CyberPower PR3000LCDSL Pure Sinewave UPS
3000VA/2700W line-interactive UPS designed for critical IT infrastructure
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The CyberPower PR750LCDRT1U is a 750VA/600W line-interactive UPS designed for server closets, surveillance NVR installations, and network equipment stacks where clean, uninterrupted power is non-negotiable. This 1U rack-mount unit (or convertible tower) delivers pure sine wave output on both AC and battery power — critical for electronics that draw power conditioning-sensitive loads. The PR750LCDRT1U sits in the mid-range sweet spot: compact enough for tight rack spaces, capable enough to ride out brief facility power glitches and execute a graceful shutdown during extended outages.
The PR750LCDRT1U integrates with surveillance and IT infrastructure via SNMP monitoring (standard in Milestone XProtect, Genetec, and other enterprise NVR platforms), USB for direct system shutdown triggers, and relay contacts for third-party alarm/integration cabinets. PowerPanel Business Edition management software (included) runs on Windows and Linux, offering centralized UPS health dashboards across multiple units. Its 15 A circuit breaker and 10 ft NEMA 5-15P input cord suit standard electrical closets without requiring dedicated high-amperage feeds.
Input tolerance of 80–150 VAC (with line interactive AVR protection) means the unit operates in facilities with soft utility power or generator environments common in warehouse and distributed surveillance deployments. Operating temperature range of 32–104°F (0–40°C) covers typical data center and secure closet conditions; humidity tolerance to 95% non-condensing handles humid coastal or basement installations without derating. A $400,000 Connected Equipment Guarantee protects your downstream equipment in case of UPS failure.
The PR750LCDRT1U ships with a 10 ft NEMA 5-15P power cord, cables for USB/serial connectivity, and mounting hardware for 1U rack installation (or tower stand conversion). No batteries are sold separately — the unit arrives with its full four-cell 6V/7Ah sealed lead-acid battery string installed and charged to roughly 50%, requiring a brief charge cycle before first use.
Q: What's the warranty on the PR750LCDRT1U?
A: The PR750LCDRT1U includes a 3-Year Limited Warranty covering defects in materials and workmanship. Batteries typically degrade over 3–5 years depending on charge/discharge cycles and temperature; the warranty covers the battery for the full warranty period.
Q: Can I integrate the PR750LCDRT1U with my Milestone XProtect NVR?
A: Yes. The SNMP, USB, and relay connectivity enable integration with Milestone's management console for UPS health monitoring and graceful shutdown triggers. Your Milestone system can receive SNMP traps when the PR750LCDRT1U switches to battery, allowing automated recording prioritization or alert workflows.
Q: Is the PR750LCDRT1U suitable for a single-server or multi-camera NVR installation?
A: Yes, depending on load. A typical enterprise NVR (8-channel) draws 150–250W; this unit easily handles one or two modest NVRs plus network switching. If your NVR and network load exceed 300W, expect 10+ minutes of runtime; above 600W, you're at the ceiling and should consider a larger model or parallel-redundant units.
Q: What happens if I exceed 600W load?
A: The PR750LCDRT1U will not overload — it is circuit-protected at 15 A input. Sustained loads above 600W will cause the unit to shift to battery immediately and drain reserve quickly. Plan your rack load accordingly: UPS sizing is about sustained power, not peak.
Q: Does the PR750LCDRT1U support tower mounting?
A: Yes. The unit is convertible — remove the rack ears and use the included tower stand for floor or shelf installation. However, in a server room or closet, 1U rack mount is cleaner and takes less floor space.
Q: How often should I test the battery?
A: Most facilities recommend a quarterly load test (unplug AC, observe runtime under expected load) to confirm battery health. PowerPanel Business Edition can schedule automated tests and report results to your monitoring system.

I spec the PR750LCDRT1U into mid-tier NVR and network closets where the facility power is questionable — think warehouse distribution centers on aging electrical infrastructure or retail chains with frequent brownouts. The pure sine wave topology is the real differentiator here; it eliminates the risk of Active PFC power supply malfunction or early failure that plagued some deployments using offline UPS units. The 10 ms transfer time keeps your recording stream live through voltage sags that would trip a cheaper unit into battery.
Technical Highlights:
Deployment Considerations:
Deploy the PR750LCDRT1U when you're protecting a 1–2 NVR cluster plus edge switching in a facility with soft power or extended network importance. Pair it with quarterly runtime tests and a documented battery-swap schedule, and you've got a bulletproof failover foundation for the middle tier of surveillance infrastructure.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more CyberPower products? Shop the full CyberPower catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price