Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: SRT8KRMXLT-IEC
UPC: 731304304302
Condition: New
Write a Review 33% OFF

APC Smart-ups SRT 8000VA RM 208V IEC - SRT8KRMXLT-IEC

APC by Schneider Electric SRT8KRMXLT-IEC 8kVA Online Double-Conversion Rack UPS 208V IECOverviewThe APC Smart-UPS SRT8KRMXLT-IEC is an 8000VA / 8000W …

$15,500.00 $10,369.99 SAVE $5130
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Smart-ups SRT 8000VA RM 208V IEC - SRT8KRMXLT-IEC

$15,500.00
$10,369.99

Overview

SKU: SRT8KRMXLT-IEC
UPC: 731304304302
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SRT8KRMXLT-IEC 8kVA Online Double-Conversion Rack UPS 208V IEC

Overview

The APC Smart-UPS SRT8KRMXLT-IEC is an 8000VA / 8000W double-conversion online UPS in a rack-mount form factor, designed for 208V IT environments that require zero-transfer-time power conditioning with true sine wave output. At the SRT8KRMXLT-IEC's power class, this unit is sized for high-density server rows, edge data closets, and critical surveillance infrastructure where a momentary power sag or switchover delay would interrupt recording, access control, or network uptime. Unlike standby or line-interactive designs, the double-conversion topology means your equipment is always running off the inverter — the raw utility feed never reaches your servers directly, so line noise, voltage swings from 100V to 275V input, and frequency excursions from 40 to 70 Hz are all absorbed without any transfer gap.

The IEC outlet configuration — a mix of C13 and C19 couplers — matches the standard connector inventory on rack-mount servers, switches, PDUs, and high-wattage appliances, making it a natural fit for equipment rooms that have standardized on IEC power distribution rather than NEMA strips. For power protection and UPS systems, the SRT8KRMXLT-IEC represents the high-capacity end of APC's Smart-UPS SRT line.

Key Features

  • Double-Conversion Online Topology: The inverter is always in the power path — no transfer time, no relay switching. For network video recorders or RAID storage arrays that are sensitive to even a half-cycle interruption, this is the topology that eliminates the risk entirely. Line-interactive units transfer in 2–6ms; this unit transfers in 0ms because it never switches.
  • 8000VA / 8000W Output (Unity Power Factor): A 1.0 power factor rating means the VA and watt figures are the same — no derating required. If your load calculations total 6.5kW, you have genuine headroom without needing to factor in a correction coefficient. This is a meaningful differentiator over older UPS designs that rated at 0.8 or 0.9 PF.
  • Wide Input Voltage Acceptance (100–275V AC): The SRT8KRMXLT-IEC accepts input from 100V to 275V, which means it can absorb browndowns and voltage spikes that would force a lower-tolerance UPS onto battery unnecessarily. Less time on battery = less battery wear = longer battery service life in environments with chronic utility instability.
  • Broad Input Frequency Tolerance (40–70 Hz): Generator sets often run at unstable frequencies during startup or under varying load. A 40–70 Hz acceptance window lets the UPS accept generator power without switching to battery, which is critical for data centers or camera infrastructure that must survive utility outages backed by on-site gen sets.
  • True Sine Wave Output: Active PFC power supplies — standard in modern servers, managed switches, and IP camera systems — require a true sine wave input. The SRT8KRMXLT-IEC delivers a clean sine waveform on battery, avoiding the compatibility issues and potential supply damage that modified-wave units can cause.
  • Output Voltage THD Below 2%: At less than 2% total harmonic distortion on the output, downstream equipment receives cleaner power than most utility feeds provide. For sensitive analog-to-digital conversion hardware, precision timing systems, or industrial control gear sharing the same rack, low THD prevents measurement drift and unexplained reboots caused by power quality issues.
  • Emergency Power Off (EPO): The EPO input allows integration with building management systems or data center emergency shutdown circuits. In a fire suppression event or emergency evacuation scenario, EPO enables a single hardwired signal to de-energize the UPS without manual intervention at the unit — a requirement for many commercial facility codes and a standard checklist item in data center commissioning.
  • 3:1 Crest Factor Tolerance: High crest factor loads — motor startups, UPS-on-UPS configurations, large power supplies — draw peak currents that can exceed their RMS rating by 3x or more. A 3:1 crest factor rating ensures the inverter doesn't clip or fault under those transient peaks, which is relevant if you're powering mixed rack content including edge compute or industrial gear.
  • 480J Surge Energy Rating with Active Surge Protection: The built-in surge protection absorbs up to 480 joules of transient energy, providing a backstop against lightning-induced surges on the utility feed even when the system is in online double-conversion mode.
  • Web-Based Management Interface: Onboard web management enables remote monitoring of load levels, battery status, event logs, and configuration — without requiring a separate network management card in every deployment. For network infrastructure installations where physical access to the equipment room is limited, remote visibility into UPS status is operationally necessary, not optional.
  • Audible Alarms: Configurable audible alerts for on-battery, low battery, overload, and fault conditions provide local awareness without requiring continuous remote monitoring. Useful during commissioning and useful in unmanned equipment rooms where a technician may be physically present but not watching a dashboard.
  • 55 dB Noise Level: At 55 dB, the SRT8KRMXLT-IEC is audible in a quiet office environment but within the normal range for active equipment rooms. If this unit is being installed in a noise-sensitive space — broadcast control room, executive suite, clinical environment — factor the fan noise into placement decisions.

Integration and Compatibility

The SRT8KRMXLT-IEC is designed for rack-mount integration and outputs 208V AC with IEC C13 and C19 outlet couplers — the standard connector types for rack-mount servers, patch panels, and high-draw appliances. The IEC outlet mix allows direct connection to most rack-mount enterprise hardware without adapter cables. Web-based management supports remote load monitoring and UPS configuration. The EPO terminal integrates with facility-level emergency shutdown systems per standard data center wiring practices. For organizations building out APC UPS solutions, the SRT8KRMXLT-IEC fits within the Smart-UPS SRT family's ecosystem, which includes external battery packs and network management accessories. Input frequency acceptance from 40–70 Hz ensures compatibility with generator sources during utility failover — a non-trivial consideration for any critical infrastructure installation that relies on backup generation (SRT8KRMXLT-IEC is often searched as SRT8KRMXLT IEC).

Frequently Asked Questions

Q: What is the difference between the SRT8KRMXLT-IEC and a line-interactive UPS at the same VA rating?

A: The SRT8KRMXLT-IEC uses double-conversion online topology, meaning the inverter is always in the power path with zero transfer time. A line-interactive UPS switches to battery when utility power falls outside acceptable limits, introducing a 2–6ms transfer delay. For servers and storage systems running active PFC power supplies, zero transfer time eliminates any risk of a momentary interruption during the switchover.

Q: Does the SRT8KRMXLT-IEC support generator input?

A: Yes. The unit accepts input frequencies from 40 to 70 Hz, which accommodates generator sets that run at unstable frequencies during startup or under varying load. This allows the UPS to ride through generator fluctuations without switching to battery unnecessarily.

Q: What outlet types are on the SRT8KRMXLT-IEC?

A: The SRT8KRMXLT-IEC provides IEC C13 and IEC C19 coupler outlets. C13 outlets serve standard rack-mount servers and networking equipment; C19 outlets handle higher-draw devices. Both are the international standard for rack power distribution and do not require NEMA adapters for typical data center hardware.

Q: Does the SRT8KRMXLT-IEC include Emergency Power Off (EPO) capability?

A: Yes. The unit includes an EPO input that integrates with building management or emergency shutdown systems. A single hardwired signal can de-energize the UPS during a fire suppression event or emergency evacuation without manual operation at the unit.

Q: What is the output voltage THD of the SRT8KRMXLT-IEC?

A: Output voltage total harmonic distortion is less than 2%, which is cleaner than most utility feeds. This benefits sensitive equipment — servers, storage arrays, and precision electronics — that can be affected by power quality issues.

Q: Can the SRT8KRMXLT-IEC be managed remotely?

A: Yes. The unit includes a web-based management interface for remote monitoring of load, battery status, event logs, and configuration without requiring a separate network management card.

Marty Allison
Marty Allison

The SRT8KRMXLT-IEC's double-conversion topology is the spec that matters most at this power class — 8000VA with a unity (1.0) power factor means you get 8000W of usable output, not the 6,400W you'd see from an 0.8 PF unit of the same VA rating. That's a real capacity difference when you're sizing for a dense rack or a camera head-end with 30+ PoE devices on a managed switch stack.

Technical Highlights:

  • 100–275V Input Range: Accepts utility voltages across an unusually wide band, which means chronic browndowns or regional voltage instability won't push the unit onto battery prematurely — extending battery service life in environments where utility quality is inconsistent.
  • Sub-2% Output THD: The inverter delivers cleaner power than many utility feeds. For surveillance infrastructure mixing IP cameras, NVRs, and managed switches on shared rack power, lower THD reduces unexplained reboots and network instability from power quality.
  • 40–70 Hz Frequency Window: Generator compatibility without battery switching is a real operational requirement for any facility that relies on on-site generation during outages. Most UPS units accept 47–63 Hz; the SRT8KRMXLT-IEC's wider window reduces battery dependency during gen-set startup transients.

Deployment Considerations:

  • EPO wiring requires coordination with the facility's emergency shutdown circuit — confirm the EPO input voltage/contact type against your building's BMS or suppression system before commissioning.
  • At 55 dB, fan noise is perceptible in quiet environments. If this unit is destined for an executive suite, clinical space, or broadcast control room rather than a dedicated equipment room, evaluate acoustics before committing to placement.

The SRT8KRMXLT-IEC is the right fit for edge data closets and mid-size equipment rooms running 208V IEC rack infrastructure — particularly those that need generator compatibility and EPO integration baked in at the UPS level rather than added as an afterthought.

Specifications
UPS topology: Double-conversion (Online)
Output power capacity: 8 kVA
Output power: 8000 W
Waveform: Sine
Input operation voltage (min: 100 V
Input operation voltage (max: 275 V
Input frequency: 40 - 70 Hz
Output operation voltage (max: 208 V
Output frequency: 50/60 Hz
Surge energy rating: 480 J
Crest factor: 3:1
Emergency Power Off (EPO: Yes
Output voltage Total Harmonic Distortion (THD: 2%
Noise level: 55 dB
Surge protection: Yes
Audible alarm(s: Yes
Web-based management: Yes
AC outlet types: C13 coupler, C19 coupler
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources