Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv I10401 30A Vertical Rack PDU, Basic Upgradeable, 36-Outlet

Overview

The Vertiv I10401 is a 70-inch vertical rack PDU built for data center and server room deployments where you need reliable 30A power distribution today with the option to add metering or monitoring later — without pulling the unit from the rack. Part of the Vertiv PowerIT rPDU line, it ships as a basic unit under model number MN01X4W1-36MR99-3TL14A0A10-S, but the Geist Upgradeable hot-swap architecture means you can slot in an Interchangeable Monitoring Device (IMD) and convert it to a metered or fully monitored PDU at any point, entirely without downtime.

Every I10401 is 100% factory-tested before shipment and carries a 5-year limited warranty — a longer coverage window than most competing PDU lines at this price tier. It's TAA compliant and Buy American Act (COTS) compliant, which matters for federal, defense, and education deployments with domestic-sourcing requirements.

Key Features

  • 36 total outlets across three receptacle types: 20 IEC C13, 4 IEC C19, and 12 NEMA 5-20R. The C13/C19 mix handles standard 1U/2U servers and high-draw devices like high-density switches or UPS bypass loads; the 12 NEMA 5-20R outlets serve 120V peripherals — KVM switches, console servers, remote access cards — without needing a separate low-voltage strip.
  • 30A / 5.7kW at 208V input: Sized for high-density rack builds. At 208V, 5.7kW of load capacity supports a fully populated rack of mid-range 1U servers or a mixed compute/storage shelf without breaker contention. The NEMA L14-30P twistlock plug prevents accidental disconnection on a live circuit.
  • Dual 20A double-pole magnetic breakers: Each breaker protects half the C13 load (10 outlets per breaker) and half the C19 load (2 per breaker), so a downstream fault trips one breaker and takes down half the rack at most — not everything. Magnetic trip is faster and more repeatable than thermal under high-cycle environments.
  • NEMA 5-20R outlets wired for 120V: The 12 duplex 5-20R positions run at 120V, isolated from the 208V C13/C19 circuit. This lets you power 120V-only devices in the same rack without step-down adapters — particularly useful in mixed-voltage North American deployments.
  • Geist hot-swap IMD slot (upgradeable without downtime): The defining feature of this product category. If your facility's power monitoring requirements change — or if you're pre-staging PDUs before a DCIM rollout — you can add an IMD module later without replacing the unit. This is meaningful when you're purchasing 20+ PDUs for a build-out and don't yet have a monitoring platform selected.
  • Vertical 70-inch / 1778mm chassis: Mounts in a standard 42U or 47U rack in a vertical zero-U position. Toolless mounting hardware accommodates center-to-center spacing of 61.25 inches or 64.75 inches — compatible with most major rack form factors including APC, Vertiv, Middle Atlantic, and open-frame.
  • 10-foot / 3-meter power cord with bottom-front entry: Bottom-front power entry routes the whip toward the floor PDU or floor busway without sharp bends. 10/4 wire gauge on a 30A circuit is correctly rated — no derating concerns at full load. 10 feet of reach handles most aisle-side power distribution layouts without extension cords.
  • Heavy steel powder-coat chassis, max operating temp 60°C / 140°F: The steel enclosure handles the thermal stress of densely loaded racks and hot-aisle containment environments where ambient air temps can run 45–55°C without issue.
  • UL & c-UL Listed (62368-1), RoHS, FCC Part 15 Class A: UL 62368-1 is the current audio/video and IT equipment safety standard — relevant for AHJ signoff in data centers and colocation facilities. FCC Part 15 Class A conformance limits RF emissions in commercial/industrial environments.

Integration and Compatibility

The I10401 works in any standard server rack or cabinet that accepts vertical zero-U PDU mounting. The dual mounting positions (61.25-inch and 64.75-inch center-to-center) cover the two predominant rack post configurations. The L14-30P input plug mates with standard 30A 120/208V twist-lock receptacles found on most raised-floor and overhead busway distribution systems in North American data centers.

For facilities running a DCIM or branch-circuit monitoring platform — such as power management systems from Vertiv or third parties — the IMD upgrade path is the key decision factor here. Rather than ordering a pre-monitored PDU at higher upfront cost, you can deploy I10401 units across a build-out and upgrade to metered or monitored IMDs selectively as monitoring infrastructure comes online. This staged approach is common in phased colocation builds and edge deployments.

Frequently Asked Questions

Q: Can the I10401 be upgraded to a monitored or metered PDU without replacing the unit?

A: Yes. The I10401 ships with no monitoring, but the Geist Upgradeable architecture includes a hot-swap IMD slot. You can insert a compatible Interchangeable Monitoring Device (IMD) at any time to add outlet-level metering or full environmental monitoring without removing or replacing the PDU chassis.

Q: What is the warranty on the I10401?

A: Vertiv covers the I10401 with a 5-year limited warranty, which is longer than most PDU competitors at this tier. Warranty terms are detailed in Vertiv's official product documentation.

Q: Is the I10401 TAA compliant?

A: Yes. The I10401 is manufactured in the USA and is both TAA compliant and Buy American Act (COTS) compliant, making it eligible for federal, defense, and education procurement with domestic-sourcing requirements.

Q: What input plug does the I10401 use, and what panel circuit does it require?

A: The I10401 uses a NEMA L14-30P twistlock plug and requires a 30A, 120/208V circuit — the standard for a dedicated 30A branch circuit in a North American data center. The 10-foot/3-meter cord provides adequate reach in most aisle-side layouts.

Q: How are the outlets distributed across breakers on the I10401?

A: The I10401 uses two 20A double-pole magnetic breakers. Each protects 10 of the 20 IEC C13 outlets (in banks of 5) and 2 of the 4 IEC C19 outlets. The 12 NEMA 5-20R outlets are split 6 per breaker. A fault on one breaker affects half the rack load at most.

Q: Does the I10401 fit in standard third-party racks, not just Vertiv enclosures?

A: Yes. The toolless vertical mounting hardware supports center-to-center post spacing of 61.25 inches and 64.75 inches, which covers most major North American rack form factors — including open-frame, two-post, and four-post enclosed cabinets from various manufacturers.

Marty Allison
Marty Allison

The I10401 is one of those PDUs I actually recommend for phased deployments — specifically because of the dual 20A magnetic breaker layout protecting 36 outlets across three receptacle types. When you're pre-staging a build and your monitoring platform isn't finalized yet, buying a basic upgradeable unit at this price point and hot-swapping an IMD later is a cleaner approach than locking in a monitored PDU from a vendor whose DCIM integration you haven't validated.

Technical Highlights:

  • 36 mixed outlets, three voltage classes: 20 C13 and 4 C19 at 208V for server loads, plus 12 NEMA 5-20R at 120V for peripherals — all in one 70-inch vertical strip. Eliminates the second low-voltage strip most integrators bolt to the side of the rack for KVM and console gear.
  • Dual 20A magnetic breakers: Magnetic trip characteristics beat thermal breakers in high-cycle environments — faster, more repeatable response and no thermal derating after repeated trips. Each breaker covers half the C13 bank (10 outlets) independently, so a downstream fault is contained.
  • TAA + Buy American Act COTS compliant: USA-manufactured and verified against both requirements. If your project is federally funded or goes through a GSA schedule, this clears a procurement gate that eliminates a lot of competing units at this form factor.

Deployment Considerations:

  • The L14-30P plug requires a dedicated 30A 120/208V branch circuit at the panel. Confirm your floor PDU or busway tap has a compatible 30A twist-lock receptacle before ordering — substituting a 30A straight-blade circuit requires an adapter that adds a failure point at the whip.
  • Bottom-front power entry works cleanly in hot-aisle/cold-aisle containment setups where the cord routes downward to a raised-floor distribution point, but it's awkward in overhead busway installs where the cord needs to run upward — measure your cable management path before committing.

Best fit: phased colocation build-outs and edge data rooms where you want the flexibility to upgrade to monitored power later without re-racking. If you need outlet-level monitoring on day one, budget for the IMD module upfront — the chassis is ready for it, but it doesn't ship included.

Specifications
Part Number: I10401
Model Number: MN01X4W1-36MR99-3TL14A0A10-S
Category: Basic Upgradeable
Power Configuration: 30A, 120/208V, 5.7kW
Physical Configuration: 70in / 1778mm, Vertical
Monitoring: No Monitoring (Upgradeable)
Plug Form: L14-30P
Receptacle IEC C13 Quantity: 20
Receptacle IEC C19 Quantity: 4
Receptacle NEMA 5-20R Quantity: 12
Input Quantity: 1
Voltage: 100-120/200-240V
Current: 30A
Load Capacity: 5.7kW (208V)
Frequency: 50/60Hz
Over Current Protection: 20A Double Pole Magnetic Breakers
Power Cable Wire Gauge: 10/4
Power Cable Length: 10ft / 3m
Power Entry Location: Bottom Front
Plug Type: NEMA L14-30P Twistlock
Total Receptacle Quantity: 36
Maximum Operating Temperature: 60C / 140F
Chassis Dimensions: 70in x 2in x 2in
Shipped Weight: 17lbs (7.71kg)
Product Warranty: 5-year limited warranty
Agency Approvals: UL & c-UL Listed 62368-1, RoHS Compliant, FCC Part 15 Class A
Q&A
Reviews

Vertiv MN01X4W1-36MR99-3TL14A0A10-S - I10401

$1,171.00
$802.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources