Panduit
SKU: F92RLU1U1ONM014
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit's F92RPU1U1ONM013 Opti-Core patch cord delivers OS2-grade single-mode performance in a 13-meter plenum-rated assembly purpose-built for high-density data center and telecom room deployments. The LC duplex uniboot connector design cuts panel footprint in half compared to traditional duplex LC cables while the integrated pull-boot mechanism streamlines moves, adds, and changes in congested pathways. Factory-terminated with optimized insertion loss and full TIA/ISO compliance, this yellow-jacketed cable is engineered for technicians running pre-terminated fiber links in entrance facilities, equipment distribution areas, and MPO-to-LC breakout applications where installation speed and pathway efficiency are non-negotiable.
Single-mode fiber at OS2 specification is the backbone of enterprise and service-provider networks requiring multi-kilometer reach or future-proofing for 40GBASE-LR4, 100GBASE-LR4, and coherent optics. The F92RPU1U1ONM013's 9 μm core diameter supports wavelengths from 1310 nm to 1550 nm with attenuation under 0.4 dB/km at 1310 nm and 0.3 dB/km at 1550 nm, enabling 10G transmission beyond 10 km and 100G transmission beyond 2 km when paired with compliant transceivers. Panduit's Opti-Core manufacturing process pre-polishes connectors to sub-50nm geometry and inspects every fiber end-face under interferometry to eliminate return-loss failures that plague field-terminated assemblies. Insertion loss is optimized at the factory and documented on the pull-tab label — installers can verify link budgets without field testing, cutting commissioning time on spine-leaf fabrics and storage-area networks where hundreds of links turn up simultaneously.
The uniboot connector body consolidates both fibers into a single push-pull housing, cutting the width required at LC duplex adapter panels from 13.6 mm down to 6.25 mm — the same footprint as a single simplex LC. In 1U breakout panels serving 96-fiber MPO trunks, this density improvement raises per-rack-unit port count from 24 duplex links to 48 duplex links without adapter stacking or reduced bend-radius margins. The integrated pull-boot extends 12 mm beyond the connector latch, giving technicians a positive grip point even when the cable is zip-tied within 50 mm of the panel — a common condition in vertically oriented cable managers and zero-U pass-through ducts. For polarity correction, the boot unclips without tools and the duplex connector rotates 180° to swap A/B fiber positions, eliminating the need to re-pull cables when transceiver port assignments don't match patch-panel keying.
Plenum rating under UL 910 (OFNP per NEC Article 770) authorizes installation in return-air plenums, suspended ceilings, and raised-floor voids without metallic or non-metallic conduit, a requirement for ceiling-based horizontal distribution in commercial office buildings and above-rack cable trays in co-location data centers. The 13-meter length suits rack-to-rack runs in the same hot or cold aisle, end-of-row aggregation switch uplinks, and telecom room cross-connects between patch panels and active equipment mounted in adjacent bays. The yellow PVC jacket is flame-rated to 150°C continuous and resists UV degradation under high-intensity LED rack lighting, maintaining jacket integrity through repeated cleaning cycles with isopropyl alcohol wipes. Panduit ships the assembly in cartons of 10 with individually bagged cables and adhesive port labels for as-built documentation.
Compliance spans ISO/IEC 11801 generic cabling (Class B fiber), TIA-568-C.3 (optical fiber cabling components), TIA-604-3 (FOCIS-3 SC/LC connector intermateability), TIA-604-10 (FOCIS-10 duplex LC), and RoHS Directive 2002/95/EC (hazardous substance restriction). Each connector is keyed to IEC 61754-20 mechanical interface standards for LC duplex, ensuring cross-vendor adapter compatibility with Corning, Commscope, Leviton, and Siemon infrastructure. This patch cord is engineered for integrators running structured cabling systems in financial trading floors, healthcare imaging networks, and stadium distributed antenna systems where insertion loss, flame rating, and standards compliance are all specified in the engineer-of-record's drawings and tested during final acceptance.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price