APC Power Cords Input Connections: NEMA L6-20P Cord Length: 12 Feet ( 3.66 M - AP9871

APC by Schneider Electric AP9871 NEMA L6-20P 12-Foot Power CordOverviewThe AP9871 is a 12-foot (3.66 m) replacement or extension power cord from APC b…

$90.00 $89.99 SAVE $0
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Power Cords Input Connections: NEMA L6-20P Cord Length: 12 Feet ( 3.66 M - AP9871

$90.00
$89.99

Overview

SKU: AP9871
UPC: 731304111030
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP9871 NEMA L6-20P 12-Foot Power Cord

Overview

The AP9871 is a 12-foot (3.66 m) replacement or extension power cord from APC by Schneider Electric, fitted with a NEMA L6-20P locking plug. That twist-lock connector means once it's seated, it won't vibrate loose — critical in raised-floor data centers, network closets, and equipment rooms where a dropped connection means downtime. At 12 feet, it gives you enough slack to route cleanly from floor-mounted PDUs to rack-mounted UPS units without forcing tight bends that stress conductors over time. The AP9871 is rated for operation from 0 to 45 °C, covering virtually every conditioned indoor equipment space.

Compatibility

The NEMA L6-20P input plug is a 20A, 250V locking connector — verify your PDU, UPS, or in-line power device has a matching NEMA L6-20R receptacle before ordering. This connector type is standard on many APC by Schneider Electric rack PDUs and UPS units in the Smart-UPS and Symmetra families, as well as third-party 240V-input rack power distribution equipment. It is not compatible with NEMA 5-series (120V) receptacles or IEC C13/C19 outlets — those require different cord models in the APC power distribution accessories line. If you are wiring a network switch rack or surveillance NVR enclosure that draws from 208/240V PDU rails, this cord is the correct bridging piece between the PDU output and a downstream device with an L6-20R inlet.

Installation Notes

The NEMA L6-20P connector locks by inserting and rotating clockwise until it seats — no tools required, but confirm the mating receptacle is de-energized before connecting. Storage and transport are rated to -25 to 65 °C with up to 95% relative humidity (non-condensing), so field storage in unconditioned staging areas is acceptable short-term. Rated operating elevation reaches 10,000 feet, covering high-altitude data center deployments without derating concerns. Route the cord away from sharp edges and avoid kinking — a cable management arm or horizontal manager keeps the 12-foot length organized in a two-post or four-post rack. Do not exceed the 20A circuit rating of the L6-20P connector; confirm upstream breaker sizing matches before commissioning.

Specifications
Operating Environment: 0 to 45 °C
Storage Temperature: -25 to 65 °C
Operating Relative Humidity: 0 to 95 %
Storage Relative Humidity: 0 to 95 %
Operating Elevation: 0 to 10000 feet
Storage Elevation: 0 to 50000 feet
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources