Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU11454SM is a 2U horizontal rack PDU from APC's Netshelter Advanced 11K series, purpose-built for high-density three-phase data center and server room deployments where per-outlet control and granular power metering are non-negotiable. Running at a nominal 415 V three-phase input with a 60 A maximum current draw and a 41,400 VA load capacity, this unit is sized for dense compute rows, AI inference clusters, and enterprise network equipment racks where aggregate power demands routinely push into the tens of kilowatts. If you're managing power across a multi-rack data hall and need remote outlet-level switching without dedicated PDU controllers, this is the tier of product to evaluate.
The unit ships in a black horizontal form factor designed to occupy 2U of standard rack space, keeping vertical real estate available for the high-density compute or networking gear it's powering. Managed via APC's NMC3 platform, the APDU11454SM integrates into existing data center infrastructure management (DCIM) environments with a well-supported management card ecosystem.
The APDU11454SM connects to APC's NMC3 management ecosystem, which supports integration with EcoStruxure IT Gateway, SNMP v1/v2c/v3 monitoring, and third-party DCIM platforms. The mixed outlet array (C13, C15, C19, C21) accommodates virtually all enterprise server and networking equipment cord standards. Three-phase deployment requires a matching three-phase UPS or three-phase power distribution infrastructure — verify your upstream UPS output receptacle matches the IEC 309 input specification before commissioning. For large deployments, APC's EcoStruxure IT can aggregate telemetry from multiple APDU11454SM units into a unified power dashboard across the data hall. Pair this PDU with compatible APC UPS systems for a fully integrated power protection and management chain.
Q: What is the maximum load capacity of the APDU11454SM?
A: The APDU11454SM supports up to 41,400 VA (41.4 kVA) at 415 V three-phase input with a 60 A maximum current draw. Plan your load at no more than 80% of this ceiling for stable continuous operation.
Q: What outlet types does the APDU11454SM provide?
A: The unit provides 18 AC outlets across four IEC connector types: C13, C15, C19, and C21. This mix accommodates standard 1U servers, higher-draw compute, and elevated-temperature-rated equipment. Verify the per-type outlet count in the product documentation before designing your cable plan.
Q: Can I remotely power-cycle individual outlets on the APDU11454SM?
A: Yes. As a switched metered-by-outlet PDU, the APDU11454SM allows remote on/off control of individual outlets via the NMC3 management card — enabling remote server power cycles, scheduled shutdowns, and outlet-level load management without physical access to the rack.
Q: What management platform does the APDU11454SM use?
A: It uses APC's NMC3 (Network Management Card 3) platform, which supports SNMP monitoring, EcoStruxure IT integration, and standard data center management protocols for remote monitoring, alerting, and control.
Q: Is the APDU11454SM suitable for outdoor or high-humidity environments?
A: The APDU11454SM carries an IP44 rating, providing protection against solid objects over 1mm and water splash from any direction. It is not rated for washdown, submersion, or high-humidity industrial environments. Operating relative humidity range is 5–90% non-condensing.
Q: What input connector does the APDU11454SM require?
A: The unit uses an IEC 309 three-phase input connector — the industrial-standard locking connector for three-phase data center power. This is not a standard NEMA plug; your power infrastructure must be provisioned for IEC 309 before installation.

The APDU11454SM sits at the serious end of the three-phase PDU market — its 41,400 VA load capacity at 415 V three-phase and NMC3-managed per-outlet switching put it squarely in enterprise data center territory, not in a small-room UPS closet. When I spec this unit, the conversation starts with the 60 A maximum current and works backward to the rack design; if your upstream three-phase circuit isn't provisioned for IEC 309 at that amperage, the rest of the PDU's capabilities don't matter.
Technical Highlights:
Deployment Considerations:
The APDU11454SM is a strong fit for enterprise colocation deployments, AI compute clusters, and high-density network equipment rows where per-outlet accountability and remote power management are architectural requirements, not optional add-ons.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price