Lifesafety Power FPO150-2C82D8E4 16-Lock 16-Auxiliary Fused Output Module
Overview
The FPO150-2C82D8E4 is a fused power distribution module designed to control door locks and auxiliary devices from a single power supply. It provides 16 dedicated lock outputs and 16 auxiliary outputs, each individually fused at 3A. This isolates circuit failures — if one door strike shorts, the remaining 15 lock circuits stay live. Deploy this where you need distributed power management across multiple doors or zones without running separate power wiring to each device.
Compatibility
The FPO150-2C82D8E4 integrates with access control systems and power supplies that output raw DC voltage to modular distribution blocks. Confirm your power supply voltage (commonly 12VDC or 24VDC) matches the module's input specification before wiring. Compatible with standard electromagnetic door strikes, electric solenoid locks, magnetic locks, and relay-driven auxiliary loads (sirens, strobes, door sensors) rated within the 3A per-channel limit.
Installation Notes
Each of the 16 lock and 16 auxiliary channels is independently fused at 3A — verify that your door strike or auxiliary device does not exceed this rating to prevent nuisance fuse blown. The 3A fuse protects both the device and the power distribution module from overcurrent damage. Wire lock outputs to electromagnetic strikes or solenoids; wire auxiliary outputs to signaling devices or control relays. Ensure proper polarity (positive and negative) on all connections. Use appropriately gauged wire (typically 18 AWG for 3A circuits) to minimize voltage drop over cable runs.