ATEN 1U 20A 200-240V 16A MAX 7X C13 1X C19 PDU Metering & Switching - PE6208G

ATEN PE6208G 1U Metered & Switched 8-Outlet Rack PDUThe ATEN PE6208G is a 1U rack-mount power distribution unit designed for high-density server and n…

$708.00 $536.99 SAVE $171
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

ATEN 1U 20A 200-240V 16A MAX 7X C13 1X C19 PDU Metering & Switching - PE6208G

$708.00
$536.99

Overview

SKU: PE6208G
UPC: 672792401015
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

ATEN PE6208G 1U Metered & Switched 8-Outlet Rack PDU

The ATEN PE6208G is a 1U rack-mount power distribution unit designed for high-density server and network equipment environments running 200–240V infrastructure. With a 20A input rating and a 16A maximum load ceiling, the PE6208G delivers seven C13 outlets and one C19 outlet — a practical mix that covers both standard 1U/2U servers and the occasional high-draw device (storage arrays, large switches, UPS bypass loads) that demands a C19 connection. The 3-meter power cord gives you real reach in deep two-post or four-post racks without an extension, which matters in dense rows where outlet placement is rarely ideal.

Why Metering and Switching in the Same Unit

Rack PDUs split into three tiers: basic (strip power, no visibility), metered (read current draw), and metered-switched (read current draw and cut power per-outlet remotely). The PE6208G sits at the top tier. Per-outlet switching means you can remotely power-cycle a locked-up server, staggered-boot a rack to avoid inrush current spikes on startup, or isolate a faulty device without dispatching a technician to the data hall. That remote hands capability translates directly to reduced mean-time-to-resolution on equipment faults — a meaningful operational advantage for any managed colocation or remote-branch deployment.

Key Features

  • 8 Outlets (7× C13, 1× C19): The seven C13 outlets handle standard server and network gear while the single C19 supports higher-amperage devices up to the unit's 16A load ceiling — no need for a separate high-draw PDU in most mixed racks.
  • 20A Input / 16A Max Load: The 20A input with a 16A operational ceiling follows the 80% continuous-load rule for safe 24/7 operation without nuisance tripping — the standard conservative engineering practice for always-on data center environments.
  • 200–240V Input Range: Designed for international and domestic data center voltages (European 230V, international 220V/240V facilities), making the PE6208G deployable globally without voltage conversion hardware.
  • 3-Meter Power Cord: The included 3m cord covers the reach from a rack-mounted PDU to a floor PDU or overhead busway in most standard rack rows — eliminating the need for an additional extension in typical deployments.
  • Metering & Switching: Per-outlet power monitoring gives you real-time load visibility, while per-outlet switching enables remote power cycling — critical for lights-out facilities and remote branch equipment rooms.
  • SNMP & Network Management: Firmware version v2.5.248 (released 2026-04-15) is actively maintained. Compatible PMonitor software supports both Linux (v1.1) and Windows (v1.0.081) platforms, enabling integration into existing infrastructure monitoring workflows without additional licensing overhead.
  • UL Safety Verification: CE-LVD certification on the PE6208G (UL available on request) confirms the unit meets low-voltage directive safety standards — a basic procurement requirement for enterprise and institutional buyers.
  • 0–80% RH Non-Condensing Humidity Rating: Covers standard data center and equipment room humidity ranges (ASHRAE A1/A2 class environments) without active dehumidification requirements.

Integration & Compatibility

The PE6208G integrates with ATEN's PMonitor management software on both Linux and Windows, supporting centralized power monitoring across multiple PDU units in larger deployments. Explore the full ATEN rack power management line for complementary units including basic and metered-only variants that may fit lower-density or budget-constrained racks. For full rack power planning in high-density environments, pair this PDU with a compatible UPS and power protection solution to cover upstream failover. When specifying this unit alongside network infrastructure, review our PoE and managed switch catalog for the downstream devices this PDU will power. Buyers building out monitored server rooms should also consult a rack PDU selection guide to match outlet type, current capacity, and metering tier to actual load requirements before finalizing the unit count.

Frequently Asked Questions

Q: What is the maximum continuous load the PE6208G supports?

A: The PE6208G has a 20A input rating with a 16A maximum load — consistent with the 80% continuous-load rule for safe 24/7 data center operation.

Q: What outlet types does the PE6208G provide?

A: Seven IEC C13 outlets and one IEC C19 outlet, totaling eight outlets in a 1U form factor.

Q: What voltage range does the PE6208G support?

A: The PE6208G is rated for 200–240V input, covering standard international data center voltage ranges including 220V, 230V, and 240V facilities.

Q: What management software is compatible with the PE6208G?

A: ATEN's PMonitor software supports the PE6208G on both Linux (v1.1) and Windows (v1.0.081) platforms for centralized power monitoring.

Q: How long is the included power cord?

A: The PE6208G ships with a 3-meter power cord.

Q: What certifications does the PE6208G carry?

A: CE-LVD certification is standard on the PE6208G; UL certification is available by request.

Jerry Tildsen
Jerry Tildsen

The PE6208G is one of those PDUs I specify when a customer needs full outlet-level control in a 1U footprint on 200–240V infrastructure. The 16A maximum load ceiling is the spec I always flag first — on a 20A circuit that's exactly the 80% derate you want for continuous operation, and it means you need to be deliberate about load planning if you're populating all eight outlets with anything close to full-draw servers.

Technical Highlights:

  • CE-LVD Certification: Standard on the PE6208G with UL available on request — covers both European and North American procurement requirements without sourcing a separate region-specific SKU.
  • PMonitor Dual-OS Support: Linux v1.1 and Windows v1.0.081 clients mean you're not forced into a Windows-only management stack — relevant for Linux-heavy data center operations teams.
  • Firmware v2.5.248 (2026-04-15): Actively maintained firmware is a non-trivial point for switched PDUs — it confirms the unit is still in ATEN's support lifecycle, which matters for long-term rack deployments where PDU replacement mid-lease is disruptive.

Deployment Considerations:

  • The 3m cord is adequate for most two-post and four-post open racks, but verify your floor PDU or busway tap location before finalizing — enclosed cabinet designs with top-entry power sometimes need 4–5m to reach cleanly.
  • The 16A load cap with 8 outlets averages 2A per outlet at full saturation — run a load audit before deploying in a rack with multiple high-draw 1U servers to avoid hitting the ceiling during peak demand.

The PE6208G is the right call for managed colocation bays and remote equipment rooms where you need per-outlet remote cycling on 200–240V without deploying a full DCIM system — it handles the power visibility and control layer without adding infrastructure complexity.

Specifications
Mount Type: Rack
Function: PE6208A
Power Cord Length: 3 m
Humidity (Operating & Storage: 0 – 80% RH, Non-Condensing
Safety Verification: UL, Others by Request
Pe Snmp-S 2012-07-19.Pdf (1.27 Mb: 2012-07-19
Firmware Upgrade: v2.5.248
s: Description
Linux: PMonitor
Windows: PMonitor
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources