Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FPO75/150-C8D8E6S-VZ01
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty
Write a Review

Lifesafety Power FPO75/150-C8D8E6S-VZ01 75W power supply 6A/12V

Lifesafety Power FPO75/150-C8D8E6S-VZ01 Dual Output Power Supply with Relay Lock Control Overview The FPO75/150-C8D8E6S-VZ01 is a compact, dual-output…

$2,306.99
Special Order
Usually Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Experts for pre and post-sales support
Technical and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

Specialized training • U.S - based

Senior Specialist • 877-277-7147

Lifesafety Power FPO75/150-C8D8E6S-VZ01 75W power supply 6A/12V

$2,306.99

Overview

SKU: FPO75/150-C8D8E6S-VZ01
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Lifesafety Power FPO75/150-C8D8E6S-VZ01 Dual Output Power Supply with Relay Lock Control

Overview

The FPO75/150-C8D8E6S-VZ01 is a compact, dual-output power supply designed to provision access control systems, door locks, and security endpoints in mid-sized deployments. It delivers either 75W at 6A/12V or 75W at 3A/24V on the primary output, with a switchable 150W secondary stage (12A/12V or 6A/24V capacity), making it suitable for mixed-voltage security infrastructure. The unit supports up to 8 independent DC auxiliary outputs (6A/24V fused) and 8 supervised relay lock control outputs (3A per output, fused), each selectable for Bus 1 or Bus 2 operation—critical for fail-safe and fail-secure door control in multi-zone facilities.

Specifications & Deployment Benefit

The enclosure measures 30H × 23W × 6.5D inches and fits standard 19-inch rack or surface-mount installations. The 8-door output architecture with independent fusing on each relay output isolates fault domains—if one lock circuit fails, seven others remain operational. Selectable failsafe/failsecure modes per output enable mixed-mode deployments where some doors default to locked (secure) and others to unlocked (life safety). The dual-bus switching allows integration with primary and backup control panels without rewiring, reducing commissioning time on redundant systems.

Compatibility

This unit integrates with Lifesafety Power access control boards (SWH I8 / R8 series) and is sized for Verizon enclosure configurations. It supplies power infrastructure for door locks, magnetic strikes, and credential readers operating at 12V or 24V. The relay outputs support supervised lock control on systems requiring separate switching logic from power distribution.

Installation Notes

Each relay output is independently fused at 3A; auxiliary DC outputs at the supply are fused at 6A/24V. Verify load calculations for all connected devices before commissioning. The dual-bus architecture requires configuration at the control board level to assign outputs to Bus 1 or Bus 2 supervision.

Note: This unit is currently on backorder. Contact your distributor for delivery timeline.

Specifications
Form Factor: Rackmount/Surface-mount enclosure
Operating Temperature: Not specified in evidence
Approvals: FAI selectable (Fire Alarm Interface); specific certifications not confirmed in evidence
Input Voltage: AC 110-240V (inferred from dual-output design; confirm with manufacturer)
Output Voltage: 12V DC or 24V DC, selectable per stage
Max Current: Primary: 6A/12V or 3A/24V; Secondary: 12A/12V or 6A/24V
Number of Outputs: 8 DC auxiliary outputs + 8 relay lock control outputs (16 total supervised circuits)
Battery_Backup: Not specified in evidence
Enclosure_Dimensions: 30H × 23W × 6.5D inches (Verizon size)
Supervision: Dual-bus selectable per output; failsafe and failsecure modes supported
Q&A
Reviews
Have Questions? Ask an Expert.

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources