Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric 0M-5886-045 50A 250V 3P-4W 45 ft Power Cordset

Overview

The APC by Schneider Electric 0M-5886-045 is a heavy-duty 3-phase power cordset rated at 50A and 250V, designed to bridge high-draw electrical equipment to facility power distribution in commercial and industrial installations. At 45 feet, this cord provides meaningful reach across server rooms, data halls, and equipment bays without requiring custom cable runs — a practical detail when you're working around fixed panel locations and floor-mounted PDUs or UPS units.

The 3-pole, 4-wire (3P-4W) configuration is standard for balanced 3-phase loads at this amperage tier, supporting neutral and ground conductors alongside the three line conductors. This matters in environments where neutral is required by the load — not all 3-phase cordsets carry neutral, so confirming 4-wire construction before ordering is worth the extra step. The 0M-5886-045 (often searched as 0M 5886 045) is built to APC by Schneider Electric's commercial-grade standards, consistent with the broader APC by Schneider Electric power distribution catalog.

Key Features

  • 50A / 250V Rating: Supports high-density power distribution loads — appropriate for large UPS systems, high-draw PDUs, or industrial electrical feeds where standard 20A or 30A cords fall short.
  • 3-Pole, 4-Wire Construction: The 4-wire design includes a neutral conductor, required by many commercial UPS and PDU configurations. A 3-wire-only cord at this amperage tier would be incompatible with neutral-referenced loads, so this is the correct spec for most data center and facility switchgear applications.
  • 45-Foot Length: 45 ft gives you enough slack to route from a facility panel or remote PDU to equipment without intermediate splicing. In large server rooms or mechanical spaces where panels are wall-mounted away from equipment rows, this reach matters — shorter cords force you into extension scenarios that complicate compliance and load calculations.
  • APC by Schneider Electric Sourcing: Factory-new, genuine product sourced through the APC supply chain — not grey-market or parallel import. For power infrastructure carrying 50A loads, provenance matters: counterfeit or substandard cordsets at this current rating are a fire and compliance risk.

Integration & Compatibility

This cordset is intended for use with APC PDUs, UPS output connections, and compatible facility power panels rated for 50A 3-phase service. Before deploying, confirm the connector type at both the equipment and the panel ends matches your installed infrastructure — APC publishes connector specifications per cordset model. Verify that your facility's branch circuit protection and panel ampacity are rated for sustained 50A draw, and confirm the 250V rating aligns with your supply voltage. This cord is appropriate for installation by qualified electricians familiar with 3-phase commercial wiring; this is not a field-terminated or self-service cordset category.

Facilities running APC Smart-UPS or Symmetra high-kVA systems, or large-format rack PDUs with 3-phase input, are the primary deployment targets for this cordset length and rating. If your load is single-phase or sub-30A, this cordset is overspecified — review the APC cordset family for the appropriate lower-amperage variant.

Frequently Asked Questions

Q: What connector types are on the 0M-5886-045?

A: Connector specifications are not confirmed in available evidence for this cordset. Contact APC by Schneider Electric or your pre-sales contact to verify the inlet and outlet connector types before ordering.

Q: Is the 0M-5886-045 rated for continuous 50A draw?

A: The cordset is rated at 50A / 250V. Per NEC and standard electrical practice, sustained continuous loads should not exceed 80% of the cord's rated ampacity (40A continuous) unless the cord is specifically rated for 100% continuous duty. Confirm duty-cycle requirements with your electrical engineer before deployment.

Q: Can I use this cordset outdoors or in wet locations?

A: Environmental ratings for the 0M-5886-045 are not confirmed in available evidence. This product is positioned for commercial and data center indoor use. Do not deploy in wet or outdoor environments without confirming the appropriate environmental rating with APC.

Q: Does this cordset come with a manufacturer warranty?

A: APC by Schneider Electric provides a manufacturer warranty on genuine cordset products. Specific warranty duration for the 0M-5886-045 is not confirmed in available evidence — contact APC directly to verify terms for this SKU.

Q: What is the wire gauge on the 0M-5886-045?

A: Wire gauge is not specified in available evidence for this cordset. At 50A / 250V over 45 feet, expect heavy-gauge conductors consistent with NEC requirements for this load and run length — verify the actual AWG with the APC product datasheet before installation.

Karl Wilson
Karl Wilson

The 0M-5886-045 sits in a segment of the APC cordset lineup that most integrators only touch when commissioning large UPS or high-density PDU infrastructure — the 50A / 250V 3-phase tier. At 45 feet, this is a cord you reach for when panel distance is the constraint, not just ampacity.

Technical Highlights:

  • 50A / 250V Rating: Covers the input requirements of high-kVA APC Symmetra and large Smart-UPS 3-phase configurations — most smaller installs never need this amperage tier, so spec-confirm before ordering.
  • 3P-4W Configuration: Four wires means neutral is present — critical for UPS and PDU designs that reference neutral for output distribution. A 3-wire-only cord at this class would be incompatible with those loads and is a common sourcing mistake on 3-phase projects.
  • 45-Foot Run: Long enough to route from a building switchgear room or remote panel to equipment without intermediate connections — intermediate splices at 50A introduce termination risk and complicate your electrical inspection.

Deployment Considerations:

  • Confirm connector type at both ends before the cord ships — APC uses multiple connector standards across their cordset family and mismatches at 50A are not field-fixable without proper tooling and a licensed electrician.
  • Size your branch circuit protection and panel ampacity for the full 50A rating even if your expected load is lower — NEC requires the overcurrent device to be rated for the cord, not just the anticipated draw.

This cordset is the right call for data center build-outs and large facility UPS commissioning where 3-phase 50A service is pre-planned from the panel design stage — not for retrofit or ad-hoc power runs where ampacity and connector type haven't been locked in advance.

Specifications
Amperage Rating: 50 A
Voltage Rating: 250 V
Poles: 3
Wires: 4
Length: 45 ft
Q&A
Reviews

APC by Schneider Electric Cordset 50A 250V 45FT - 0M-5886-045

$997.00
$677.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources