Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2WG36TE-2CAF2M66/GR Switched 3-Branch PDU
Overview
The Server Technology C2WG36TE-2CAF2M66/GR is a switched Primary PRO2 power distribution unit built for data center racks that need outlet-level control across a mixed load of standard and high-density equipment. It pairs 24 C13 outlets with 12 CX ALT-BRANCH HDOT outlets on a 208V, 3-branch configuration, giving you both broad C13 coverage for general server and network gear and dedicated alternate-branch outlets for equipment that benefits from split-feed redundancy. TAA compliance makes the C2WG36TE-2CAF2M66/GR a straightforward fit for government and federal-adjacent procurement where sourcing documentation matters as much as the hardware spec.
Key Features
- 24 C13 Outlets: covers the majority of standard server, switch, and storage power cords without adapters — the outlet count most racks actually need for a full U-space buildout.
- 12 CX ALT-BRANCH HDOT Outlets: HDOT (High Density Outlet Technology) outlets on an alternate branch let you split critical loads across separate circuits, so a single breaker trip doesn't take down every device plugged into the rack.
- 208V Input: matches standard three-phase data center power infrastructure, letting this PDU sit in the same rack power plan as the rest of a commercial or enterprise deployment without a step-down.
- 3BR (3-Branch) Design: distributes the 36 total outlets across three separate circuit branches, so load balancing and breaker sizing follow the physical outlet groups rather than one shared circuit — useful when you're spec'ing circuit protection per branch.
- Switched Outlet Control: outlet-level switching (Primary PRO2 platform) supports remote power cycling of individual devices, which matters when a hung server or network appliance needs a hard reboot without a technician walking the row.
- TAA Compliance: qualifies the C2WG36TE-2CAF2M66/GR for federal and federal-contractor purchasing where Trade Agreements Act sourcing rules apply to the bill of materials.
Integration & Compatibility
The C2WG36TE-2CAF2M66/GR (often searched as C2WG36TE 2CAF2M66/GR) fits into standard rack power distribution planning alongside PDU and UPS equipment already in a deployment. Because it separates outlets across alternate branches, it pairs well in designs that also use rack servers requiring dual-corded, redundant-feed power. For teams planning a broader rack power layout, a PDU planning and rack power guide is worth reviewing before finalizing branch and breaker assignments — 36 outlets across 3 branches changes how you size upstream circuits compared to a single-branch unit. This model sits in the Server Technology Primary PRO2 switched PDU family; if your rack needs fewer alternate-branch outlets or a different C13/C-CX split, check the broader PDU lineup for a variant closer to that outlet mix.
Frequently Asked Questions
Q: Is the C2WG36TE-2CAF2M66/GR TAA compliant?
A: Yes, the C2WG36TE-2CAF2M66/GR is TAA compliant, making it eligible for federal and federal-contractor procurement that requires Trade Agreements Act sourcing.
Q: How many outlets does the C2WG36TE-2CAF2M66/GR have?
A: It has 36 total outlets: 24 C13 outlets plus 12 CX ALT-BRANCH HDOT outlets.
Q: What voltage does the C2WG36TE-2CAF2M66/GR run on?
A: It's rated for 208V input across a 3-branch (3BR) circuit configuration.
Q: What does ALT-BRANCH HDOT mean on this PDU?
A: The CX outlets are wired to an alternate branch circuit using Server Technology's HDOT (High Density Outlet Technology), allowing critical loads to be split across separate circuits for redundancy.
Q: Is this a switched PDU?
A: Yes, the C2WG36TE-2CAF2M66/GR is part of the Primary PRO2 switched PDU platform, supporting outlet-level power control.

The outlet split on the C2WG36TE-2CAF2M66/GR is what stands out to me — 24 C13 plus 12 CX ALT-BRANCH HDOT gives you room to run general rack gear off the main outlet bank while pulling redundancy-sensitive equipment onto the alternate branch.
Technical Highlights:
- 36 total outlets across 3 branches: a 3BR layout means each branch carries roughly a third of the outlet load, which simplifies breaker sizing when you're planning upstream circuit protection.
- 12 CX HDOT outlets on alt-branch: HDOT's high-density outlet spacing plus the alternate-branch wiring gives dual-corded gear a real second feed instead of sharing the same branch as everything else.
- 208V input: lines up with standard three-phase data center distribution, so it drops into existing rack power infrastructure without a transformer or step-down.
Deployment Considerations:
- Before ordering, confirm your rack's dual-corded equipment actually uses CX-style connectors on the redundant feed — the HDOT outlets are built for that connector family, not standard C14 plugs.
- 36 outlets across 3 branches means your upstream panel needs to support 3 separate circuit paths into the rack — plan breaker allocation before installation, not after.
This is a fit for a data center rack running a mix of single-corded C13 devices and a smaller set of redundancy-critical gear that needs an isolated alternate-branch feed — think a core network rack where a handful of dual-corded switches sit alongside a larger population of standard servers.
Compare with similar
Server Technology Switched Pops Primary - C2WG36TE-2CAF2M66/GR
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology