Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: PE6324LB
UPC: 672792402739
Condition: New
Write a Review 34% OFF

ATEN 30A/32A 24-OUTLET Metered & Switched LOW Profile ECO PDU - PE6324LB

ATEN PE6324LB 24-Outlet Metered & Switched Low-Profile Eco PDUOverviewThe ATEN PE6324LB is a rack-mount, 24-outlet metered and switched PDU design…

$1,021.00 $674.99 SAVE $346
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

ATEN 30A/32A 24-OUTLET Metered & Switched LOW Profile ECO PDU - PE6324LB

$1,021.00
$674.99

Overview

SKU: PE6324LB
UPC: 672792402739
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

ATEN PE6324LB 24-Outlet Metered & Switched Low-Profile Eco PDU

Overview

The ATEN PE6324LB is a rack-mount, 24-outlet metered and switched PDU designed for data center and server room environments where per-outlet power monitoring and remote switching control are operational requirements, not optional extras. Supporting both 30A and 32A input ratings and accepting input voltages across a wide 100VAC–250VAC range, the PE6324LB covers North American and international rack deployments from a single SKU — a practical advantage in mixed or globally standardized infrastructure. The low-profile form factor keeps rack space consumption minimal without sacrificing outlet density.

ATEN's ATEN PDU and power management line covers a broad range of metered, monitored, and switched configurations. The PE6324LB sits in the switched-and-metered tier of the rack PDU category, meaning you get both real-time consumption data and the ability to power-cycle individual outlets remotely — useful for hung servers, remote edge sites, or scheduled equipment cycling without a hands-on technician.

Key Features

  • Wide Input Voltage Acceptance (100VAC–250VAC ±1%): A single unit handles both North American 120V/208V circuits and international 230V installations. Voltage metering accuracy of ±1% means the readings you see on the management interface reflect actual line conditions — close enough for capacity planning and anomaly alerting without a separate power meter on the circuit.
  • Current Metering with Tiered Accuracy: Current is measured at ±0.1A for loads in the 0.1A–1A range, tightening to ±1% from 1A through 20A. In practice this means light-load standby monitoring is as accurate as full-load monitoring — relevant in mixed-density cabinets where some outlets carry UPS monitoring gear drawing under 1A alongside full servers drawing 10A+.
  • Power Range Metering (±2%): Watt-level power readings from 100W up to maximum capacity at ±2% tolerance. That granularity supports meaningful per-rack power trending in a power monitoring and capacity planning workflow — you are not estimating; you are measuring.
  • Per-Outlet Switching: 24 individually switched outlets let you power-cycle a locked-up device without touching adjacent equipment. In a remote colocation or unmanned edge environment, this eliminates a truck roll for a hard reboot — a recurring operational cost that per-outlet switching directly offsets.
  • Low-Profile Rack Form Factor: The low-profile mechanical design is suited to high-density cabinets where depth or clearance behind zero-U rails is constrained. Pair with appropriate rack PDU mounting accessories for zero-U or toolless rail installations.
  • 1.6m Power Cord: The factory-attached 1.6m cord reaches standard cabinet power strips or floor-mounted distribution panels in most standard 42U–48U rack depths without an extension. Verify against your specific cabinet depth and PDU mounting position before ordering.
  • Firmware Updateable (v1.5.146): Active firmware development — v1.5.146 released 2026-02-03 — means security patches and feature updates are available post-deployment. Updateable PDU firmware is a basic expectation in any managed data center environment, and ATEN maintains an active release cadence for this unit.
  • CE-LVD Safety Verification: Ships with CE Low Voltage Directive verification. Additional safety certifications are available by request — relevant for deployments with specific regional compliance requirements beyond CE.
  • 0–80% RH Non-Condensing Operating Humidity: Covers standard data center environmental ranges (ASHRAE A1/A2 class). Non-condensing spec means the unit handles normal HVAC fluctuations without concern for moisture-related faults.

Integration & Compatibility

The PE6324LB's wide voltage range makes it compatible with international power infrastructure. The unit supports firmware upgrades via the ATEN management interface, and environmental sensor support, SNMP/network management details, and NMS compatibility should be confirmed against the current ATEN product datasheet for this SKU before finalizing rack PDU selection for managed infrastructure deployments.

Frequently Asked Questions

Q: What is the input voltage range of the PE6324LB?

A: The PE6324LB accepts 100VAC to 250VAC input, making it suitable for both North American and international rack power environments.

Q: How accurate is the current metering on the PE6324LB?

A: Current metering accuracy is ±0.1A for loads between 0.1A and 1A, and ±1% for loads from 1A to 20A. Voltage metering is ±1% and power metering is ±2% of reading.

Q: Can I power-cycle individual outlets on the PE6324LB remotely?

A: Yes. The PE6324LB is a switched PDU with 24 individually controllable outlets, enabling remote power cycling of specific devices without affecting adjacent equipment.

Q: What firmware version ships with the PE6324LB?

A: The current firmware version is v1.5.146, released 2026-02-03, available as pe6324l-v1.5.146.zip from the ATEN support portal.

Q: What safety certifications does the PE6324LB carry?

A: The PE6324LB carries CE-LVD verification. Additional certifications are available by request according to ATEN documentation.

Q: How long is the power cord on the PE6324LB?

A: The factory-attached power cord is 1.6 meters (approximately 5.25 feet).

James Everett
James Everett

The PE6324LB is one of those rack PDUs where the metering accuracy tiers tell you more about real-world utility than the headline outlet count. The ±0.1A resolution at sub-1A loads means you are actually capturing meaningful data on lightweight devices — IPMI controllers, out-of-band management modules, environmental sensors — that would read as noise on a coarser meter. That granularity matters when you are baselining a dense cabinet and trying to distinguish idle draw from actual anomalies.

Technical Highlights:

  • Tiered Current Accuracy (±0.1A / ±1%): Sub-amp accuracy catches low-draw device anomalies that a ±2% meter would miss entirely — particularly useful in mixed-density cabinets with management hardware drawing under 500mA.
  • 100VAC–250VAC Input Range (±1% metering): A single SKU spans global voltage standards. For multi-region deployments or colocation facilities serving international tenants, this eliminates the need for region-specific PDU SKUs.
  • Active Firmware Cadence (v1.5.146, 2026-02-03): A firmware release in February 2026 indicates this unit is in active support. For managed infrastructure with security patching requirements, an actively maintained firmware chain is a baseline operational requirement.

Deployment Considerations:

  • The 1.6m cord fits most standard 42U rack deployments with overhead or floor-mount power distribution, but verify against your specific cabinet depth and zero-U versus horizontal mounting position before racking — cord reach is a common oversight that causes last-minute rewiring.
  • CE-LVD is the confirmed safety mark; if your deployment requires UL listing, FCC, or RoHS, contact ATEN to confirm availability for this specific SKU before purchase — the datasheet notes additional certifications are available by request, which means they are not all automatically included.

The PE6324LB is a solid fit for managed colocation cabinets and remote edge deployments where per-outlet switching eliminates truck rolls and tiered metering accuracy supports genuine capacity planning — not just approximate load monitoring.

Specifications
Mount Type: Rack
Function: PE6324LG
Metering Accuracy: Voltage Range: 100VAC ~ 250VAC +/-1%Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Power Cord Length: 1.6 m
Humidity (Operating & Storage: 0–80% RH, Non-Condensing
Safety Verification: CE-LVD, Others by Request
Firmware Upgrade: v1.5.146
s: Description
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources