Overview
DMP P2S-001 High Security Single Zone Magnetic Sensor
DMP P2S-001 High Security Single Zone Magnetic Sensor Overview The DMP P2S-001 is a single zone magnetic sensor designed for professional intrusion d…
DMP P2S-001 High Security Single Zone Magnetic Sensor
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
DMP P2S-001 High Security Single Zone Magnetic Sensor
Overview
The DMP P2S-001 is a single zone magnetic sensor designed for professional intrusion detection installations requiring reliable door and window monitoring. This accessory integrates into multi-zone security systems and supports HID credential-based access control workflows, making it suitable for facilities where door contact monitoring must coordinate with credential verification and system logging.
Key Features
- Single Zone Magnetic Detection: Dedicated zone reporting for individual door or window monitoring
- HID Credential Integration: Compatible with HID-based access control systems for unified security operations
- Intrusion/Contact Cable Category: Engineered for reliable signal transmission in intrusion detection circuits
- Professional-Grade Sensor: Magnetic switch technology for consistent contact status reporting
- Accessory Form Factor: Compact design supports retrofit and new-build installations
- Multi-Zone System Compatibility: Works within larger security architectures requiring zone-based monitoring
Integration & Compatibility
The P2S-001 magnetic sensor is classified as an intrusion/contact reader type accessory, designed to interface with security control panels that support HID credentials. This architecture allows integrators to deploy the sensor in environments where door contact monitoring must be logged and correlated with cardholder access events. The sensor's single zone design simplifies wiring and zone assignment in multi-door facilities, reducing configuration complexity while maintaining clear event reporting for audit and compliance purposes.
When deployed in access control systems, the P2S-001 provides real-time door contact status, enabling security teams to identify forced entries, prop-open conditions, and unauthorized access attempts. The sensor integrates seamlessly into existing intrusion detection infrastructure, supporting both hardwired and networked control panel architectures depending on system topology.
Typical Applications
The DMP P2S-001 is well-suited for office buildings, data centers, healthcare facilities, and secure storage environments where individual door monitoring is required. Security integrators commonly deploy this sensor in conjunction with card readers and access controllers to enforce dual-layer authentication—requiring both valid credentials and proper door handling to prevent tailgating and unauthorized facility access.
Single zone magnetic sensors like the P2S-001 are essential for compliance with physical security standards in regulated industries. When combined with centralized logging, these sensors create audit trails that document all door interactions, supporting investigations, forensic analysis, and regulatory reporting requirements.

From a systems design perspective, the DMP P2S-001 represents a straightforward but critical component in professional intrusion detection installations. During recent integration planning, I evaluated this single zone magnetic sensor in a multi-tenant office retrofit where door contact monitoring needed to align with existing HID credential workflows. The P2S-001's dedicated zone assignment and HID compatibility made it a practical choice for minimizing panel configuration overhead while maintaining granular event logging.
Technical Highlights:
- Single Zone Reporting: Isolates each door contact to its own zone, eliminating cross-door false positives and simplifying troubleshooting
- HID Credential Compatibility: Allows door contact events to be logged and correlated with access card swipes, creating comprehensive entry records
- Magnetic Switch Technology: Proven reliability in high-traffic doors with minimal maintenance
Deployment Considerations:
- Verify that your control panel's zone architecture supports the number of magnetic sensors required; single zone sensors like the P2S-001 require dedicated inputs
- Plan wiring runs carefully in retrofit scenarios—magnetic sensors typically require runs to the nearest control panel or expander module
- Coordinate sensor placement with card reader mounting to avoid RF interference and ensure that access events can be timestamped alongside contact events
- Document zone assignments clearly in your security system backup, especially in multi-door facilities, to accelerate incident response
The P2S-001 is a dependable sensor for facilities that need straightforward, zone-based door monitoring integrated into HID-based access control. It's not a feature-rich device, but it performs its core function reliably and integrates well into professional-grade security architectures.
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology