Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PBRGXT5-192VBAT PRO Refresh Plus GXT5 192V Battery Cabinet Service

Overview

The Vertiv PBRGXT5-192VBAT is the PRO Refresh Plus service bundle for the Liebert® GXT5 192V external battery cabinet — a proactive battery replacement and coverage package designed for sites running the GXT5-5000HVRT5UXLN, GXT5-6KL630RT5UXLN, GXT5-8000HVRT5UXLN, or GXT5-10KHVRT5UXLN UPS platforms where unplanned battery failure is not an option. Rather than waiting for a battery alarm mid-shift, this service addresses the battery before it becomes a liability: valve-regulated, non-spillable, flame-retardant lead-acid cells replaced on a defined cycle, paired with a 2-year coverage term (BAS2YR) that gives procurement a fixed cost line and operations a documented refresh date.

If your GXT5 runtime strategy depends on the 192V external battery cabinet, PBRGXT5-192VBAT (often searched as PBRGXT5 192VBAT) is the structured way to maintain that strategy across the service interval rather than gambling on aging cells.

Key Features

  • Valve-Regulated, Non-Spillable, Flame-Retardant Battery Chemistry: VRLA cells eliminate the electrolyte spill risk associated with flooded lead-acid designs — relevant in raised-floor data rooms and telecom closets where a battery leak can damage adjacent infrastructure. The flame-retardant designation adds another layer of protection in occupied facilities where fire suppression is a design constraint.
  • Intelligent Battery Health Management via Liebert GXT5 UPS: The GXT5 UPS continuously monitors battery health and projects replacement dates — so the PBRGXT5-192VBAT refresh cycle is informed by actual battery condition data, not just a calendar estimate. Sites that run the GXT5 with its native battery management can time this service engagement based on the UPS's own replacement-date prediction rather than guessing.
  • Auto-Detection of External Battery Cabinets: The GXT5 UPS auto-detects attached external battery cabinets and adjusts runtime calculations accordingly. This means after the refresh is complete, the UPS re-characterizes the battery string automatically — no manual reconfiguration of cabinet count or capacity required.
  • Defined 2-Year Coverage Term (BAS2YR): The BAS2YR suffix locks in a two-year service window. For facilities managers and IT procurement teams, that translates to a predictable maintenance budget line and a documented compliance record — both useful when auditing power resilience for regulated environments (healthcare, financial, colocation).
  • Operating Temperature Range +32°F to +104°F (0°C to 40°C): Matches the standard data center and IDF/MDF temperature envelope. If your battery room exceeds 40°C during peak summer load, battery life will degrade faster than the refresh schedule accounts for — factor HVAC capacity into deployment planning.
  • Compatible with High-Capacity GXT5 UPS Models: Specifically validated against the GXT5-5000HVRT5UXLN, GXT5-6KL630RT5UXLN, GXT5-8000HVRT5UXLN, and GXT5-10KHVRT5UXLN — the 5kVA through 10kVA high-voltage rack/tower configurations that use the 192V external cabinet for extended runtime. If your site runs a different GXT5 SKU, verify cabinet compatibility before ordering.

Integration & Compatibility

The PBRGXT5-192VBAT is purpose-built for the Vertiv Liebert GXT5 UPS platform. It is not a universal battery service — it targets the specific 192V external battery cabinet variant used with the high-capacity GXT5 models listed above. Compatibility is enforced at the hardware level: the GXT5 auto-detects cabinet presence and validates the battery string, so a mismatched cabinet or incorrect service SKU will be flagged by the UPS management interface.

Sites running UPS systems alongside structured network infrastructure should confirm that the 192V battery cabinet is the correct external module for their specific GXT5 model before scheduling service. The Liebert® GXT5 battery health management system — which projects replacement dates — is the primary tool for determining when the PBRGXT5-192VBAT refresh engagement should be triggered within the 2-year window.

For broader power protection planning, consider pairing GXT5 runtime extension with appropriate power distribution and monitoring infrastructure to ensure visibility across the full power chain. A surge protection layer upstream of the UPS remains good practice regardless of battery refresh cadence.

Frequently Asked Questions

Q: Which Vertiv GXT5 UPS models is the PBRGXT5-192VBAT compatible with?

A: The PBRGXT5-192VBAT is validated for use with the Liebert® GXT5-5000HVRT5UXLN, GXT5-6KL630RT5UXLN, GXT5-8000HVRT5UXLN, and GXT5-10KHVRT5UXLN — the 5kVA to 10kVA high-voltage rack/tower models that use the 192V external battery cabinet. It is not a universal GXT5 service SKU; verify your specific model before ordering.

Q: What type of batteries are replaced under this service?

A: The 192V external battery cabinet uses valve-regulated, non-spillable, flame-retardant lead-acid (VRLA) batteries. This chemistry eliminates electrolyte spill risk and meets flame-retardant requirements for occupied and raised-floor facilities.

Q: What does the BAS2YR suffix mean on the PBRGXT5-192VBAT?

A: BAS2YR denotes a 2-year service coverage term. It defines the window during which the PRO Refresh Plus battery replacement service applies, providing a fixed cost and documented maintenance record for the battery cabinet.

Q: Does the GXT5 UPS automatically recognize the refreshed battery cabinet after service?

A: Yes. The Liebert® GXT5 features auto-detection of external battery cabinets and will re-characterize the battery string following a refresh without requiring manual reconfiguration of cabinet count or capacity settings.

Q: What is the operating temperature range for the GXT5 192V battery cabinet?

A: The rated operating temperature is +32°F to +104°F (0°C to 40°C). Sustained ambient temperatures above 40°C will accelerate battery aging and may shorten effective service life between refresh cycles.

Q: How does the GXT5 know when a battery refresh is needed?

A: The Liebert® GXT5 UPS includes battery health management that tracks cell condition and provides replacement date predictions. This allows facilities teams to schedule the PBRGXT5-192VBAT service proactively based on actual battery telemetry rather than a fixed calendar interval alone.

Marty Allison
Marty Allison

The PBRGXT5-192VBAT lands in a specific and often-overlooked gap in UPS lifecycle planning: the external battery cabinet refresh. Most sites budget for the UPS itself but treat the 192V battery cabinet as a set-and-forget component until a low-battery alarm forces an emergency service call. This PRO Refresh Plus service is designed to prevent exactly that scenario — the BAS2YR term creates an accountable maintenance window for the valve-regulated lead-acid string that the GXT5 platform depends on for extended runtime.

Technical Highlights:

  • VRLA Battery Chemistry: Valve-regulated, non-spillable, flame-retardant cells are the correct choice for data rooms and telecom closets — no ventilation requirements for hydrogen off-gassing that flooded-cell designs mandate, and the flame-retardant designation matters in facilities with strict fire code compliance requirements.
  • GXT5 Battery Health Management: The Liebert® GXT5 UPS tracks cell condition and predicts replacement dates — which means the PBRGXT5-192VBAT refresh can be scheduled against actual battery telemetry, not just elapsed time. That's a meaningful operational advantage over time-based-only service contracts.
  • Auto-Detection of External Cabinets: Post-refresh, the GXT5 auto-detects the battery cabinet and recalculates runtime automatically. No technician intervention needed to update cabinet count or reconfigure capacity — the UPS handles it at the protocol level.

Deployment Considerations:

  • This service SKU is not a physical product you install — it is a service engagement covering the 192V external battery cabinet on the four validated GXT5 high-voltage models. Confirm your exact GXT5 model number before placing the order; ordering this against a non-listed GXT5 variant will result in a mismatched service agreement.
  • Battery life is temperature-sensitive: the +32°F to +104°F (0°C to 40°C) operating range assumes controlled data center conditions. If your battery room runs consistently above 35°C due to cooling shortfalls, expect the actual battery life to fall short of the service interval — factor that into your refresh scheduling and HVAC planning.

The PBRGXT5-192VBAT is the right choice for facilities running 5kVA–10kVA GXT5 high-voltage UPS deployments with 192V extended-runtime cabinets where a documented, proactive battery refresh cycle is part of the site's power resilience plan — particularly in regulated environments (healthcare, financial services, colocation) where battery maintenance records are a compliance requirement, not just good practice.

Specifications
Dimensions: 130 mm
Interface Options: Auto-detection of external battery cabinets
Protocols: Liebert® GXT5 provides battery health status and replacement date prediction for intelligent battery health management
Operating Temperature: +32 to +104 °F (0 to 40 °C)
General: Compatible with Liebert® GXT5-5000HVRT5UXLN, Liebert® GXT5-6KL630RT5UXLN, Liebert® GXT5-8000HVRT5UXLN and Liebert® GXT5-10KHVRT5UXLN, Liebert GXT5 UPS
UPS Topology: Battery Type: Valve-regulated, non-spillable, flame-retardant, lead acid
Q&A
Reviews

Vertiv PRO Refresh Plus GXT5 192VBAT BAS2YR - PBRGXT5-192VBAT

$7,583.00
$5,199.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources