Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SYA8K16PX798 8kVA Scalable N+1 Tower UPS

Overview

The APC Symmetra LX SYA8K16PX798 is an 8,000 VA double-conversion online UPS designed for enterprise infrastructure environments where power interruptions are not an option. Starting at 8kVA and scalable to 16kVA, it pairs modular capacity growth with N+1 redundancy — meaning a single power module failure will not take your load offline. If you're protecting a mid-size data room, a broadcast head-end, or a dense network closet drawing 208V hardwired power, this is the architecture that keeps the load up regardless of what the utility delivers. The tower form factor fits on the floor or in a purpose-built enclosure without consuming rack space. Note that the web/SNMP management card ships separately with this configuration — factor that into your network monitoring plan before commissioning.

Key Features

  • Double Conversion Online Topology: The SYA8K16PX798 runs your load entirely off its inverter output at all times, isolating connected equipment from every form of utility anomaly — sags, swells, harmonics, and full outages. There is zero transfer time on loss of utility power because the load is never on bypass during normal operation. For server rooms or control systems that cannot tolerate even a 10ms switchover gap, this is the topology that eliminates the risk.
  • 8kVA / Scalable to 16kVA: The unit ships at 8,000 VA of usable output capacity but the chassis accommodates expansion to 16kVA by adding power modules — no forklift upgrade required. If you're commissioning a growing facility, starting at 8kVA and buying power modules as load increases is a practical capital-efficiency strategy rather than over-specifying from day one.
  • N+1 Redundancy Architecture: A redundant power module is included in the design so that any single module failure leaves the full rated load still supported. In a 24/7 operation — particularly one without an on-site electrician available around the clock — N+1 means you have time to schedule a repair without an emergency shutdown. This is the key differentiator from a standard single-module UPS at this VA class.
  • Hard Wire 4-Wire Output (2PH+N+G): Output connects via a hardwired 4-wire termination (two hot phases, neutral, and ground) rather than standard NEMA receptacles. This is appropriate for permanent equipment installs drawing sustained high current — panel-level connections handle the load without the thermal cycling risk of plug-in receptacles at high amperage. Plan for a licensed electrician at commissioning; this is not a plug-and-play deployment.
  • 208V / 240V Input Compatibility: The nominal input voltage is 208V, compatible with the two-phase commercial wiring standard common in North American data centers and equipment rooms. Verify your facility's panel voltage before ordering — this unit is not intended for standard 120V single-phase circuits.
  • Lead-Acid Battery Technology: Uses valve-regulated lead-acid (VRLA) batteries — a well-understood, field-serviceable chemistry with a wide replacement parts ecosystem. When runtime ends or batteries age out, replacement battery cartridges (RBC) are available through the APC channel, making lifecycle planning straightforward rather than dependent on proprietary cell formats.
  • Removable Input/Output Wiring Tray: The wiring tray design allows field technicians to disconnect and re-route conductors without removing the entire chassis. In a tight equipment room or during a scheduled maintenance window, this substantially reduces the time and complexity of any rewiring task.
  • RoHS Compliant, Mercury-Free: Meets RoHS environmental standards and contains no mercury — relevant for facilities with disposal or environmental compliance requirements, and increasingly required in government and enterprise procurement specifications.
  • 2-Year Manufacturer Warranty: The SYA8K16PX798 carries a 24-month standard manufacturer warranty on the core product, with a lifetime equipment protection policy available. Budget accordingly for extended coverage if the deployment is in a mission-critical environment with long refresh cycles.

Integration and Compatibility

This configuration ships without the network management card — the web/SNMP card must be ordered separately. Before commissioning, confirm which APC by Schneider Electric network management card (AP9631 or similar) is current-generation for this chassis, as card compatibility varies by UPS family and firmware revision. Once the card is installed, the unit integrates with APC PowerChute Network Shutdown for graceful OS-level shutdown orchestration across connected servers — essential in a virtualized environment where uncontrolled VM crashes carry data-loss risk. EcoStruxure IT cloud monitoring is also compatible for organizations running centralized power infrastructure visibility. For facilities with existing power protection and UPS infrastructure, verify that the Symmetra LX chassis is supported by your current management software version before deployment. Electrical integration requires a dedicated 208V two-phase circuit; coordinate with your facilities team on breaker sizing based on the 8kVA (or scaled) load plus appropriate headroom per NEC guidelines.

What's in the Box

Based on verified product evidence, the SYA8K16PX798 includes the following in the package:

  • 1x CD with software
  • 1x Installation guide
  • 1x User manual
  • 1x Web/SNMP Management Card (note: per product configuration, web card ships separately — confirm inclusion at time of order)

Frequently Asked Questions

Q: Does the SYA8K16PX798 include a network management card for SNMP monitoring?

A: No. This configuration ships with the web/SNMP management card listed as a separate item. You will need to order a compatible APC network management card (such as the AP9631) separately if remote monitoring or PowerChute Network Shutdown integration is required.

Q: What is the warranty on the SYA8K16PX798?

A: The core product carries a 24-month standard manufacturer warranty. A lifetime equipment protection policy is also available — contact APC or your procurement channel for terms and pricing on the extended coverage option.

Q: Can the SYA8K16PX798 be expanded beyond 8kVA without replacing the chassis?

A: Yes. The Symmetra LX platform is designed for in-place scalability — the chassis supports expansion to 16kVA by adding power modules, so you can grow capacity as your load increases without replacing the base unit.

Q: What input voltage does the SYA8K16PX798 require?

A: The nominal input voltage is 208V, consistent with two-phase commercial wiring common in North American data centers and equipment rooms. This unit is not compatible with standard single-phase 120V circuits. Verify your facility's panel voltage before ordering.

Q: Does the SYA8K16PX798 use a standard plug or hardwired connection?

A: Output is via hardwire 4-wire termination (2PH+N+G) — there are no NEMA receptacles on the output side. Installation requires a licensed electrician for both the input feed and the output connection to your load distribution panel or PDU.

Q: What battery type does the SYA8K16PX798 use, and are replacements available?

A: The unit uses valve-regulated lead-acid (VRLA) batteries. APC publishes replacement battery cartridge (RBC) part numbers for the Symmetra LX family, making end-of-life battery replacement a plannable maintenance event rather than a chassis replacement trigger.

Karl Wilson
Karl Wilson

The SYA8K16PX798 is the unit I recommend when a facility operator has a defined 208V hardwired load today but knows they're adding capacity over the next 18–36 months. The double-conversion online topology means the inverter is always carrying the load — not just switching in during an outage — so the quality of power your servers and storage see is completely decoupled from whatever the utility is doing. At 8,000 VA scalable to 16kVA in the same chassis, you're not ripping and replacing when you add another rack.

Technical Highlights:

  • Double Conversion Online: Zero transfer time on utility loss — the inverter is always carrying the load, so there's no 10–20ms gap that virtualization hosts and storage arrays would otherwise see as a brief power event.
  • N+1 Redundancy: A failed power module does not take the load down. In facilities without round-the-clock electrical staff, that means a daytime repair window instead of a 2am emergency response.
  • Hardwire 4-Wire Output: The 2PH+N+G termination handles sustained high-current loads cleanly — no NEMA receptacle thermal cycling at 8kVA draw. This is the correct output architecture for a permanent equipment room install, not a temporary deployment.

Deployment Considerations:

  • The web/SNMP management card does not ship with this SKU — order it separately before commissioning if PowerChute Network Shutdown or EcoStruxure IT visibility is part of your management plan. Discovering this gap post-install adds a service call.
  • At 482.99 lb (219 kg), this unit requires equipment-rated flooring, a pallet jack, and two-person placement. Factor rigging and facilities coordination into the installation timeline — this is not a one-tech rollout.

The SYA8K16PX798 fits best in a mid-size enterprise data room or network operations center running 208V two-phase infrastructure where N+1 redundancy is a stated uptime requirement and load growth over a multi-year horizon makes in-chassis scalability worth the per-kVA premium over a fixed-capacity alternative.

Specifications
Output Capacity: 8000 VA
Topology: Double Conversion Online
Output Connections: Hard Wire 4-wire (2PH+N+G) for 1 zone(s)
Input Voltage: 208 V
Height: 19.02 in (483 mm)
Width: 19.02 in (483 mm)
Depth: 28.58 in (726 mm)
Weight: 482.99 lb (219.08 kg)
Warranty: 24 month(s)
Battery Type: Lead-Acid battery
freight: 901.85
Q&A
Reviews

APC by Schneider Electric SYA8K16PX798 8kVA Tower

$18,110.00
$12,186.99

RELATED PRODUCTS

Save $7,948.01
APC Symmetra LX 8KVA Scalable to 16KVA N+1 Tower 220/230/240V or 480/400/415V -
Add to Cart The item has been added

APC by Schneider Electric SYA8K16I

APC by Schneider Electric SYA8K16I 8KVA Tower

Modular, scalable uninterruptible power supply rated at 8 kVA (5,600 W) with a growth path to 16 kVA — purpose-built for mission-critical

    Usually Ships in 2-3 Weeks Free shipping over $499
    $23,340.00 $15,391.99 Save $7,948.01
    The item has been added Add to quote
    $23,340.00 $15,391.99 Save $7,948.01
    Save $7,948.01 Add to cart Add to quote
    Save $8,533.01
    APC Symmetra LX 8KVA Scalable to 8KVA N+1 Tower 220/230/240 or 380/400/415V - SY
    Add to Cart The item has been added

    APC by Schneider Electric SYA8K8I

    APC by Schneider Electric SYA8K8I 8KVA Tower

    N 8kVA (5,600W) scalable tower UPS built around an N+1 redundant architecture — the configuration that keeps critical loads running even when one

      Usually Ships in 2-3 Weeks Free shipping over $499
      $24,615.00 $16,081.99 Save $8,533.01
      The item has been added Add to quote
      $24,615.00 $16,081.99 Save $8,533.01
      Save $8,533.01 Add to cart Add to quote
      Save $5,038.01
      APC Symmetra LX 8KVA Scalable to 16KVA N+1 Tower 220-240V or 480-415V WEB Card - SYA8K16IX798
      Add to Cart The item has been added

      APC by Schneider Electric SYA8K16IX798

      APC by Schneider Electric SYA8K16IX798 8KVA Tower

      Symmetra LX modular tower UPS rated at 8KVA with online scalability to 16KVA and built-in N+1 power module redundancy — designed for installations

        Usually Ships in 2-3 Weeks Free shipping over $499
        $16,150.00 $11,111.99 Save $5,038.01
        The item has been added Add to quote
        $16,150.00 $11,111.99 Save $5,038.01
        Save $5,038.01 Add to cart Add to quote
        Save $4,809.01
        APC Smart-ups On-line, 8KVA/8KW, Rackmount 6U, 208V, 4X L6-20R+2X L6-30R NEMA OU
        Add to Cart The item has been added

        APC by Schneider Electric SRT8KRMXLT

        APC by Schneider Electric 8KVA UPS - SRT8KRMXLT

        N 8kVA/8kW double-conversion online UPS engineered for rackmount deployments where clean, uninterrupted power is non-negotiable

          In stock · Ships same business day Free shipping over $499
          $15,165.00 $10,355.99 Save $4,809.01
          The item has been added Add to quote
          $15,165.00 $10,355.99 Save $4,809.01
          Save $4,809.01 Add to cart Add to quote
          Save $7,685.01
          APC Smart-ups Ultra On-line Lithium ION 8KVA/8KW 4U Rack/tower 208/240V - SRTL8KRM4UT
          Add to Cart The item has been added

          APC by Schneider Electric SRTL8KRM4UT

          APC by Schneider Electric 8KVA/8KW 4U Rack/Tower UPS - SRTL8KRM4UT

          N 8kVA/8kW on-line, double-conversion UPS designed to deliver clean, continuous power to critical IT equipment

            Usually Ships in 2-3 Weeks Free shipping over $499
            $23,505.00 $15,819.99 Save $7,685.01
            The item has been added Add to quote
            $23,505.00 $15,819.99 Save $7,685.01
            Save $7,685.01 Add to cart Add to quote

            System Design, Deployment & Technical Support

            Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

            Fixed scope • Fixed price

            System Design Assistance

            • Get help validating product compatibility
            • Coverage requirements
            • Storage planning and deployment architecture before you buy.
            Request Design Help

            Deployment & Configuration Support

            • Access fixed-scope support for rollout planning
            • User setup guidance
            • Migration and system standardization across single-site or multi-site deployments
            View Support Services

            Guides, Tools & Calculators

            • PoE requirements
            • Storage retention
            • Camera selection and deployment methodology
            Open Technical Resources