APC Netshelter Rack PDU Advanced Metered 34.6KW 3PH 415V 60A 560P6 42 OUT - APDU11450ME

APC by Schneider Electric APDU11450ME Advanced Metered Rack PDU 34.6KW 3PH 415VThe APDU11450ME is a high-density, 3-phase advanced metered rack PDU en…

$5,870.00 $3,905.99 SAVE $1964
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter Rack PDU Advanced Metered 34.6KW 3PH 415V 60A 560P6 42 OUT - APDU11450ME

$5,870.00
$3,905.99

Overview

SKU: APDU11450ME
UPC: 731304752783
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU11450ME Advanced Metered Rack PDU 34.6KW 3PH 415V

The APDU11450ME is a high-density, 3-phase advanced metered rack PDU engineered for data centers and enterprise server rooms where granular power visibility and high-capacity load distribution are non-negotiable. Rated at 34,600 VA across a 415V 3-phase input, it handles serious compute and storage densities without requiring multiple lower-capacity units — one PDU covers a fully loaded high-density cabinet. If you're provisioning network infrastructure or rack power distribution for a dense server deployment, this unit belongs in the conversation early.

Key Features

  • 34.6KW / 60A Load Capacity at 415V 3-Phase: Supports full-density racks with power-hungry compute, storage, or networking gear. The 60A input via NEMA L6-30P means you're drawing near-full cabinet capacity without paralleling PDUs — fewer units, simpler cable management, lower failure surface area.
  • 1% Metering Accuracy: Outlet-level or inlet-level readings within 1% give you trustworthy data for chargeback, capacity planning, and anomaly detection. Guesswork on power draw is how you get surprise overloads — 1% accuracy closes that gap for any data center infrastructure team managing SLA commitments.
  • 42 Output Connections (21 C13/C15 + 21 C13/C15/C19/C21): Mixed IEC outlet groupings cover standard servers (C13), high-draw compute (C19), and specialty loads (C21) without adapters. The outlet mix handles heterogeneous racks — blade servers alongside GPU nodes alongside storage arrays.
  • Gigabit Ethernet Network Port with 2-Port Sharing: The onboard 10/100/1000 Ethernet port connects to your DCIM or NMS platform for remote monitoring without a dedicated management server. Network Port Sharing supports up to 32 PDUs on a single IP — critical for reducing IP address consumption in managed data halls.
  • Up to 60°C Operating Temperature: Rated to 140°F operating ambient, this unit stays functional in hot-aisle/cold-aisle configurations that run warm by design — no derating required in moderately elevated thermal environments.
  • 10 ft. (3 m) Input Cord: The 3-meter cord reaches overhead busway or floor-mounted distribution panels without extension hardware in standard 600mm-deep cabinet rows — eliminating a common site-survey oversight.

Integration and Compatibility

The APDU11450ME integrates with APC's EcoStruxure IT platform and third-party DCIM systems via its gigabit network interface. The two link ports enable rack PDU daisy-chaining for network port sharing across up to 32 units — a meaningful consolidation for large deployments. The 415V 3-phase input is standard in international and European data center infrastructure, so confirm your local feed voltage matches before ordering. NEMA L6-30P input plug — verify your PDU panel or busway tap is compatible at installation planning stage.

Frequently Asked Questions

Q: What input plug does the APDU11450ME use?

A: The APDU11450ME uses a NEMA L6-30P input plug on a 10 ft. (3 m) cord. Verify your distribution panel or busway tap accepts this connector before installation.

Q: How many PDUs can share a single network port?

A: Up to 32 PDUs can share a single IP address using the two link ports and APC Network Port Sharing — reducing IP overhead significantly in large data hall deployments.

Q: What is the metering accuracy of the APDU11450ME?

A: Metering accuracy is 1%, suitable for chargeback billing, capacity planning, and reliable overload detection.

Q: What outlet types are included?

A: The unit provides 42 total outlets: 21 C13/C15 and 21 C13/C15/C19/C21 — covering standard servers, high-draw compute (C19), and specialty loads (C21).

Q: What is the maximum operating temperature?

A: The APDU11450ME is rated for operation up to 60°C (140°F), suitable for warm-aisle data center configurations.

Marty Allison
Marty Allison

The APDU11450ME is built for deployments where power density is high and metering accuracy actually matters for billing or capacity headroom decisions. The 34,600 VA / 60A input at 415V 3-phase is the spec that tells you what rack environments this belongs in — high-density compute, colocation cabinets, or any infrastructure where a single PDU needs to carry a full cabinet load without a second unit paralleled alongside it.

Technical Highlights:

  • 1% Metering Accuracy: At this accuracy level, power readings are usable for actual chargeback invoicing — not just rough capacity estimates. In multi-tenant colo environments, that distinction matters operationally.
  • 32-PDU Network Port Sharing: Two link ports support up to 32 units per IP — in a 100-cabinet data hall, that's three IP addresses managing the entire PDU layer rather than 100. Simplifies DCIM integration and VLAN planning considerably.
  • 42 Mixed IEC Outlets: The C13/C15/C19/C21 mix means you're not adaptering high-draw nodes. C19 directly feeds blade enclosures and GPU servers; C21 handles specialty PDU-fed equipment — no field modifications needed for a heterogeneous rack.

Deployment Considerations:

  • The NEMA L6-30P plug and 415V 3-phase input are standard for international and European data center feeds — confirm local panel compatibility during site survey, not at installation day.
  • The 10 ft. cord reaches standard overhead busway in most 600mm-deep cabinet rows, but measure your tap-to-PDU run before assuming adequacy in non-standard rack orientations.

The APDU11450ME fits best in colocation deployments, high-density enterprise server rooms, and international data center builds where 415V 3-phase infrastructure is already in place and per-outlet metering data feeds a real DCIM or chargeback workflow.

Specifications
Pdu Type: Metered
Network Port Sharing: 32
Connectivity Ports: One 10/100/1000 network or gigabit Ethernet port and two link ports for network port sharing
Metering Accuracy: 1%
Output Connections: (21) C13/C15/C19/C21 (21) C13/C15
Input Voltage: 415 V 3 Phase
Input Plug: NEMA L6-30P
Cord Length: 10 ft. (3 m)
Maximum Current: 60 A
Load Capacity: 34600 VA
Operating Temperature: Up to 60 C (140 F)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources