Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The ATEN PE6216G is a 1U rackmount power distribution unit engineered for 200–240V environments, delivering up to 16A across a mixed outlet bank of 14×C13 and 2×C15 receptacles. If you're provisioning power in a server room, AV rack, or surveillance head-end where European or international voltage standards apply, the PE6216G lands in the right power tier without oversizing your breaker budget. The TUV-CB and GOST safety certifications confirm this unit is designed for cross-border deployments — not just North American installs.
Unlike its sister variants, the PE6216A and PE6216B carry cTUVus and PSE marks for North American and Japanese markets respectively; the PE6216G is the internationally certified build in the same family, verified under TUV-CB and GOST. That distinction matters if you're integrating into a European or Russian-market facility where local compliance is audited.
The PE6216G fits into the broader ATEN intelligent PDU ecosystem, which includes SNMP-based remote monitoring and control capabilities documented in the pe_snmp-s firmware package. If your data center management or network monitoring platform uses SNMP polling for power visibility (outlet-level current, total load, environmental thresholds), confirm the MIB version against your NMS before deployment. The firmware upgrade path (v1.5.148 available as pe6216-v1.5.148.zip) is field-applicable, which means you can update in-place without returning the unit.
This unit is best paired with a managed rack switch and UPS on the same circuit leg — a common configuration in mid-size surveillance head-ends and edge server rooms where uptime accountability sits with the integrator rather than a data center ops team.
Q: What is the difference between the PE6216G and the PE6216A or PE6216B?
A: All three share the same 1U form factor, 16A/200–240V rating, 14×C13 + 2×C15 outlet layout, 3m cord, and firmware. The difference is safety certification: PE6216A carries cTUVus and PSE (North American and Japanese markets); PE6216B carries cTUVus and PSE; PE6216G carries TUV-CB and GOST, making it the correct variant for projects requiring European or Russian Federation compliance.
Q: Does the PE6216G support SNMP monitoring?
A: The ATEN PE6216 family supports SNMP-based management per the published pe_snmp-s firmware documentation. The PE6216G runs firmware v1.5.148 (May 2026). Confirm your NMS MIB compatibility before integrating into a production monitoring stack.
Q: Can the PE6216G be updated in the field?
A: Yes. Firmware v1.5.148 is available as a downloadable zip (pe6216-v1.5.148.zip, released 2026-05-29), and ATEN has maintained active firmware releases for this product line, so field upgrades are supported without returning the unit.
Q: What humidity range is the PE6216G rated for?
A: Operating and storage humidity is rated at 0–80% RH, non-condensing. It is not rated for condensing or outdoor environments.
Q: What outlet types does the PE6216G provide?
A: 14×IEC C13 and 2×IEC C15 outlets — 16 total. C13 handles standard server, switch, and networking loads; C15 accommodates devices requiring a higher-temperature cord rating.

The PE6216G is the variant to spec when your project crosses national borders — TUV-CB and GOST certification set it apart from the PE6216A and PE6216B, which cover North American and Japanese markets. For a European or multi-country rollout, pulling the wrong variant means a compliance gap that shows up at audit time, not install time.
Technical Highlights:
Deployment Considerations:
Best fit for international edge deployments — European branch offices, multi-region surveillance head-ends, or facilities in GOST-regulated markets where a single compliant PDU SKU simplifies procurement across locations.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more ATEN products? Shop the full ATEN catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price