Overview
Panduit UTP6AX7MRD Cat 6A 10Gig 7m Patch Cord - Red
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Overview
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit UTP6AX7MRD Cat 6A 10Gig UTP Patch Cord
The Panduit UTP6AX7MRD delivers certified 10GBASE-T performance in a 7-meter (23-foot) unshielded twisted pair patch cord engineered for high-density datacenter, server virtualization, and backbone aggregation deployments. Built on 24 AWG solid copper conductors with a slim 0.250-inch (6.4 mm) diameter jacket, this Cat 6A U/UTP cable exceeds ANSI/TIA-568.2-D and ISO 11801 Class EA specifications across the full 1–500 MHz frequency range while maintaining alien crosstalk immunity through internal foil tape shielding. The red PVC jacket simplifies color-coded patching schemes in equipment racks, and factory-installed RapidID barcodes enable one-scan port mapping and asset tracking through Panduit's RapidID software platform—eliminating manual labeling errors during moves, adds, and changes.
Key Features
- Certified 10 Gb/s Transmission: Exceeds Category 6A performance standards from 1 to 500 MHz, supporting 10GBASE-T Ethernet, parallel processing clusters, and high-speed computing interconnects
- PoE 802.3bt Type 4 Compatible: Delivers up to 90W per port for Ultra PoE applications including PTZ cameras, wireless access points, and LED lighting systems without voltage drop over 7-meter runs
- Tangle-Free Modular Plug Design: Low-profile strain relief boot and snag-resistant latch mechanism prevent cable entanglement in high-density patch panels and allow tool-free disconnection in confined spaces
- RapidID Asset Tracking: Pre-installed machine-readable barcodes integrate with RapidID port mapping software to auto-generate as-built documentation and reduce MAC cycle times by up to 60%
- 24 AWG Solid Copper Construction: Solid conductors provide lower DC resistance than stranded equivalents, ensuring consistent insertion loss and return loss performance across the installed base
- Red Jacket for Color-Coded Patching: High-visibility red PVC jacket meets CM fire rating and enables quick visual identification in mixed-application racks (security, data, VoIP)
The UTP6AX7MRD's U/UTP construction balances performance and cost for installations where shielded cabling infrastructure is not required. The internal foil tape around each twisted pair isolates conductors from external electromagnetic interference and limits alien crosstalk (AXT) between adjacent cables in densely populated cable bundles—a critical requirement for 10GBASE-T links in open-tray and overhead-ladder deployments. The 24 AWG solid copper conductors maintain a consistent 100-ohm impedance profile and deliver lower attenuation than stranded-conductor patch cords, making this cable suitable for semi-permanent equipment interconnects and horizontal cross-connects where flexibility is less critical than electrical performance. Factory-terminated modular plugs are wired to support both T568A and T568B pinouts, ensuring compatibility with existing structured cabling schemes without field retermination.
This 7-meter length bridges equipment racks in mid-sized datacenters, connects top-of-rack switches to adjacent server enclosures, and provides sufficient slack for overhead cable management in 42U cabinets without introducing excess coiled cable that degrades airflow. The tangle-free latch design features a recessed release tab that prevents snagging on adjacent patch cords during insertion and removal—a common failure mode in high-density 1U switch deployments where 48-port panels leave minimal clearance between RJ45 jacks. RapidID barcodes are laser-etched directly onto the cable jacket at both termination points, allowing technicians to scan each connection with a mobile device and auto-populate port assignments in Panduit's cloud-based cable management platform. This closed-loop documentation workflow eliminates the 12–18% error rate associated with manual spreadsheet-based tracking and provides real-time visibility into circuit provisioning for change management audits.
The UTP6AX7MRD is cULus listed under UL 1863 and CSA C22.2, meets FCC Part 68 (ANSI/TIA-1096-A) registration requirements for telecommunications equipment, and complies with IEC 60603-7 international connector standards. The cable is RoHS-compliant for lead-free installations and supports IEEE 802.3af (15.4W), 802.3at (30W), and 802.3bt Type 3 (60W) and Type 4 (90W) Power over Ethernet applications—delivering continuous 90W to endpoint devices over the full 7-meter run without exceeding the 10.2-ohm DC loop resistance threshold. Ships in cartons of 10 with individual retail packaging, providing integrators with bulk pricing and job-site logistics flexibility for multi-building campus rollouts and phased datacenter expansions.
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology