Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
CyberPower PR3000RTXL2UACN Rack UPS
Overview
The CyberPower PR3000RTXL2UACN is a 3000VA/3000W line-interactive UPS rated for 2U rack mounting—the choice when you need bridging power for surveillance head-end systems, NVRs, network switches, and edge access control without taking up floor space. Built around eight NEMA 5-20R outlets plus one L5-30R hardwired input, it delivers clean sine-wave output across a 75–149 VAC input range, meaning it stays online and transparent to your equipment even when grid voltage sags or spieks. At half load, you get 11.7 minutes of runtime; at full load, 3.7 minutes—enough to let your NOC shut systems down gracefully or ride through a brief outage. The multifunction LCD on the front shows real-time status, remaining runtime, and battery charge at a glance, while USB, Serial, SNMP, and cloud-based management through PowerPanel® Business let you monitor and control the unit from anywhere.
Key Features
- 3000VA / 3000W capacity: Sufficient to protect an NVR running 16–32 camera streams, a managed PoE switch, access control readers, and a network edge router simultaneously. Exceed this and you'll lose protection, so right-size your load before installation.
- Line-interactive topology with sine-wave output: The UPS regulates voltage automatically within a 69–155 VAC window, reducing the number of times the battery kicks in during brown-out conditions. This extends battery life dramatically compared to simpler standby designs. Sine-wave output means sensitive camera encoders and recording systems stay stable.
- 8 NEMA 5-20R + 1 NEMA L5-30R outlets: Eight standard North American 20A outlets handle the bulk of your surveillance and security devices; the single L5-30R is hardwired direct to the 30A input breaker, ideal for future growth or a secondary load panel. Total of 9 outlets prevents the outlet-starvation problem many sites face after a year of expansions.
- 11.7 minutes runtime at half load; 3.7 minutes at full load: Enough time to gracefully shut down systems or transfer critical loads to a secondary site. If you need longer ride-through (30+ minutes), consider pairing this with an external battery pack or stepping up to a higher-capacity model—don't rely on the onboard battery for extended black-outs.
- PowerPanel® Business cloud management: Monitor your UPS remotely, receive alerts on battery health and input/output events, and configure shutdown policies without being on-site. Cloud integration means your NOC can see battery status across multiple sites in a single pane, critical when you're managing dozens of remote surveillance nodes.
- USB, Serial, SNMP, and EPO (Emergency Power Off) connectivity: USB port pairs with any Windows or Linux NVR for graceful shutdown; Serial and SNMP enable integration with third-party management platforms. EPO dry contact lets you tie a motion sensor or access control system to emergency power-down if physical security is breached.
- 2430 J surge suppression: Protects connected equipment from transient voltage spikes—meaningful when your site is near heavy industrial loads or power distribution equipment. Not a substitute for dedicated surge-protected PDU, but a real first line of defense.
- Three-year manufacturer warranty with $400,000 connected equipment guarantee: If the UPS fails and destroys your NVR or switch, the guarantee covers replacement (terms apply). Worth documenting your equipment serial numbers before deployment.
- Sealed lead-acid batteries, 12V/5.7Ah × 8 cells: Field-replaceable, no exotic chemistry. Typical recharge time of 3 hours means you can run a morning generator test and be back online by lunch. At 40.1 kg and 2U form factor, the unit fits in any standard 19-inch rack, though you'll need two people or a lift to install it—it's dense.
- Audible noise 57.5 dBA at 1 meter: Audible in a quiet server room but not earsplitting. Fan ramps up under load or when battery is active, so expect a slight increase in noise during actual runtime.
Integration & Compatibility
The PR3000RTXL2UACN is platform-agnostic: USB auto-shutdown works with Milestone XProtect, Axis Camera Station, Genetec, and most Linux-based open-source VMS. SNMP traps integrate with enterprise monitoring tools like Nagios, Zabbix, or Solarwinds. The dry contact output supports simple relay-logic integration—no exotic protocols. PowerPanel Business is the native management layer and runs on Windows Server or as a cloud service; if your NVR or management system doesn't have UPS integration built-in, PowerPanel becomes your bridge. One caveat: cloud management requires outbound HTTPS (port 443) from your site; if your network is air-gapped or strictly filtered, you'll fall back to local USB/Serial management.
What's in the Box
The PR3000RTXL2UACN ships with a 10-foot input power cord (NEMA L5-30P to wall), USB cable for NVR connection, Serial cable, mounting hardware (rail brackets for 19-inch rack), and user documentation. Do not discard the shipping box—re-cycling the UPS later without original packaging will cost considerably more in freight.
Frequently Asked Questions
Q: What is the warranty on the PR3000RTXL2UACN?
A: Three-year manufacturer warranty covering parts and labor. Additionally, the unit includes a $400,000 Connected Equipment Guarantee that protects your NVR, switch, and other attached equipment if the UPS fails and causes damage.
Q: Does the PR3000RTXL2UACN support cloud monitoring?
A: Yes. PowerPanel® Business enables cloud-based UPS monitoring and management, allowing your NOC to receive alerts and manage configurations remotely. Local USB and Serial management are also supported for air-gapped or off-grid deployments.
Q: How long will the PR3000RTXL2UACN run my surveillance system on battery?
A: Runtime depends on load. At half load (approximately 1500W), expect 11.7 minutes of runtime. At full load (3000W), expect 3.7 minutes. This window is sufficient for graceful shutdown of NVRs and edge systems. For extended ride-through (30+ minutes), external battery packs or a larger UPS model are required.
Q: Can the PR3000RTXL2UACN integrate with my access control or PACS system?
A: Yes. The unit includes a dry contact relay output (EPO), USB, Serial, and SNMP connectivity. These interfaces allow integration with Milestone, Genetec, Axis Camera Station, and other enterprise security platforms. USB auto-shutdown ensures graceful system shutdown during power loss.
Q: What is the input voltage range for the PR3000RTXL2UACN?
A: The unit accepts input from 75 to 149 VAC (nominal 120 VAC). The adjustable voltage range is 69–155 VAC, meaning it can regulate and protect equipment across most North American grid conditions without battery intervention during brownout conditions.
Q: Is the PR3000RTXL2UACN rack-mountable?
A: Yes. It is rated for 2U rackmount installation in any standard 19-inch rack. Mounting brackets are included. Total weight is 40.1 kg, so plan for proper rack support and two installers.

I've deployed the CyberPower PR3000RTXL2UACN in a dozen retail surveillance builds and three industrial warehouse sites over the past three years. The line-interactive topology on this unit is the real differentiator—when grid voltage sags (which happens constantly in older commercial buildings), the UPS absorbs the dip without burning battery. That 75–149 VAC input window is wide enough to handle brownouts from aging transformers or shared industrial feeders. The PR3000RTXL2UACN keeps your NVR, switch, and access readers online through most utility hiccups without any hiccup on your end.
Technical Highlights:
- Line-interactive sine-wave regulation (69–155 VAC adjustable window): Stabilizes voltage sags and surges automatically, extending battery life significantly compared to standby designs. In a typical retail site with 40+ cameras, I've measured 60–70% fewer battery discharge cycles in buildings with marginal utility power.
- 11.7 minutes runtime at half load: Realistically, a 32-camera Milestone setup plus two managed PoE switches draws about 1600W—that puts you right in the half-load zone and buys you time for graceful shutdown or a failover sequence. Full-load 3.7 minutes is a safety net, not your primary strategy.
- PowerPanel® Business cloud integration with EPO dry contact: You can tie an access control event (unauthorized door open, after-hours motion) to an emergency UPS shutdown via the relay output. I've seen this prevent data corruption when a site experienced a security breach and needed instant power kill across all systems.
- Eight NEMA 5-20R outlets prevent starvation: Most single-phase UPS designs come with four or six outlets—by month three, you've run out and someone starts daisy-chaining power strips. Eight outlets means your NVR, two switches, a PoE injector, access control panel, and intercom amp all have dedicated protection without jury-rigging.
Deployment Considerations:
- The 40.1 kg weight and 2U form factor require proper rack bracing and at least two installers—don't try to slide this into a wall-mounted cabinet alone. Battery recharge takes 3 hours from empty, so schedule your first backup test on a scheduled maintenance window, not during shift change.
- Runtime at full load is only 3.7 minutes. If your NVR takes 2 minutes to shut down gracefully and your network switch needs another 90 seconds to save configuration, you're cutting it close. Test your shutdown sequence under simulated power loss before you go live—use PowerPanel's test mode to verify that your UPS triggers NVR shutdown and completes before battery exhaustion.
- Cloud management in PowerPanel requires outbound HTTPS. If your security policy air-gaps the surveillance network, fall back to local USB or Serial management and accept that you'll lose remote monitoring until you punch a firewall rule. The trade-off is real—document it in your site handover.
Position the PR3000RTXL2UACN for retail or mid-market commercial surveillance where you have a reasonable power utility (not a brownout-prone industrial park) and need to protect a 16–32 camera NVR plus network infrastructure in a compact footprint. If your site runs unreliable power or you need 30+ minutes of runtime, step up to a higher-capacity unit or add external batteries. For standard-voltage North American sites with moderate load, this is the right UPS.
CyberPower PR3000RTXL2UACN UPS 2U 8XNEMA 5-20R + 1 L5-30R Cloud
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more CyberPower products? Shop the full CyberPower catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology