Door Hardware & I/O
Sub categories
Showing Results for Door Hardware & I/O
-
HES
SKU: 805-630
HES 805-630 Flat Faceplate Satin Stainless
Satin stainless flat faceplate for HES 8000/8300 strike systems
- Flat faceplate with radius corners fits standard door frames for clean installs.
- Satin stainless steel construction resists corrosion in high-moisture environments.
- Direct compatibility with HES 8000 and 8300 series simplifies strike replacement.
$64.00 $63.99 Save $0.01 -
HES
SKU: 8055-01-628
HES 8055-01-628 Tall Door Kit
Tall door kit extends HES electric strike reach for non-standard heights
- Works with HES electric strike systems for elevated frame installations
- Accommodates non-standard door heights beyond standard strike kit specs
- Certified integrator installation required for commercial and institutional use
$172.00 $171.99 Save $0.01 -
HES
SKU: 8100-MLRM-36-32DMEC
HES 8100-MLRM-36-32DMEC SVR MLR Exit Device
SVR MLR exit device for 12V/24V access control systems
- Single Voltage Relay with Multi-Logic Relay for flexible signal routing
- Controls door strikes and electromagnetic locks with low-power relay contacts
- Field-installable surface-mount and recessed compatible, UL-listed
$3,265.00 $1,627.99 Save $1,637.01 -
HES
SKU: 8414-37136
HES 8414-37136 Life-Safety Narrow Stile Mortise Exit Device
Mortise exit device for narrow stile aluminum/glass doors, 1-1/8" backset
- Mortise-mounted design fits tight aluminum and glass door frames without external profile
- 1-1/8" backset matches standard narrow stile door pocket geometry for direct retrofit
- Ships without monitoring switch—add your own system or use standalone mechanical operation
$950.00 $473.99 Save $476.01 -
HES
SKU: 8414-38136
HES 8414-38136 Life-Safety Narrow Stile Mortise Exit Device
Life-safety mortise exit for narrow stile aluminum and glass doors
- Mortise-mount design with 1-1/8 inch backset fits standard narrow stile preparations
- Life-safety certified for emergency egress compliance in commercial and institutional settings
- Internal cavity installation minimizes visible hardware on door surface
$950.00 $473.99 Save $476.01 -
HES
SKU: 851M-630
HES 851M-630 Faceplate Satin Stainless Steel
Satin stainless steel faceplate for HES 851M electric strike systems
- Satin stainless steel construction resists corrosion in interior and exterior deployments.
- Direct compatibility with HES 851M electric strike systems simplifies retrofits and new installs.
- Faceplate form factor fits standard door frame preps; supports 12VDC electric strike wiring.
$55.00 $54.99 Save $0.01 -
HES
SKU: 852K-630
HES 852K-630 Faceplate for 852 Series Locks
Replacement faceplate for HES 852 series electromechanical locks
- Faceplate for the HES 852 series electromechanical locks
- Direct-fit replacement for indoor commercial doors
- Maintains finished appearance after lock swap
$55.00 $54.99 Save $0.01 -
HES
SKU: 852L-630
HES 852L-630 Electric Strike Faceplate
HES 852L faceplate for commercial strike mounting and finish
- Faceplate for the HES 852L series electric strike
- Direct OEM-fit for standard commercial door frames
- 12VDC strike-faceplate spare for institutional doors
$55.00 $54.99 Save $0.01 -
HES
SKU: 852M-630
HES 852M-630 Faceplate for Access Control
HES 852M-630 faceplate for wall and flush-mount access control
- Fits HES 852 series control modules for drop-in replacement with no rewiring.
- Supports both wall-mounted and flush-mount configurations for flexible deployment.
- Operates on 12VDC input, compatible with standard access control power infrastructure.
$55.00 $54.99 Save $0.01 -
HES
SKU: 856LED
HES 856LED Replacement LEDs TS-2 Series 5-Pack
5-pack replacement LEDs for HES TS-2 access control status indicators
- Direct-fit replacements for HES TS-2 series require no modification to install.
- Five-pack quantity supports multi-door deployments and spare parts inventory.
- Genuine HES components ensure reliable status indicator compatibility on TS-2 devices.
$45.00 $44.99 Save $0.01 -
HES
SKU: 8600-MLRM2-30-US32D
HES 8600-MLRM2-30-US32D Motorized Latch Retraction
Motorized latch retraction, 30" opening, dual-switch control for access doors
- Fail-safe and fail-secure configurable modes with independent command circuits
- Satin stainless steel (300-series) construction for durability in high-traffic areas
- 24VDC motorized actuation with status feedback for access control integration
$2,645.00 $1,318.99 Save $1,326.01 -
HES
SKU: 9000-108-630
HES 9000-108-630 Spacer Kit 1/8 Plate Satin Stainless
1/8" satin stainless spacer for HES 9000 Series strike alignment
- 1/8" plate thickness corrects frame-to-strike gaps without over-shimming or binding.
- Satin stainless steel resists corrosion in indoor and semi-protected transition environments.
- Direct HES 9000 Series compatibility eliminates custom drilling or field rework on install.
$45.00 $44.99 Save $0.01 -
HES
SKU: 9000-116-628E
HES 9000-116-628E Spacer Plate 1/16 Inch
1/16" precision spacer plate for HES 9000 Series lock mounting
- 1/16-inch precision thickness eliminates shimming and ensures repeatable alignment.
- Designed exclusively for HES 9000 Series hardware for drop-in fit without modification.
- US-made construction at 0.2 lb keeps hardware weight minimal in multi-unit deployments.
$62.00 $61.99 Save $0.01 -
HES
SKU: 9000-116-630
HES 9000-116-630 Spacer Kit 1/16 Satin Stainless
1/16" satin stainless spacer plates for HES 9000 Series locks
- 1/16" satin stainless steel construction resists corrosion in demanding environments.
- Engineered for HES 9000 Series, ensuring precise strike alignment and reliable lock engagement.
- Eliminates frame gaps that compromise electromagnetic lock performance in access control installs.
$45.00 $44.99 Save $0.01 -
HES
SKU: 9000-ASB-613E
HES 9000-ASB-613E Aluminum Spacer Bracket
Aluminum spacer bracket for HES 9000 Series interior/exterior mounting
- Dark oxidized bronze finish resists corrosion in exterior applications
- Lightweight aluminum construction supports precise component alignment
- Compatible with HES 9000 Series electric strike and access control systems
$146.00 $145.99 Save $0.01 -
HES
SKU: 9000-ASB-628
HES 9000-ASB-628 Aluminum Spacer Bracket
Aluminum spacer bracket for precise HES 9000 series mounting
- Satin anodized aluminum resists corrosion in humid environments
- Standardized spacing eliminates field shimming across retrofit projects
- Lightweight 1.25 lb design supports repeatable installation positioning
$134.00 $133.99 Save $0.01
Door Hardware & I/O
Door hardware and I/O components connect physical doors to your access control system. From electric strikes and magnetic locks to exit devices and relay modules, proper hardware selection ensures safe, compliant, and reliable operation.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type (wood, metal, glass, storefront)
- Request-to-exit (REX) device requirements
- Power supply and voltage compatibility
- Local life-safety and fire code compliance
Door Hardware & I/O — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 532 working models of door hardware & i/o sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| Resolution | 8MP, 2MP |
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, Battery |
| Type | Accessory, Controller, Cable, Switch, Power Supply, Access Card, Contact, Lock/Strike |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.




