Middle Atlantic 6IN EVO Surface CVR Assy - 6CTC2BZ

Middle Atlantic 6CTC2BZ 6IN EVO Surface Cover AssemblyThe Middle Atlantic 6CTC2BZ is the surface-mount cover assembly for the 6CT Evolution poke-throu…

$493.40 $296.99 SAVE $196
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic 6IN EVO Surface CVR Assy - 6CTC2BZ

$493.40
$296.99

Overview

SKU: 6CTC2BZ
UPC: 786564088271
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic 6CTC2BZ 6IN EVO Surface Cover Assembly

The Middle Atlantic 6CTC2BZ is the surface-mount cover assembly for the 6CT Evolution poke-through device series — a finishing component that determines how connectivity points land in conference tables, executive desks, collaboration spaces, and AV presentation environments. If you're specifying or replacing the cover on a 6CT Evolution floor or table poke-thru, this is the part that closes out the installation and faces the end user every day.

Surface cover assemblies in the Middle Atlantic AV infrastructure line are purpose-built to pair with specific poke-through bodies. The 6CTC2BZ is not a universal fit — it is engineered for the 6CT Evolution series, so confirm your poke-through body model before ordering. Getting this right at specification time avoids a field trip back to swap out a mismatched cover.

Key Features

  • Surface Cover Style: The surface-mount configuration sits flush at tabletop or floor level without requiring a recessed cutout beyond what the poke-through body already occupies. This simplifies finish work in post-construction retrofits where slab depth is limited.
  • 7.25 in × 7.25 in Footprint: The square 7.25" × 7.25" (18.4 cm) cover plate accommodates the 6CT Evolution's outlet and connectivity cluster while keeping the surface profile manageable on standard conference tables. Verify your table substrate can accept this footprint before cutting.
  • 16.25 in Assembly Depth: At 16.25 in (41.3 cm) total depth, the assembly requires adequate clearance below the mounting surface — confirm floor plenum or table cavity depth before specifying. Shallow tables or raised-access floor tiles with limited plenum may need a different cover configuration.
  • Bronze Finish: The bronze color coordinates with premium furniture hardware common in boardrooms and executive suites. If your furniture spec calls for black or brushed nickel, cross-reference other 6CT Evolution cover SKUs — finish is the primary differentiator across the cover family.
  • Standard Receptacle Type: Accepts standard electrical receptacles, making it compatible with common North American outlet configurations. If you need USB-A/USB-C charging modules or HDMI/keystone inserts, confirm module compatibility with the 6CT Evolution body separately.
  • TAA Status — Not Compliant: The 6CTC2BZ is not TAA compliant. For federal installations, GSA schedules, or government-funded projects with TAA requirements, this cover cannot be specified. Select a TAA-compliant cover variant if your project requires it.

Integration and Compatibility

The 6CTC2BZ is designed for the Middle Atlantic 6CT Evolution poke-through device series. It is not a standalone product — it requires a compatible 6CT Evolution poke-through body for installation. When planning a deployment, verify the poke-through body model, confirm the table or floor substrate depth accommodates the 16.25 in assembly, and select the finish that matches your furniture specification. For projects involving AV infrastructure planning, review your AV mounting and infrastructure options to ensure the full system is coordinated. If you are deploying in a government or federally funded environment, note the TAA non-compliance and select an alternate SKU accordingly.

Frequently Asked Questions

Q: What poke-through body does the 6CTC2BZ work with?

A: The 6CTC2BZ is the surface cover assembly for the Middle Atlantic 6CT Evolution poke-through series. Confirm your poke-through body is in the 6CT Evolution family before ordering.

Q: Is the 6CTC2BZ TAA compliant?

A: No. The 6CTC2BZ is not TAA compliant. Federal, GSA, or government-funded projects with TAA requirements should select a compliant alternate cover SKU.

Q: What are the dimensions of the 6CTC2BZ cover plate?

A: The cover plate is 7.25 in × 7.25 in (18.4 cm × 18.4 cm) with a total assembly depth of 16.25 in (41.3 cm). Confirm your table or floor cavity provides adequate clearance for the full depth before installation.

Q: What finish color is the 6CTC2BZ?

A: Bronze. If your furniture spec requires black, nickel, or another finish, cross-reference other cover SKUs in the 6CT Evolution family.

Q: Does the 6CTC2BZ support USB or HDMI modules?

A: The 6CTC2BZ uses a standard receptacle type. Compatibility with USB, HDMI, or keystone insert modules depends on the 6CT Evolution poke-through body configuration — confirm module options with the body spec sheet before specifying.

Eden Phillips
Eden Phillips

The detail that catches integrators off-guard on the 6CTC2BZ is the 16.25 in assembly depth — that's over a foot of clearance required below the mounting surface. On a standard 1.25 in thick conference table, the poke-through body handles the penetration, but the full assembly still needs plenum or cavity space below. Specify this before the table is installed, not after.

Technical Highlights:

  • 7.25 in × 7.25 in Cover Plate: Square format fits the 6CT Evolution outlet cluster cleanly — no exposed gaps around the perimeter when installed on a correctly cut substrate.
  • 16.25 in Total Depth: Requires substantial below-surface clearance; raised-access floor tiles with shallow plenums may not accommodate the full assembly without a recessed alternative.
  • Bronze Finish: Matches premium furniture hardware in boardroom and executive suite environments — a visible component that end users interact with daily, so finish selection matters for client acceptance.

Deployment Considerations:

  • Always confirm the 6CT Evolution poke-through body model is on-hand before specifying the 6CTC2BZ — this cover is body-specific, not a universal fit across the Middle Atlantic poke-thru catalog.
  • TAA non-compliance is a hard stop for government and federally funded projects; flag this at the bid stage, not during submittal review.

The 6CTC2BZ is the right call for commercial conference room and boardroom buildouts where the 6CT Evolution body is already spec'd and bronze finish matches the furniture package — not a general-purpose cover for mixed or government environments.

Specifications
Depth: 16.25 in (41.3 cm)
Height: 7.25 in (18.4 cm)
Width: 7.25 in (18.4 cm)
Cover Style: Surface
Receptacle Type: Standard
Taa Compliant: No
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources