Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv FSC3N003 is a 30-amp, three-phase power distribution unit built for high-density data center racks and commercial equipment rooms where stable, flexible power delivery is non-negotiable. With a NEMA L21-30P input plug and support for both 120V and 208V output, this unit handles mixed-voltage rack environments without requiring separate branch circuits for each voltage tier. If you're running a cabinet that mixes 120V networking gear with 208V servers or storage, the FSC3N003 eliminates the need for separate PDUs for each voltage level.
Vertiv's power infrastructure line is engineered for enterprise and mission-critical environments — the FSC3N003 fits directly into that lineage, designed to sit inside standard equipment racks where uptime and load management matter.
The FSC3N003 is designed to integrate with standard data center power infrastructure. The L21-30P input connects directly to 30A, 3-phase WYE branch circuits — the type commonly provisioned off a 3-phase PDU or power panel in commercial data centers and server rooms. Confirm your panel or upstream PDU provides a NEMA L21-30P receptacle before ordering; this is the standard for this amperage/voltage combination, but some facilities use NEMA L15-30 (250V, 3-phase WYE, 30A) which is not interchangeable.
The universal connector output format of the FSC3N003 supports flexible receptacle configurations — verify your specific outlet configuration against your equipment power cords during pre-deployment planning. For power distribution units and associated rack power infrastructure, matching input plug type and circuit breaker rating at the panel is the most common installation error. Review your Vertiv power infrastructure options to ensure the full power chain — from panel to PDU to device — is correctly specified.
For installations pairing this PDU with network security hardware, rack-mounted network video recorders, or edge compute nodes, confirm total rack load stays within 80% of the 30A circuit capacity under continuous operation. For environments also requiring structured cabling and PoE switches, plan branch circuit allocation to keep the PDU load balanced across phases. Consult your facility's electrical drawings for available panel capacity before provisioning the L21-30P circuit.
Q: What input plug type does the FSC3N003 use?
A: The FSC3N003 uses a NEMA L21-30P twist-lock input plug, which is the standard for 30A, 3-phase, 120/208V WYE circuits. Ensure your panel or upstream PDU provides a matching L21-30P receptacle before installation.
Q: What output voltages does the FSC3N003 support?
A: The FSC3N003 supports both 120V and 208V output, making it suitable for mixed-voltage rack environments where some equipment requires 120V and other devices require 208V efficiency-optimized power.
Q: What is the maximum continuous load for the FSC3N003?
A: The FSC3N003 is rated at 30A capacity. Per NEC best practice, continuous loads should not exceed 80% of circuit rating — plan for no more than 24A of continuous draw to stay within code-compliant operating parameters.
Q: Can the FSC3N003 be used with international 50Hz power infrastructure?
A: Yes. The FSC3N003 supports both 50Hz and 60Hz input frequency, making it compatible with international facilities or generator power that may operate at 50Hz.
Q: What is the operating temperature rating for the FSC3N003?
A: The FSC3N003 is rated to operate at up to 60°C, which exceeds the ASHRAE A2 envelope. This allows deployment in edge locations, secondary equipment rooms, or hot-aisle environments without thermal derating.
Q: Is the L21-30P plug interchangeable with NEMA L15-30?
A: No. The NEMA L21-30P (120/208V WYE, 3-phase, 30A) is not interchangeable with the NEMA L15-30 (250V, 3-phase, 30A). Verify your facility's panel receptacle type before installation to avoid a mismatch.

The FSC3N003's 120/208V WYE dual-voltage output is the spec I key in on first when evaluating PDUs for mixed-vendor racks. Most data center buildouts I see involve exactly this scenario — legacy 120V network and security hardware alongside 208V compute — and having one 30A PDU handle both voltages on a single L21-30P circuit keeps the panel design clean and reduces the number of discrete branch circuits you need to provision.
Technical Highlights:
Deployment Considerations:
The FSC3N003 is the right call for a mixed-voltage security operations center rack — specifically where you're combining 120V surveillance recording appliances, PoE switch stacks, and 208V-native compute nodes under a single 30A branch circuit. That's the deployment scenario this unit is built for.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price