Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit XGL64812B FlexFusion 48RU Server Rack Cabinet

The Panduit XGL64812B FlexFusion rack delivers the thermal management, access flexibility, and structural capacity integrators need for high-density datacenter and surveillance NVR deployments. This 48RU enclosure combines 600mm width with 1070mm depth—accommodating deep servers, UPS units, and enterprise NVRs while maintaining front-to-back airflow through fully perforated doors. Split rear doors, tool-free side panels, and included PDU mounting brackets streamline installation and maintenance in both new builds and retrofit projects where every minute of uptime counts.

Key Features

  • 48RU Capacity: Full-height vertical space supports mixed equipment loads—NVRs, switches, patch panels, UPS, and rackmount servers in a single enclosure
  • 1070mm Depth: Accommodates deep enterprise servers, extended UPS modules, and cable management arms without rear-door interference
  • Perforated Front & Split Rear Doors: Maximize airflow for heat-generating equipment while split rear doors allow independent left/right access without blocking adjacent racks
  • Powder-Coated Steel Construction: Durable black finish resists scratches and corrosion; welded frame supports up to 3,000 lbs static load
  • Included Mounting Hardware: Ships with adjustable equipment rails, cage nuts, PDU brackets, and locking casters—everything needed for immediate deployment
  • Tool-Free Side Panels: Quick-release side walls enable fast access for cross-connects and adds without disturbing mounted equipment
  • PDU Mounting Brackets: Pre-installed vertical PDU channels accept both 0U and 1U power distribution units without consuming rack space
  • Seismic & NEBS Compliant: Meets Zone 4 seismic and Network Equipment Building System standards for mission-critical telecom and datacenter environments

The XGL64812B addresses three persistent challenges in enterprise AV and security installations: thermal bottlenecks, rear-access constraints, and integration of non-standard equipment. The 600mm width accepts standard 19" EIA-310 rackmount gear while the 1070mm depth accommodates deep Dell PowerEdge servers, HPE ProLiant chassis, and extended-depth UPS units like APC SmartUPS 3000 without rear overhang. Fully perforated front and rear doors provide 68% open area—significantly higher than solid or lightly vented alternatives—allowing unimpeded front-to-back airflow even when populated with high-wattage NVRs running 64+ camera streams. Split rear doors eliminate the access headaches common in back-to-back row layouts: the left door swings independently of the right, so you can service power feeds or fiber trunks on one side without blocking the neighboring rack's service corridor. For integrators running structured cabling or troubleshooting cross-connects, tool-free side panels lift off in seconds without requiring a screwdriver or disrupting mounted equipment.

Thermal management often determines whether a surveillance or IT deployment succeeds long-term. The XGL64812B's perforated door design sustains positive front-to-back airflow at equipment inlet temperatures up to 77°F (25°C) when paired with in-row cooling or raised-floor HVAC. In typical applications—enterprise NVRs drawing 800–1200W, core switches at 400W, and UPS units regenerating heat—the open-area doors prevent recirculation and exhaust stagnation that cause thermal shutdowns in solid-door enclosures. The included vertical PDU brackets accept 0U models like APC AP7xxx or Panduit CMBMRS series, placing outlets directly behind equipment while keeping power distribution outside the airflow path. Adjustable equipment rails ship pre-mounted with cage nuts and accommodate both square-hole and threaded mounting, so you're not stuck retrofitting rails mid-install. Locking casters allow repositioning during initial setup, then lock solid for permanent installation—critical in raised-floor datacenters where vibration from neighboring equipment can cause gradual drift.

Build quality separates specification-compliant racks from enclosures that survive 10+ years of adds, moves, and changes. The XGL64812B uses 16-gauge cold-rolled steel for the frame and 18-gauge for doors and panels, delivering a 3,000 lb static load rating and 2,200 lb rolling capacity—sufficient for fully populated configurations with redundant UPS, dense switch fabrics, and archive-grade storage arrays. Powder-coat finish is applied after welding and forming, creating a uniform black surface that resists chipping during equipment installation and won't flake when cage nuts are torqued. The split rear door design uses a vertical center mullion with independent hinges, so each door supports its own weight without sagging over time—a common failure mode in single-piece rear doors on lower-cost racks. For mission-critical deployments, the XGL series meets NEBS (Network Equipment Building System) Level 3 requirements including GR-63-CORE seismic Zone 4 compliance, making it suitable for telecom central offices and financial datacenter Tier III/IV builds where equipment must remain operational during seismic events.

FlexFusion racks are engineered for mixed-use environments where surveillance, access control, and IT infrastructure share a common enclosure. In typical integrator deployments, the lower 24RU might house an i-PRO X-series NVR with dual power supplies, a Cisco Catalyst 9300 PoE++ switch feeding IP cameras, and a UPS providing 15-minute runtime, while the upper 24RU supports patch panels, fiber enclosures, and a 1U rackmount workstation for on-site monitoring. The 1070mm depth ensures deep servers—like a Dell R750 with cable management arms extended—fit without rear-door contact, while front-to-back cable routing channels keep Cat6 and fiber separated from power feeds to minimize EMI. Split rear doors mean you can replace a failed UPS battery module by opening just the right door, without exposing sensitive fiber trunks on the left side or blocking access to an adjacent rack in a back-to-back row. The included PDU brackets eliminate the need for separate vertical channel kits, saving both cost and lead time on projects with tight schedules.

The XGL64812B ships as a complete assembly with adjustable square-hole equipment rails, 50 cage nuts and screws, a set of four locking/swivel casters rated for 550 lbs each, and vertical PDU mounting channels on both sides. The perforated front door includes a keyed lock with two keys; split rear doors each have independent locks. Installation requires a minimum 24.5" (622mm) width clearance and 45" (1143mm) depth clearance including door swing. For seismic installations, Panduit offers separately-sold floor anchor kits and overhead bracing brackets. The rack is compatible with Panduit Net-Access and PanZone cable management accessories, as well as universal 19" rackmount equipment following EIA-310-D spacing. Typical applications include enterprise server consolidation, high-density NVR and storage deployments, core network aggregation, and hybrid cloud edge infrastructure where compute, storage, and networking coexist in a single physical footprint.

  • Rack Units: 48RU (83.25" / 2115mm usable height)
  • External Dimensions: 90.1"H x 23.6"W x 42.1"D (2289 x 600 x 1070 mm)
  • Internal Usable Width: 19" (482.6mm) EIA-310-D compliant
  • Internal Usable Depth: 37.4" (950mm) front rail to rear rail adjustable
  • Construction Material: Cold-rolled steel, 16-gauge frame, 18-gauge doors/panels
  • Finish: Black powder coat, textured
  • Load Capacity: 3,000 lbs static, 2,200 lbs rolling
  • Door Perforation: 68% open area, 0.25" diameter holes
  • Front Door: Single hinged, reversible, keyed lock, perforated
  • Rear Doors: Split (left/right independent), reversible hinges, keyed locks, perforated
  • Side Panels: Removable, tool-free quick release
  • Equipment Rails: Adjustable depth, square holes, includes 50 cage nuts
  • PDU Mounting: Vertical channels both sides, 0U and 1U compatible
  • Casters: Four included, locking/swivel, 550 lbs capacity each
  • Compliance: EIA-310-D, NEBS GR-63-CORE Zone 4, RoHS
  • Shipping Weight: Approx. 485 lbs (220 kg)
  • Country of Origin: Mexico (Panduit manufacturing)
Specifications
MPN: XGL64812B
Product Line: FlexFusion
Rack Units: 48RU
Overall Height: 90.1 in (2289 mm)
Overall Width: 23.6 in (600 mm)
Overall Depth: 42.1 in (1070 mm)
Usable Internal Width: 19 in (482.6 mm)
Usable Internal Depth: 37.4 in (950 mm) adjustable
Construction Material: Cold-rolled steel
Frame Gauge: 16-gauge
Door and Panel Gauge: 18-gauge
Finish: Powder-coated
Color: Black
Static Load Capacity: 3,000 lbs
Rolling Load Capacity: 2,200 lbs
Front Door: Perforated, hinged, reversible, keyed lock
Rear Doors: Split perforated, independent hinges, keyed locks
Door Perforation: 68% open area
Side Panels: Tool-free removable
Equipment Rails: Adjustable square-hole with cage nuts
Included Cage Nuts: 50
PDU Mounting: Vertical brackets both sides (0U/1U compatible)
Casters: Four locking/swivel, 550 lbs each
Compliance: EIA-310-D, NEBS GR-63-CORE Zone 4, RoHS
UPC: 061305685957
Package Quantity: 1
Shipping Weight: Approx. 485 lbs (220 kg)
Country of Origin: Mexico
Type: Rack Cabinet
Sub Brand: FlexFusion™
Material: Stahl
Height In: 90.1
Height Mm: 2289
Width In: 23.6
Width Mm: 600
Carton Qty: 0
Package Qty: 1
Upc: 61305685957
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

Panduit XGL64812B 48RU FlexFusion Rack Cabinet

$5,817.23
$3,775.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources