Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric 0M-6866 3-Pole 50A Circuit Breaker 120/240V

Overview

The APC by Schneider Electric 0M-6866 is a tested, three-pole 50-amp circuit breaker rated for 120/240V AC service — a purpose-built overcurrent protection component for commercial and industrial power distribution panels. If you're running high-draw loads across a three-phase or split-phase panel in a data center, equipment room, or building electrical infrastructure, this breaker is sized for the load without overbuilding the hardware budget. Factory-tested before leaving the facility, the 0M-6866 (often searched as 0M 6866) arrives ready to install and commission without additional bench verification.

Key Features

  • 50A Continuous Current Rating: Sized for high-draw branch circuits — appropriate for PDU feeds, HVAC compressor loads, or multi-rack equipment circuits where a 20A or 30A breaker would nuisance-trip under sustained draw. Running at 80% of rating per NEC code, this breaker handles up to 40A of continuous load.
  • Three-Pole Configuration: Protects all three legs of a circuit simultaneously. In a split-phase 240V panel, tripping one pole trips all three — critical for motor loads and three-wire equipment where leaving a phase energized after a fault creates a hazard. Single-pole breakers cannot provide this protection.
  • 120V/240V AC Dual Voltage Rating: Compatible with both standard North American 120V single-phase branch circuits and 240V split-phase loads. Versatile enough to serve a range of panel configurations without needing separate part numbers for different voltage tiers.
  • UL Listed: Meets Underwriters Laboratories standards for overcurrent protective devices — required for code compliance on commercial electrical installations in the United States. UL listing means the breaker has been independently evaluated for interrupting capacity, temperature rise, and trip accuracy.
  • Factory-Tested: The product title designates this as a tested unit, meaning trip characteristics and mechanical operation have been verified under load conditions prior to shipment. This matters for replacement scenarios where an untested breaker creates uncertainty in a live panel.
  • Compact Physical Footprint: At 12.50 × 8.50 × 4.50 inches and 2.1 lbs, this breaker ships in a manageable package. Verify your panel's breaker slot dimensions and bus compatibility before ordering — three-pole breakers consume three adjacent slots in a standard panel.

Integration and Compatibility

The 0M-6866 is an APC by Schneider Electric component intended for use with compatible Schneider Electric and APC panel boards and power distribution systems. Three-pole 50A breakers are common replacements in equipment rooms and server closets where APC PDUs or UPS systems feed downstream branch circuits. Before installation, cross-reference the breaker's frame size and bus stab configuration against your panel manufacturer's compatibility guide — breaker interchangeability between brands is not guaranteed even when ampere ratings match. Consult your panel's documentation or a licensed electrician to confirm bus bar compatibility and slot availability. This unit ships as a single breaker (packaged quantity of one).

Frequently Asked Questions

Q: What voltage is the APC 0M-6866 rated for?

A: The 0M-6866 is rated for 120V AC and 240V AC service, making it compatible with standard North American single-phase and split-phase panel configurations.

Q: Is the 0M-6866 UL listed?

A: Yes. The 0M-6866 complies with UL standards for circuit breakers, meeting requirements for commercial electrical installations in the United States.

Q: How many poles does the 0M-6866 have?

A: It is a three-pole breaker. This means it protects three conductors simultaneously and occupies three adjacent slots in a compatible panel.

Q: What is the continuous current rating for the 0M-6866?

A: The 0M-6866 is rated at 50 amps. Per NEC guidelines for continuous loads, plan the circuit for no more than 40A of sustained draw (80% of rated capacity).

Q: How many units are included per order?

A: Each order includes one (1) circuit breaker unit.

Q: What are the physical dimensions and weight of the 0M-6866?

A: The 0M-6866 measures 12.50 × 8.50 × 4.50 inches and weighs 2.1 lbs as packaged.

Jerry Tildsen
Jerry Tildsen

When I spec replacement breakers for equipment rooms, the combination that matters most is pole count, ampere rating, and voltage range — and the APC 0M-6866 checks all three for high-draw commercial branch circuits. The 50A three-pole configuration with 120/240V AC dual-voltage rating is the right profile for circuits feeding large UPS systems, motor loads, or multi-rack PDU feeds where a two-pole or lower-amp breaker simply won't carry the sustained current without false trips.

Technical Highlights:

  • 50A Three-Pole Rating: Handles up to 40A continuous under NEC 80% rule — appropriate for branch circuits serving APC PDUs or similarly sized equipment without nuisance tripping under sustained draw.
  • 120V/240V Dual Voltage: One part number covers both common North American panel voltages, reducing SKU proliferation when you're managing a mixed panel environment across a facility.
  • UL Listed: Code-required for commercial installations in the US — trip accuracy, interrupting capacity, and thermal performance have all been independently verified, not just self-certified.

Deployment Considerations:

  • Three-pole breakers consume three adjacent slots in a panel — verify available contiguous slots and bus bar stab compatibility with your specific panel model before ordering. Frame size mismatches between brands are a common and costly mistake on first replacement orders.
  • The 2.1 lb packaged weight and 12.50 × 8.50 × 4.50-inch package dimensions are the shipping spec, not the installed breaker dimensions — measure your panel's breaker bay before assuming fit based on package size alone.

The 0M-6866 is a solid fit for equipment rooms where an APC or Schneider Electric panel board is already in place and you need a verified, UL-listed 50A three-pole replacement without sourcing from outside the established panel ecosystem.

Specifications
Weight: 2.1 lbs
Dimensions: 12.50 x 8.50 x 4.50 in
Product Type: Circuit Breaker
Maximum Electric Current: 50 A
Voltage Required: 120V AC / 240V AC
Compliant Standards: UL
Q&A
Reviews

APC by Schneider Electric 3P 50A CKT BRKR 120/240 UL - 0M-6866

$342.00
$225.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources