Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: F92RLU2U2ONM9.5
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 0% OFF

Panduit F92RLU2U2ONM9.5 OS2 LC Uniboot Fiber Cable 31ft

Panduit F92RLU2U2ONM9.5 OS2 Single-Mode Fiber Patch Cable The Panduit F92RLU2U2ONM9.5 delivers OS2 single-mode fiber connectivity in a compact LC/LC U…

$78.02 $77.99 SAVE $0

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit F92RLU2U2ONM9.5 OS2 LC Uniboot Fiber Cable 31ft

$78.02
$77.99

Overview

SKU: F92RLU2U2ONM9.5
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92RLU2U2ONM9.5 OS2 Single-Mode Fiber Patch Cable

The Panduit F92RLU2U2ONM9.5 delivers OS2 single-mode fiber connectivity in a compact LC/LC Uniboot configuration designed for high-density datacenter and campus backbone deployments. This 9.5-meter (31-foot) duplex patch cord features APC (Angled Physical Contact) polish, LSZH jacket construction, and optimized insertion loss performance for 10GBASE-LR, 40G, and 100G Ethernet applications. The 2mm cable diameter and space-saving Uniboot design address the tight-routing and port-density challenges commercial integrators face when building out fiber infrastructure in network closets, server rooms, and IP surveillance recording environments.

Key Features

  • OS2 9/125µm single-mode fiber supports transmission distances up to 10 km at 10 Gbps, 40 km at 1 Gbps
  • LC/LC Uniboot connector design occupies half the footprint of traditional duplex LC — critical for high-density switch and media converter installations
  • APC (8° angled) polish delivers <-60 dB return loss, minimizing back-reflection in DWDM, CWDM, and long-haul links
  • LSZH (Low Smoke Zero Halogen) jacket meets IEC 60332-1 and plenum-alternative building code requirements
  • 2.0mm cable diameter enables tight-radius routing in cable trays, vertical managers, and patch-panel rear clearances
  • Optimized insertion loss specification ensures margin for future link budget degradation
  • 9.5-meter length suits typical cross-connect and equipment-to-MDA (Main Distribution Area) runs
  • Pull-boot strain relief protects connector ferrule from damage during installation and moves

The F92RLU2U2ONM9.5's OS2 single-mode fiber is the standard choice for structured cabling systems requiring multi-gigabit bandwidth over distances beyond 300 meters — datacenter spine-leaf architectures, campus building-to-building links, and centralized IP surveillance storage networks where NVRs aggregate streams from dozens of remote cameras. APC polish is mandatory for passive optical LAN (POL) deployments, coherent optics modules, and any application where laser-based transceivers demand return loss better than -55 dB. The angled endface directs reflected light into the cladding rather than back toward the source, protecting sensitive QSFP28 and SFP+ optics from performance degradation. Standard UPC (Physical Contact) polish reflects 4-5% of incident light; APC reduces that to <0.0001%, which matters when you're chaining multiple fiber spans or operating at the edge of a transceiver's receive sensitivity.

Panduit's Uniboot LC design solves the port-density crisis in 1RU 48-port switches and high-speed media converter shelves. Traditional duplex LC patch cords present two separate 1.25mm ferrules side-by-side; a Uniboot connector houses both ferrules in a single compact body that's field-reversible for polarity correction. When you're installing a 10G link between a PoE switch's SFP+ uplink and a fiber backbone, the Uniboot form factor lets you pack twice as many connections into the same rack width — and the integrated pull-tab makes add/move/change work faster in live environments where you can't afford to disturb adjacent links. The LSZH jacket is specified for installations where local fire codes prohibit PVC — data centers in EMEA, healthcare facilities, and transportation hubs where smoke toxicity and corrosivity are life-safety concerns. LSZH doesn't generate halogen acids (hydrochloric, hydrofluoric) when burned, protecting sensitive electronics in the same room and reducing evacuation risk during a fire event.

The 2.0mm cable diameter is a deliberate engineering trade-off: slightly larger than 1.6mm "zipcord" fiber (which uses 900µm buffered fibers), but more robust under bend stress and easier to route through cable-management fingers without kinking. In practice, this means the F92RLU2U2ONM9.5 survives the 25mm bend radius you encounter wrapping around vertical managers and patch-panel sides, while thinner constructions risk exceeding minimum bend radius and inducing macrobend attenuation. The 9.5-meter length is a datacenter-standard span for cross-connects within a single row or between adjacent hot/cold aisles — long enough to route cleanly without excess slack, short enough to avoid the signal budget waste of over-provisioned cables. When you're installing fiber links in a Milestone or Genetec recording cluster with SFP+ NICs, or interconnecting Axis Q-line cameras to fiber media converters in a campus deployment, this length hits the sweet spot for server-rack-to-network-rack and rack-to-wall-mount scenarios.

This patch cord is manufactured to TIA-568-C.3 and IEC 61754-20 industry standards for LC connectors and OS2 fiber, with factory testing to ensure insertion loss ≤0.35 dB and return loss ≥-60 dB (APC) per channel. Panduit's quality control process includes endface inspection at 400x magnification to detect scratches, contamination, and ferrule geometry defects before the cable leaves the facility — critical when you're deploying hundreds of links and can't afford field failures that require truck rolls and re-termination. The pull-boot strain relief is molded onto the connector body (not a separate clip-on component), so it won't pop off during installation or when you're pulling slack through a cable tray. For integrators building out 10GBASE-LR surveillance backbones, 40G aggregation uplinks, or POL fiber-to-the-desktop installations, this cable provides the connector density, bend performance, and safety compliance commercial environments demand without the cost premium of specialty armored or outdoor-rated constructions.

Specifications
Product Type: Fiber Optic Patch Cable
Fiber Type: OS2 Single-Mode 9/125µm
Connector Type A: LC Uniboot APC
Connector Type B: LC Uniboot APC
Polish Type: APC (Angled Physical Contact, 8°)
Cable Length: 9.5 meters (31 feet)
Cable Diameter: 2.0mm
Jacket Material: LSZH (Low Smoke Zero Halogen)
Configuration: Duplex
Insertion Loss: ≤0.35 dB (typical, optimized)
Return Loss: ≥-60 dB (APC)
Minimum Bend Radius: 25mm (installed)
Connector Boot: Pull-boot strain relief
Operating Temperature: -20°C to +70°C
Compliance: TIA-568-C.3, IEC 61754-20, IEC 60332-1
Application: 10GBASE-LR, 40G/100G Ethernet, DWDM, CWDM, POL
Color: Aqua (typical OS2 jacket color)
Connectivity: LC to LC
Type: Fiber Patch Cable
Durability: LSZH Jacket
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources