Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric GVSUPS50KRGS 50kW 480V N+1 Modular UPS

Overview

The APC by Schneider Electric GVSUPS50KRGS is a 50 kVA / 50 kW three-phase uninterruptible power supply built around an N+1 redundant power module architecture, designed for data centers, industrial environments, and critical infrastructure sites where a single point of failure on the UPS itself is unacceptable. The 480V configuration targets North American large-load deployments — enterprise server rooms, network operations centers, and facility-level power protection — where stepping down from utility-grade 480V service avoids an extra transformer stage and reduces conversion losses before the load.

The Galaxy VS platform from APC by Schneider Electric is engineered for scalability: the external battery architecture means runtime is not fixed at purchase — you size the battery cabinet array to the runtime budget your site demands, then expand as load or retention requirements grow. This is a materially different procurement model than sealed internal-battery UPS units, where capacity is fixed at the factory.

Key Features

  • 50 kW / 50 kVA at Unity Power Factor: apparent and real power ratings are identical at 50 kW and 50 kVA, meaning the unit delivers its full nameplate wattage to resistive and modern switch-mode power supply loads without derating — relevant when powering high-density server racks where actual draw closely tracks real power.
  • N+1 Power Module Redundancy: the modular design includes one more power module than the minimum required to carry the load. If a single module fails, the remaining modules absorb the load without interruption — critical for sites that cannot tolerate a maintenance window to swap a UPS unit.
  • 480V Input/Output: native 480V three-phase operation connects directly to large-facility power distribution without an intermediate step-up transformer, reducing infrastructure cost and improving overall system efficiency on high-load installations.
  • Lithium-Ion Battery Technology: Li-Ion chemistry offers a significantly longer service life and a smaller footprint compared to traditional valve-regulated lead-acid (VRLA) alternatives. Fewer battery replacements over the system lifecycle reduce both maintenance labor and disposal costs — a concrete total-cost-of-ownership advantage for long-horizon data center planning. Pairs with compatible UPS battery cabinets sized to your runtime requirement.
  • Pure Sine Wave Output: the GVSUPS50KRGS produces a true sine waveform rather than a stepped approximation. Sensitive loads — variable-frequency drives, medical equipment, precision instrumentation — require sine output; a simulated or stepped-sine UPS can cause these devices to fault or operate outside specification under generator or battery power.
  • External Battery Architecture: batteries are housed in separate external cabinets rather than inside the UPS chassis. This separates the power electronics service cycle from the battery replacement cycle, allows runtime to be extended without replacing the main unit, and keeps the UPS footprint predictable as capacity scales.
  • Startup 5 Service Included: the SKU includes Schneider Electric's Startup 5 commissioning service — a factory-trained technician performs initial installation verification, system configuration, and documentation. For a 50 kW critical power installation, this eliminates the guesswork of self-commissioning and establishes a documented baseline for future service events.

Integration and Compatibility

The Galaxy VS platform is designed to integrate with Schneider Electric's EcoStruxure IT architecture for remote monitoring, predictive analytics, and fleet-level power management. At 480V, the unit is sized for use in conjunction with matching power distribution units and external battery enclosures from the Galaxy VS accessory line. Consult your facility's single-line diagram before specifying input breaker sizing and cable runs — a 50 kW load at 480V three-phase draws significant current and the installation requires licensed electrical work in most jurisdictions.

For sites evaluating total uninterruptible power supply architecture, note that the N+1 module configuration in the GVSUPS50KRGS is distinct from system-level N+1 redundancy (two independent UPS units on an ATS). Evaluate which tier of redundancy your uptime SLA requires before specifying.

Frequently Asked Questions

Q: What is the difference between the GVSUPS50KRGS and the GVSUPS50KRFS?

A: Both are Galaxy VS 50 kW N+1 modular UPS units with external battery support and Startup 5 service. The GVSUPS50KRGS operates at 480V, targeting large North American facilities fed from 480V three-phase service. The GVSUPS50KRFS operates at 208V, suited to environments where the distribution voltage is 208V three-phase. Confirm your facility's service voltage before ordering — these are not interchangeable.

Q: Does the GVSUPS50KRGS include batteries?

A: No. The SKU is configured for external batteries — battery cabinets are ordered separately. This architecture lets you size runtime to your specific load and budget independently of the UPS power electronics.

Q: What battery chemistry does the GVSUPS50KRGS use?

A: Lithium-ion (Li-Ion). Compared to VRLA lead-acid, Li-Ion typically offers a longer service life and reduced weight per unit of energy stored, which can simplify floor loading calculations in raised-floor data centers.

Q: Is the GVSUPS50KRGS suitable for generator-backed installations?

A: The pure sine wave output makes it compatible with generator-backed power environments where sensitive loads require clean waveform during generator run mode. Verify generator sizing accounts for UPS input current requirements including battery recharge load.

Q: What does the Startup 5 service included in this SKU cover?

A: Startup 5 is Schneider Electric's factory-supervised commissioning service. It covers initial installation verification, system startup, and configuration by a Schneider Electric field technician, and produces a documented commissioning record — important for warranty baseline and service history.

Eden Phillips
Eden Phillips

The GVSUPS50KRGS sits in a specific and deliberate spot in the Galaxy VS lineup: 50 kW real power at 480V with N+1 module redundancy and an external battery architecture. That combination is not accidental — it is purpose-built for North American large-facility deployments where the utility feed is 480V three-phase, the load density is high enough to justify modular redundancy at the UPS level, and the site operator wants to decouple battery replacement cycles from power electronics service intervals.

Technical Highlights:

  • Unity Power Factor (50 kW = 50 kVA): the equal real and apparent power ratings mean there is no derating penalty on modern server and networking loads — you get the full 50 kW to the load, not a reduced figure after accounting for power factor correction.
  • Lithium-Ion Chemistry: Li-Ion battery technology in the external cabinet configuration reduces long-term replacement frequency compared to VRLA, which typically requires replacement every 3–5 years. Over a 10–15 year facility lifecycle this translates to meaningfully fewer maintenance events and lower disposal logistics.
  • Pure Sine Wave Output: at 50 kW serving mixed critical loads — servers, storage arrays, network gear, possibly precision cooling — sine wave output is non-negotiable. Stepped or modified sine alternatives risk fault conditions on variable-frequency drives and active PFC power supplies under battery or generator transfer.

Deployment Considerations:

  • The 480V input requires licensed three-phase electrical work and correctly sized upstream overcurrent protection — factor this into project timeline and budget; it is not a self-install unit.
  • Batteries are external and ordered separately: confirm battery cabinet compatibility, floor load ratings, and runtime calculations before finalizing the bill of materials. The GVSUPS50KRGS chassis alone does not provide any runtime without paired external battery cabinets.

This unit is the right specification for an enterprise data center or network operations center drawing from a 480V distribution panel, where the design brief requires modular UPS redundancy and a Li-Ion battery strategy — not a general-purpose branch-circuit UPS replacement.

Specifications
Apparent Power: 50 kVA
Real Power: 50000 W
Waveform: Sine
Battery Type: Lithium-Ion (Li-Ion)
Color: White
freight: 602.52
Q&A
Reviews
Have Questions?

APC by Schneider Electric GVSUPS50KRGS 50KW UPS

$59,700.00
$39,755.99

RELATED PRODUCTS

Save $20,171.01
APC by Schneider Electric Galaxy vs UPS 50KW 480V with N+1 Power Module for 5 - GVSUPS50KR0B5GS
Add to Cart The item has been added

APC by Schneider Electric GVSUPS50KR0B5GS

APC by Schneider Electric GVSUPS50KR0B5GS 50KW UPS

N N+1 power module designed to provide critical backup power for high-demand applications, specifically supporting 50KW loads at 480V

    Usually Ships in 2-3 Weeks Free shipping over $499
    $60,380.00 $40,208.99 Save $20,171.01
    The item has been added Add to quote
    $60,380.00 $40,208.99 Save $20,171.01
    Save $20,171.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources