Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric GVSUPS50KMHS Double-Conversion UPS

Overview

The APC by Schneider Electric GVSUPS50KMHS is a 50kVA double-conversion (online) uninterruptible power supply designed for critical IT infrastructure. It delivers clean, stable sine wave power with 400V output, ensuring sensitive equipment remains operational during power disturbances. This UPS is suitable for rack or tower deployments in data centers or network closets requiring robust, continuous power.

Compatibility

This UPS is designed for external battery configurations and operates with 400V 3-phase input and output. It supports an input voltage range of 340-460V and an input frequency of 40/70 Hz, making it compatible with standard industrial power grids. The 50/60 Hz output frequency is selectable to match local power requirements. It is intended for use with APC's Galaxy VS external battery systems.

Installation Notes

Requires a 3-phase power connection. Maximum input current is 90A. The unit has a heat dissipation of 5804 BTU/h, necessitating adequate ventilation or cooling in the installation environment. Noise level is rated at 68 dB, requiring consideration for placement in noise-sensitive areas.

Specifications Summary

  • Topology: Double-conversion (Online)
  • Output Power: 50 kVA / 50000 W
  • Output Waveform: Sine
  • Input Voltage Range: 340-460V
  • Output Voltage: 400V
  • Input/Output Phases: 3-Phase
  • Power Factor: 1
  • THD (Output): 5%
  • THD (Input): 3%
  • Noise Level: 68 dB
Specifications
UPS topology: Double-conversion (Online)
Output power capacity: 50 kVA
Output power: 50000 W
Waveform: Sine
Input operation voltage (min: 340 V
Input operation voltage (max: 460 V
Input frequency: 40/70 Hz
Output operation voltage (min: 400 V
Output frequency: 50/60 Hz
Maximum current: 90 A
Heat dissipation: 5804 BTU/h
Number of input phases: 3
Number of output phases: 3
Power factor: 1
Crest factor: 2.5:1
Output voltage Total Harmonic Distortion (THD: 5%
Input current Total Harmonic Distortion (THD: 3%
Noise level: 68 dB
Q&A
Reviews
Have Questions?

APC by Schneider Electric Galaxy vs UPS 50KW 400V for External Batteries - GVSUPS50KMHS

$46,200.00
$30,763.99

RELATED PRODUCTS

Save $16,007.01
APC by Schneider Electric Galaxy VS UPS 50KW 400V Scalable TO 150KW FOR External Batteries, Start-up 5X8
Add to Cart The item has been added

APC by Schneider Electric GVSUPS50K150HS

APC by Schneider Electric Galaxy vs UPS 50KW 400V Scalable to 150KW for External - GVSUPS50K150HS

50kW (50 kVA) three-phase online double-conversion UPS designed for data centers, large commercial facilities, and industrial environments where

    Usually Ships in 2-3 Weeks Free shipping over $499
    $47,915.00 $31,907.99 Save $16,007.01
    The item has been added Add to quote
    $47,915.00 $31,907.99 Save $16,007.01
    Save $16,007.01 Add to cart Add to quote
    Save $13,680.01
    APC by Schneider Electric Galaxy vs UPS 40KW 400V for External Batteries - GVSUP
    Add to Cart The item has been added

    APC by Schneider Electric GVSUPS40KMHS

    APC by Schneider Electric Galaxy vs UPS 40KW 400V for External Batteries - GVSUPS40KMHS

    40kVA, 400V double-conversion (online) UPS designed to deliver clean, stable, and uninterrupted power to critical IT infrastructure and sensitive

      Usually Ships in 2-3 Weeks Free shipping over $499
      $40,950.00 $27,269.99 Save $13,680.01
      The item has been added Add to quote
      $40,950.00 $27,269.99 Save $13,680.01
      Save $13,680.01 Add to cart Add to quote
      Save $22,750.01
      APC by Schneider Electric Galaxy vs UPS 120KW 400V for External Batteries - GVSU
      Add to Cart The item has been added

      APC by Schneider Electric GVSUPS120KMHS

      APC by Schneider Electric Galaxy vs UPS 120KW 400V for External Batteries - GVSUPS120KMHS

      120kW (120 kVA) of clean, reliable power using a double-conversion online topology

        Usually Ships in 2-3 Weeks Free shipping over $499
        $68,100.00 $45,349.99 Save $22,750.01
        The item has been added Add to quote
        $68,100.00 $45,349.99 Save $22,750.01
        Save $22,750.01 Add to cart Add to quote
        Save $18,590.01
        APC by Schneider Electric Galaxy vs UPS 80KW 400V for External Batteries - GVSUP
        Add to Cart The item has been added

        APC by Schneider Electric GVSUPS80KMHS

        APC by Schneider Electric Galaxy vs UPS 80KW 400V for External Batteries - GVSUPS80KMHS

        N 80 kVA / 80 kW double-conversion (Online) UPS designed to provide critical power protection for sensitive equipment

          Usually Ships in 2-3 Weeks Free shipping over $499
          $55,645.00 $37,054.99 Save $18,590.01
          The item has been added Add to quote
          $55,645.00 $37,054.99 Save $18,590.01
          Save $18,590.01 Add to cart Add to quote

          System Design, Deployment & Technical Support

          Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

          Fixed scope • Fixed price

          System Design Assistance

          • Get help validating product compatibility
          • Coverage requirements
          • Storage planning and deployment architecture before you buy.
          Request Design Help

          Deployment & Configuration Support

          • Access fixed-scope support for rollout planning
          • User setup guidance
          • Migration and system standardization across single-site or multi-site deployments
          View Support Services

          Guides, Tools & Calculators

          • PoE requirements
          • Storage retention
          • Camera selection and deployment methodology
          Open Technical Resources