APC by Schneider Electric
SKU: FS-AC-5006-B
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric FS-AC-5007-B is a rack blanking panel engineered specifically for the Hyperpod ecosystem, designed to fill unused rack unit space in 42U to 52U enclosures with a 750mm width profile. If you are managing airflow in a high-density datacenter or server room, open rack space is a liability — unblocked rack units allow hot exhaust air to recirculate back into equipment intakes, raising inlet temperatures and pushing cooling infrastructure harder than necessary. The FS-AC-5007-B closes those gaps, forcing cold aisle air to move through equipment rather than around it.
At 817mm tall and 2217mm in depth — dimensions that align with Hyperpod rack geometries — this panel is sized to cover the span from U42 through U52, providing continuous coverage across the lower rack section where blanking is most commonly overlooked during staged deployments. The black finish (product colour: black) integrates cleanly into standard APC rack enclosures without visual inconsistency.
The FS-AC-5007-B is designed as an accessory for APC's Hyperpod rack system. Confirm your specific Hyperpod enclosure model accepts this blanking panel before deployment — the 750mm width and 42–52U coverage range are the two critical fit parameters. This panel is not a universal blanking solution; it is a purpose-built Hyperpod component. Attempting to install it in a non-Hyperpod APC rack or a third-party enclosure of differing width or depth may result in a poor fit or inability to secure the panel correctly.
For environments running rack management accessories alongside APC power and cooling infrastructure, this blanking panel integrates into a broader APC by Schneider Electric rack ecosystem without requiring additional hardware or tools beyond what APC Hyperpod installations typically include. If you are sourcing other power and UPS components for the same enclosure, review APC's Hyperpod accessory compatibility list to ensure all panel, shelf, and power rail dimensions align.
Q: What rack width does the FS-AC-5007-B fit?
A: The FS-AC-5007-B is designed for 750mm wide rack enclosures, specifically within the APC Hyperpod ecosystem. It will not fit standard 600mm racks — confirm your enclosure width before ordering.
Q: What rack unit range does this blanking panel cover?
A: This panel is designed to cover the 42U to 52U zone of compatible Hyperpod enclosures, providing continuous blanking across that section of the rack.
Q: What certifications does the FS-AC-5007-B carry?
A: The FS-AC-5007-B is certified to cUL, UL, and CE standards, covering North American (US and Canada) and European safety compliance requirements.
Q: What is the warranty on the FS-AC-5007-B?
A: APC provides a 1-year manufacturer warranty on the FS-AC-5007-B.
Q: How heavy is the FS-AC-5007-B when packaged?
A: The packaged weight is 14 kg. Given the size and weight, a two-person installation is advisable, especially in a partially populated rack environment.
Q: Is the FS-AC-5007-B compatible with non-APC racks?
A: This panel is purpose-built for APC Hyperpod rack enclosures. Compatibility with non-APC or non-Hyperpod enclosures is not confirmed — use only in the Hyperpod system it was designed for.

The FS-AC-5007-B is one of those parts that gets overlooked in the BOM until someone measures a 6°C inlet temperature spike on the lower-shelf servers and traces it back to an unsealed 42–52U span. At 817mm in height and built specifically for 750mm Hyperpod enclosures, this panel fills a coverage gap that individual 1U fillers simply cannot address as efficiently — you would need 11 separate filler panels to match what this single piece does.
Technical Highlights:
Deployment Considerations:
The FS-AC-5007-B is the right call for Hyperpod-based builds where the 42–52U zone is intentionally left unpopulated during phased server deployment — seal it now rather than chasing airflow problems six months into production when the rack is full and access is harder.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price