive firefighting.
  • UL 1778 4th Edition / CSA 22.2 No. 107.1 Listing: Both listings are current-edition, which matters for facilities undergoing infrastructure audits — older UL 1778 editions have been superseded, and auditors increasingly ask for 4th edition compliance specifically.

Deployment Considerations:

  • Compatibility is hard-gated to the GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL — confirm your exact UPS model number before ordering. A GXT5-3000 or any earlier GXT generation will not qualify under this plan, and mismatched orders create fulfillment delays.
  • The 40°C upper operating limit is a real-world constraint in edge or IDF closets with poor climate control. At sustained high ambient temps, VRLA batteries degrade faster than the health monitoring model may anticipate — factor in environmental conditions when projecting replacement intervals.

This plan is the right fit for IT and facilities teams managing GXT5-1500 or GXT5-2000 units in regulated environments — healthcare data rooms, financial services infrastructure closets, or any facility where a documented, listing-compliant battery maintenance record is part of the compliance posture.

Specifications
Interface Options: Auto-detection of external battery cabinets
Protocols: Liebert GXT5 UPS provides battery health status and replacement date prediction for intelligent battery health management
Operating Temperature: +32 to +104 °F (0 to 40 °C)
General: Compatible with the GXT5-1500LVRT2UXL and GXT5-2000LVRT2UXL Liebert GXT5 UPS systems
Listings: UL 1778 4th edition and CSA 22.2 No. 107.1
UPS Topology: Battery type: Valve-regulated, non-spillable, lead acid; Battery quantity × V × rating: 2 × 4 × 12V × 9.0Ah
Q&A
Reviews

Vertiv GXT5 48VBAT - PBRGXT5-48VBAT-LF

$5,390.00
$3,696.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments