Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FHC9N-12-3GAF
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 31% OFF

Panduit FHC9N-12-3GAF MPO-SC/APC 12-Fiber OS2 Cassette

Panduit FHC9N-12-3GAF HD Flex MPO-to-SC/APC Fiber Cassette The Panduit FHC9N-12-3GAF is a 12-fiber singlemode cassette engineered for high-density tru…

$960.12 $663.99 SAVE $296

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FHC9N-12-3GAF MPO-SC/APC 12-Fiber OS2 Cassette

$960.12
$663.99

Overview

SKU: FHC9N-12-3GAF
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FHC9N-12-3GAF HD Flex MPO-to-SC/APC Fiber Cassette

The Panduit FHC9N-12-3GAF is a 12-fiber singlemode cassette engineered for high-density trunk breakout in data centers, telecom hubs, and enterprise backbone installations. It transitions one MPO-12 male trunk interface to six duplex SC/APC connectors, delivering Method A modified (pair-reversed) polarity for compliance with TIA-568 structured cabling standards. Built on OS2 9-micron fiber with standard insertion loss, this cassette integrates into Panduit HD Flex enclosures and panels, enabling scalable 40G/100G trunk-to-10G patch architectures without field splicing or polarity guesswork.

Key Features

  • MPO-12 to 6× Duplex SC/APC Breakout: One trunk port expands to six duplex SC/APC patch connections, reducing panel footprint by 50% compared to individual simplex breakouts
  • OS2 Singlemode Fiber, 9-Micron Core: Rated for 10 km+ reach at 10 Gb/s and 2 km at 40 Gb/s, supporting long-haul backbone and campus fiber links with low chromatic dispersion
  • Method A Modified Polarity (Pair Reversed): Factory-terminated with TIA-568 Method A reversed-pair configuration, eliminating field polarity testing and ensuring plug-and-play compliance with structured cabling deployments
  • Standard Insertion Loss: ≤0.75 dB typical per mated pair, preserving optical power budgets for multi-span links and high-channel-count systems
  • SC/APC Angled Physical Contact: 8° ferrule polish reduces back-reflection to -60 dB, critical for analog video transport, coherent optics, and FTTx PON architectures where reflected light degrades signal integrity
  • HD Flex Ecosystem Compatibility: Drop-in fit for Panduit FAP™ and FMP™ panels, FHD adapter plates, and modular fiber enclosures, sharing common latch and retention hardware across the HD Flex family
  • Black Polycarbonate Housing: UL 94 V-0 flame-rated shell with integrated dust caps and color-coded boots for quick port identification during adds/moves/changes
  • Factory Tested & Serialized: Each cassette ships with insertion-loss test data and serialized label for asset tracking and warranty traceability in mission-critical installations

MPO-to-SC/APC cassettes solve the central challenge of modern fiber infrastructure: how to transition high-fiber-count trunk cables into individually manageable patch connections without consuming excessive rack space or introducing field-termination variability. The FHC9N-12-3GAF addresses this by concentrating 12 fibers—originating from a single MPO-12 trunk connector—into six duplex SC/APC ports within a cassette roughly the size of four stacked keystone jacks. This 6:1 port density advantage allows data center and telecom operators to deploy 144-fiber or 288-fiber MPO trunk cables between buildings or floors, then break out to traditional SC duplex patch cords at each equipment rack without dedicating an entire wall cabinet to interconnect hardware. The OS2 fiber specification ensures the cassette supports both legacy 1G/10G Ethernet links and emerging 40GBASE-LR4 / 100GBASE-LR4 applications, where four or ten wavelengths are multiplexed across a single fiber pair. The 9-micron core diameter and <0.4 dB/km attenuation at 1310 nm yield a conservative 10 km reach at 10 Gb/s, sufficient for campus backbone runs, metro-area dark fiber leases, and interconnects between colocation facilities. Method A modified polarity—also called "pair-reversed" or "inverse-key"—means Fiber 1 on the MPO trunk maps to Position 2 on the SC side, Fiber 2 to Position 1, and so on, alternating the transmit/receive pair sequence to match the TIA-568.3-D appendix for duplex connectivity. This factory-configured polarity eliminates the need for crossover patch cords or field re-pinning, a frequent source of link failures when installers mix Method A, B, and C cassettes in the same panel. Standard insertion loss (<0.75 dB per mated connector pair) preserves optical power budgets across multi-span links; in a typical 40GBASE-LR4 deployment with 2 km reach and 8.4 dB total loss budget, each cassette consumes only 1.5 dB (two mated pairs: MPO-to-cassette and cassette-to-SC patch), leaving 6.9 dB for fiber attenuation, splice losses, and aging margin. The SC/APC angled physical contact interface is essential for installations carrying analog CATV video, coherent 100G optics, or passive optical network (PON) signals, where even -40 dB of back-reflection can cause bit errors or analog beat noise; the 8° ferrule angle reflects light into the cladding rather than back toward the source, achieving -60 dB return loss and meeting ITU-T G.671 requirements for reflectance-sensitive systems.

Deployment context for the FHC9N-12-3GAF centers on rack-mount fiber distribution panels (FDPs) and wall-mount lightguide interconnect units (LIUs) serving as the breakout point between MPO trunk cables and SC duplex patch cords. A common architecture: 12-fiber or 24-fiber MPO trunk cables run as the building backbone (riser or plenum-rated), terminating in an equipment room or main distribution frame where multiple FHC9N-12-3GAF cassettes populate a 1U or 2U HD Flex panel. Each cassette's six SC/APC ports face forward, accessible for patching to switches, media converters, or DWDM mux/demux shelves, while the rear MPO-12 male connector mates with the MPO trunk cable's female plug. This "trunk-and-branch" topology reduces cable congestion in vertical pathways—one 12-fiber MPO cable replaces six duplex LC or SC cables—and simplifies adds/moves/changes by isolating patching activity to the front panel while leaving the backbone trunk undisturbed. Installers favor Method A modified polarity when the equipment-side transceivers follow the industry-standard transmit/receive pinout (Tx on Fiber 1, Rx on Fiber 2 for duplex links), as it allows straight-through SC patch cords without crossover adapters. The polycarbonate housing integrates into Panduit's FAP angled adapter panels and FMP flat modular panels via a snap-latch mechanism that requires no screws or adhesive; cassettes can be swapped in under 30 seconds for field upgrades or fault isolation. The black color coding distinguishes singlemode OS2 cassettes from multimode OM3/OM4 variants (typically aqua or lime green), reducing the risk of inserting a 9-micron singlemode patch cord into a 50-micron multimode port, which would result in >15 dB excess loss and link failure. Each cassette ships with protective dust caps on all SC adapters and the MPO port, critical for maintaining <0.75 dB insertion loss in dusty construction environments or long-term storage before installation; a single dust particle on an APC ferrule can increase loss by 0.3 dB and degrade return loss below specification. The 10-pack carton quantity aligns with typical 60-port (10-cassette) or 120-port (20-cassette) panel builds, minimizing packaging waste and simplifying inventory for staged rollouts across multiple floors or buildings.

The FHC9N-12-3GAF's Method A modified polarity and factory serialization differentiate it in environments where documentation and traceability are non-negotiable. Every cassette leaves Panduit's facility with insertion-loss test results for all six duplex pairs recorded on a serialized label, providing a baseline for acceptance testing and future troubleshooting; if a link fails commissioning, installers can compare field OTDR traces against the factory data to isolate whether the fault lies in the cassette, the trunk cable, or the patch cord. This serialized traceability also satisfies change-management protocols in healthcare, financial services, and government data centers, where every fiber path must map to a specific asset tag for audit and compliance purposes. The pair-reversed polarity ensures compatibility with TIA-568.3-D structured cabling systems and Panduit's own QuickNet™ pre-terminated solutions, where MPO trunk assemblies and cassettes are ordered as a matched set with guaranteed end-to-end polarity. For installations mixing vendor equipment—such as Cisco 40G QSFP+ transceivers (which expect Method B polarity) and Juniper 100G CFP modules (Method A)—the cassette's fixed Method A modified configuration provides a known reference point, allowing network engineers to select the correct MPO trunk cable type (straight-through or key-up/key-down) to achieve polarity alignment without field re-pinning. The SC/APC interface is the mandated connector type for Verizon FiOS, AT&T fiber-to-the-premises, and most PON deployments, making this cassette a direct fit for central office and outside plant applications where service providers transition from feeder cables to individual subscriber drops.

Specifications
Product Type: Fiber Optic Cassette
Brand: Panduit
MPN: FHC9N-12-3GAF
Sub-Brand: HD Flex
Fiber Type: OS2 Singlemode
Fiber Core Diameter: 9 micron
Number of Fibers: 12
Connector 1 Type: MPO-12 Male
Connector 2 Type: SC Duplex (6 ports)
Connector Polish: APC (Angled Physical Contact, 8°)
Polarity Method: Method A Modified (Pair Reversed)
Insertion Loss: ≤0.75 dB (standard)
Return Loss: ≥60 dB (APC)
Housing Material: Polycarbonate, UL 94 V-0
Housing Color: Black
Operating Temperature: -40°C to +75°C
Package Quantity: 1
Carton Quantity: 10
UPC: 061305670090
Compliance: TIA-568.3-D, IEC 61754-7 (MPO), IEC 61754-4 (SC)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources